1994-08-23 08:07:17 +00:00
|
|
|
.\" Copyright (c) 1986, 1991 The Regents of the University of California.
|
|
|
|
.\" All rights reserved.
|
1994-05-26 06:35:07 +00:00
|
|
|
.\"
|
|
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
|
|
.\" modification, are permitted provided that the following conditions
|
|
|
|
.\" are met:
|
|
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
|
|
.\" 3. All advertising materials mentioning features or use of this software
|
|
|
|
.\" must display the following acknowledgement:
|
|
|
|
.\" This product includes software developed by the University of
|
|
|
|
.\" California, Berkeley and its contributors.
|
|
|
|
.\" 4. Neither the name of the University nor the names of its contributors
|
|
|
|
.\" may be used to endorse or promote products derived from this software
|
|
|
|
.\" without specific prior written permission.
|
|
|
|
.\"
|
|
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
|
|
|
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
|
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
|
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
|
|
|
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
|
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
|
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
|
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
|
|
.\" SUCH DAMAGE.
|
|
|
|
.\"
|
1994-08-23 08:28:32 +00:00
|
|
|
.\" @(#)slattach.8 6.4 (Berkeley) 3/16/91
|
1994-05-26 06:35:07 +00:00
|
|
|
.\"
|
1994-08-23 08:28:32 +00:00
|
|
|
.\" $Header: /a/cvs/386BSD/src/sbin/slattach/slattach.8,v 1.6 1993/09/15 21:18:07 jkh Exp $
|
1994-08-23 08:07:17 +00:00
|
|
|
.\"
|
|
|
|
.Dd April 4, 1993
|
1994-05-26 06:35:07 +00:00
|
|
|
.Dt SLATTACH 8
|
|
|
|
.Os BSD 4.3
|
|
|
|
.Sh NAME
|
|
|
|
.Nm slattach
|
|
|
|
.Nd attach serial lines as network interfaces
|
1994-08-23 08:28:32 +00:00
|
|
|
.Sh SYNOPSIS
|
1994-05-26 06:35:07 +00:00
|
|
|
.Nm Slattach
|
1994-08-23 08:07:17 +00:00
|
|
|
.Op \-a
|
|
|
|
.Op \-c
|
|
|
|
.Op \-e exit-command
|
|
|
|
.Op \-f
|
|
|
|
.Op \-h
|
|
|
|
.Op \-l
|
|
|
|
.Op \-n
|
|
|
|
.Op \-r redial-command
|
|
|
|
.Op \-s baudrate
|
|
|
|
.Op \-u unit-command
|
|
|
|
.Op \-z
|
|
|
|
.Ar ttyname
|
1994-05-26 06:35:07 +00:00
|
|
|
.Sh DESCRIPTION
|
|
|
|
.Nm Slattach
|
|
|
|
is used to assign a tty line to a network interface,
|
|
|
|
and to define the network source and destination addresses.
|
|
|
|
The following operands are supported by
|
|
|
|
.Nm slattach :
|
|
|
|
.Bl -tag -width Ar
|
1994-08-23 08:07:17 +00:00
|
|
|
.It Ar \-a
|
|
|
|
Autoenable the VJ header compression option, if the other end of the link
|
|
|
|
is capable of VJ header compression then it will be used otherwise normal
|
|
|
|
headers will be used.
|
|
|
|
.It Ar \-c
|
|
|
|
Enables the VJ header compression option. Note that both ends of the link
|
|
|
|
must be able to use VJ header compression for this to work.
|
|
|
|
.It Ar \-e exit-command
|
|
|
|
Specifies a command to be invoked within a shell (sh -c exit-command)
|
|
|
|
before slattach exits.
|
|
|
|
.It Ar \-f
|
|
|
|
Disables the invocation of daemon() to run slattach in the background.
|
|
|
|
.It Ar \-h
|
|
|
|
Turn on cts/rts style flow control on the slip port, by default no flow
|
|
|
|
control is done.
|
|
|
|
.It Ar \-l
|
|
|
|
disable modem control (CLOCAL) and ignore carrier detect on the slip
|
|
|
|
port. By default the redial-command is invoked upon carrier drop and
|
|
|
|
slattach aborts if no redial-command is specified.
|
|
|
|
.It Ar \-n
|
|
|
|
Throw away ICMP packets. The slip interface will ignore ICMP packets
|
|
|
|
to prevent slow lines being saturated by ICMP responses.
|
|
|
|
.It Ar \-r redial-command
|
|
|
|
Specifies a command to be invoked within a shell (sh -c
|
|
|
|
redial-command) whenever carrier is lost on the line.
|
|
|
|
.It Ar \-s baudrate
|
|
|
|
Specifies the speed of the connection. If not specified, the
|
|
|
|
default of 9600 is used.
|
|
|
|
.It Ar \-u unit-command
|
|
|
|
When the line is switched to slip discipline, run
|
|
|
|
.Ql sh \-c unit-command <last> <current>
|
|
|
|
where <last> and <current> are the slip unit numbers when the line was
|
|
|
|
last opened and the unit number of the current slip connection
|
|
|
|
respecitvely. The unit number can change after redialing if you are
|
|
|
|
using more than one slip line. Slattach will abort if the unit number
|
|
|
|
changes and
|
|
|
|
.Ql \-u unit-command
|
|
|
|
was not specified.
|
|
|
|
.It Ar \-z
|
|
|
|
forces redial
|
|
|
|
redial-cmd upon startup irrespective of carrier.
|
1994-05-26 06:35:07 +00:00
|
|
|
.It Ar ttyname
|
|
|
|
Specifies the name of the tty device.
|
|
|
|
.Ar Ttyname
|
1994-08-23 08:07:17 +00:00
|
|
|
should be a string of the form
|
|
|
|
.Ql ttyXX or
|
|
|
|
.Ql /dev/ttyXX.
|
1994-05-26 06:35:07 +00:00
|
|
|
.El
|
|
|
|
.Pp
|
|
|
|
Only the super-user may attach a network interface.
|
|
|
|
.Pp
|
|
|
|
To detach the interface, use
|
|
|
|
.Dq Li ifconfig interface-name down
|
|
|
|
after killing off the
|
|
|
|
.Nm slattach
|
1994-08-23 08:07:17 +00:00
|
|
|
process using
|
|
|
|
.Ql kill -INT .
|
1994-05-26 06:35:07 +00:00
|
|
|
.Ar Interface-name
|
|
|
|
is the name that is shown by
|
|
|
|
.Xr netstat 1
|
1994-08-23 08:07:17 +00:00
|
|
|
.Pp
|
|
|
|
To setup slattach to redial the phone when carrier is lost, use the
|
|
|
|
.Ql \-r redial-cmd
|
|
|
|
option to specify a script or executable that will reconnect the
|
|
|
|
serial line to the slip server. For example, the script could redial
|
|
|
|
the server and log in, etc.
|
|
|
|
.Pp
|
|
|
|
To reconfigure the network interface in case the slip unit number
|
|
|
|
changes, use the
|
|
|
|
.Ql \-u unit-cmd
|
|
|
|
option to specify a script or executable that will be invoked as
|
|
|
|
.Ql sh \-c unit-cmd old new,
|
|
|
|
where old and new are the slip unit numbers before and after
|
|
|
|
reconnecting the line. The unit number can change if you have more
|
|
|
|
than one line disconnect at the same time. The first to succeed in
|
|
|
|
reconnecting will get the lowest unit number.
|
|
|
|
.Pp
|
|
|
|
To kill slattach use
|
|
|
|
.Ql kill -INT
|
|
|
|
(SIGINT) which causes it to close the tty and exit.
|
|
|
|
.Pp
|
|
|
|
To force a redial, use
|
|
|
|
.Ql kill -HUP
|
|
|
|
(SIGHUP) which causes slattach to think carrier was lost and thus invoke
|
|
|
|
.Ql sh -c redial-command
|
|
|
|
to reconnect to the server.
|
|
|
|
.Pp
|
|
|
|
If you use a hard-wired connection rather than a modem, invoke
|
|
|
|
slattach with the
|
|
|
|
.Ql \-l
|
|
|
|
option in order to ignore carrier on the slip line.
|
1994-05-26 06:35:07 +00:00
|
|
|
.Sh EXAMPLES
|
|
|
|
.Bd -literal -offset indent -compact
|
|
|
|
slattach ttyh8
|
1994-08-23 08:07:17 +00:00
|
|
|
slattach \-s 4800 /dev/tty01
|
|
|
|
slattach \-c \-s 38400 /dev/sio01
|
|
|
|
slattach \-r 'kermit -y dial.script >kermit.log 2>&1'
|
1994-05-26 06:35:07 +00:00
|
|
|
.Ed
|
|
|
|
.Sh DIAGNOSTICS
|
1994-08-23 08:07:17 +00:00
|
|
|
Look for error messages in /var/log/messages (slattach is a daemon).
|
1994-05-26 06:35:07 +00:00
|
|
|
Messages indicating the specified interface does not exit, the
|
1994-08-23 08:07:17 +00:00
|
|
|
requested address is unknown, the user is not privileged and tried to
|
|
|
|
alter an interface's configuration are logged there. Slattach also
|
|
|
|
logs failure to set the controlling terminal or failure to install
|
|
|
|
signal handlers. Upon connection and redial the ttyname and baud rate
|
|
|
|
are logged and on shutdown the ttyname is logged.
|
|
|
|
.Pp
|
1994-05-26 06:35:07 +00:00
|
|
|
.Sh SEE ALSO
|
|
|
|
.Xr netstat 1 ,
|
|
|
|
.Xr netintro 4 ,
|
|
|
|
.Xr ifconfig 8 ,
|
|
|
|
.Xr rc 8
|
|
|
|
.Sh HISTORY
|
|
|
|
The
|
|
|
|
.Nm
|
|
|
|
command appeared in
|
|
|
|
.Bx 4.3 .
|