1994-05-27 12:33:43 +00:00
|
|
|
.\" Copyright (c) 1983, 1990, 1993
|
|
|
|
.\" The Regents of the University of California. All rights reserved.
|
|
|
|
.\"
|
|
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
|
|
.\" modification, are permitted provided that the following conditions
|
|
|
|
.\" are met:
|
|
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
|
|
.\" 3. All advertising materials mentioning features or use of this software
|
|
|
|
.\" must display the following acknowledgement:
|
|
|
|
.\" This product includes software developed by the University of
|
|
|
|
.\" California, Berkeley and its contributors.
|
|
|
|
.\" 4. Neither the name of the University nor the names of its contributors
|
|
|
|
.\" may be used to endorse or promote products derived from this software
|
|
|
|
.\" without specific prior written permission.
|
|
|
|
.\"
|
|
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
|
|
|
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
|
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
|
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
|
|
|
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
|
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
|
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
|
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
|
|
.\" SUCH DAMAGE.
|
|
|
|
.\"
|
|
|
|
.\" @(#)logger.1 8.1 (Berkeley) 6/6/93
|
1999-08-28 01:08:13 +00:00
|
|
|
.\" $FreeBSD$
|
1994-05-27 12:33:43 +00:00
|
|
|
.\"
|
|
|
|
.Dd June 6, 1993
|
|
|
|
.Dt LOGGER 1
|
2001-07-10 14:16:33 +00:00
|
|
|
.Os
|
1994-05-27 12:33:43 +00:00
|
|
|
.Sh NAME
|
|
|
|
.Nm logger
|
|
|
|
.Nd make entries in the system log
|
|
|
|
.Sh SYNOPSIS
|
1997-07-22 07:33:48 +00:00
|
|
|
.Nm
|
2000-12-18 08:37:53 +00:00
|
|
|
.Op Fl 46Ais
|
1994-05-27 12:33:43 +00:00
|
|
|
.Op Fl f Ar file
|
2000-07-18 08:56:54 +00:00
|
|
|
.Op Fl h Ar host
|
1994-05-27 12:33:43 +00:00
|
|
|
.Op Fl p Ar pri
|
|
|
|
.Op Fl t Ar tag
|
|
|
|
.Op Ar message ...
|
|
|
|
.Sh DESCRIPTION
|
|
|
|
.Nm Logger
|
|
|
|
provides a shell command interface to the
|
|
|
|
.Xr syslog 3
|
|
|
|
system log module.
|
|
|
|
.Pp
|
2000-03-26 14:39:03 +00:00
|
|
|
The following options are available:
|
|
|
|
.Bl -tag -width indent
|
2000-12-16 18:33:08 +00:00
|
|
|
.It Fl 4
|
|
|
|
Forces
|
|
|
|
.Nm
|
|
|
|
to use IPv4 addresses only.
|
|
|
|
.It Fl 6
|
|
|
|
Forces
|
|
|
|
.Nm
|
|
|
|
to use IPv6 addresses only.
|
|
|
|
.It Fl A
|
|
|
|
.Nm
|
|
|
|
tries to send the message to only one address
|
|
|
|
even if the host has more than one A or AAAA record.
|
|
|
|
If this option is specified,
|
|
|
|
.Nm
|
|
|
|
tries to send the message to all addresses.
|
1994-05-27 12:33:43 +00:00
|
|
|
.It Fl i
|
|
|
|
Log the process id of the logger process
|
|
|
|
with each line.
|
|
|
|
.It Fl s
|
|
|
|
Log the message to standard error, as well as the system log.
|
2001-07-15 08:06:20 +00:00
|
|
|
.It Fl f Ar file
|
1994-05-27 12:33:43 +00:00
|
|
|
Log the specified file.
|
2001-07-15 08:06:20 +00:00
|
|
|
.It Fl h Ar host
|
|
|
|
Send the message to the remote system
|
2000-07-18 08:56:54 +00:00
|
|
|
.Ar host
|
|
|
|
instead of logging it locally.
|
2001-07-15 08:06:20 +00:00
|
|
|
.It Fl p Ar pri
|
1994-05-27 12:33:43 +00:00
|
|
|
Enter the message with the specified priority.
|
|
|
|
The priority may be specified numerically or as a ``facility.level''
|
|
|
|
pair.
|
|
|
|
For example, ``\-p local3.info'' logs the message(s) as
|
|
|
|
.Ar info Ns rmational
|
|
|
|
level in the
|
|
|
|
.Ar local3
|
|
|
|
facility.
|
|
|
|
The default is ``user.notice.''
|
2001-07-15 08:06:20 +00:00
|
|
|
.It Fl t Ar tag
|
1994-05-27 12:33:43 +00:00
|
|
|
Mark every line in the log with the specified
|
|
|
|
.Ar tag .
|
|
|
|
.It Ar message
|
|
|
|
Write the message to log; if not specified, and the
|
|
|
|
.Fl f
|
|
|
|
flag is not
|
|
|
|
provided, standard input is logged.
|
|
|
|
.El
|
2000-03-26 14:39:03 +00:00
|
|
|
.Sh DIAGNOSTICS
|
2001-08-15 09:09:47 +00:00
|
|
|
.Ex -std
|
1994-05-27 12:33:43 +00:00
|
|
|
.Sh EXAMPLES
|
|
|
|
.Bd -literal -offset indent -compact
|
|
|
|
logger System rebooted
|
|
|
|
|
|
|
|
logger \-p local0.notice \-t HOSTIDM \-f /dev/idmc
|
|
|
|
.Ed
|
|
|
|
.Sh SEE ALSO
|
|
|
|
.Xr syslog 3 ,
|
|
|
|
.Xr syslogd 8
|
|
|
|
.Sh STANDARDS
|
|
|
|
The
|
1997-07-22 07:33:48 +00:00
|
|
|
.Nm
|
1994-05-27 12:33:43 +00:00
|
|
|
command is expected to be
|
|
|
|
.St -p1003.2
|
|
|
|
compatible.
|