.\" Copyright (c) 1983, 1993
|
||
|
.\" The Regents of the University of California. All rights reserved.
|
||
|
.\"
|
||
|
.\" Redistribution and use in source and binary forms, with or without
|
||
|
.\" modification, are permitted provided that the following conditions
|
||
|
.\" are met:
|
||
|
.\" 1. Redistributions of source code must retain the above copyright
|
||
|
.\" notice, this list of conditions and the following disclaimer.
|
||
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
||
|
.\" notice, this list of conditions and the following disclaimer in the
|
||
|
.\" documentation and/or other materials provided with the distribution.
|
||
|
.\" 3. All advertising materials mentioning features or use of this software
|
||
|
.\" must display the following acknowledgement:
|
||
|
.\" This product includes software developed by the University of
|
||
|
.\" California, Berkeley and its contributors.
|
||
|
.\" 4. Neither the name of the University nor the names of its contributors
|
||
|
.\" may be used to endorse or promote products derived from this software
|
||
|
.\" without specific prior written permission.
|
||
|
.\"
|
||
|
.\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
|
||
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
||
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
||
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
|
||
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
||
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
||
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
||
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
||
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
||
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
||
|
.\" SUCH DAMAGE.
|
||
|
.\"
|
||
|
.\" @(#)6.t 8.1 (Berkeley) 6/8/93
|
||
|
.\"
|
||
|
.\".ds RH "Adding New Devices
|
||
|
.ne 2i
|
||
|
.NH
|
||
|
ADDING NEW SYSTEM SOFTWARE
|
||
|
.PP
|
||
|
This section is not for the novice, it describes
|
||
|
some of the inner workings of the configuration process as
|
||
|
well as the pertinent parts of the system autoconfiguration process.
|
||
|
It is intended to give
|
||
|
those people who intend to install new device drivers and/or
|
||
|
other system facilities sufficient information to do so in the
|
||
|
manner which will allow others to easily share the changes.
|
||
|
.PP
|
||
|
This section is broken into four parts:
|
||
|
.IP \(bu 3
|
||
|
general guidelines to be followed in modifying system code,
|
||
|
.IP \(bu 3
|
||
|
how to add non-standard system facilities to 4.4BSD,
|
||
|
.IP \(bu 3
|
||
|
how to add a device driver to 4.4BSD, and
|
||
|
.NH 2
|
||
|
Modifying system code
|
||
|
.PP
|
||
|
If you wish to make site-specific modifications to the system
|
||
|
it is best to bracket them with
|
||
|
.DS
|
||
|
#ifdef SITENAME
|
||
|
\&...
|
||
|
#endif
|
||
|
.DE
|
||
|
to allow your source to be easily distributed to others, and
|
||
|
also to simplify \fIdiff\fP\|(1) listings. If you choose not
|
||
|
to use a source code control system (e.g. SCCS, RCS), and
|
||
|
perhaps even if you do, it is
|
||
|
recommended that you save the old code with something
|
||
|
of the form:
|
||
|
.DS
|
||
|
#ifndef SITENAME
|
||
|
\&...
|
||
|
#endif
|
||
|
.DE
|
||
|
We try to isolate our site-dependent code in individual files
|
||
|
which may be configured with pseudo-device specifications.
|
||
|
.PP
|
||
|
Indicate machine-specific code with ``#ifdef vax'' (or other machine,
|
||
|
as appropriate).
|
||
|
4.4BSD underwent extensive work to make it extremely portable to
|
||
|
machines with similar architectures\- you may someday find
|
||
|
yourself trying to use a single copy of the source code on
|
||
|
multiple machines.
|
||
|
.NH 2
|
||
|
Adding non-standard system facilities
|
||
|
.PP
|
||
|
This section considers the work needed to augment
|
||
|
.IR config 's
|
||
|
data base files for non-standard system facilities.
|
||
|
.I Config
|
||
|
uses a set of files that list the source modules that may be required
|
||
|
when building a system.
|
||
|
The data bases are taken from the directory in which
|
||
|
.I config
|
||
|
is run, normally /sys/conf.
|
||
|
Three such files may be used:
|
||
|
.IR files ,
|
||
|
.IR files .machine,
|
||
|
and
|
||
|
.IR files .ident.
|
||
|
The first is common to all systems,
|
||
|
the second contains files unique to a single machine type,
|
||
|
and the third is an optional list of modules for use on a specific machine.
|
||
|
This last file may override specifications in the first two.
|
||
|
The format of the
|
||
|
.I files
|
||
|
file has grown somewhat complex over time. Entries are normally of
|
||
|
the form
|
||
|
.IP
|
||
|
.nf
|
||
|
.DT
|
||
|
\fIdir/source.c\fP \fItype\fP \fIoption-list\fP \fImodifiers\fP
|
||
|
.LP
|
||
|
for example,
|
||
|
.IP
|
||
|
.nf
|
||
|
.DT
|
||
|
\fIvaxuba/foo.c\fP \fBoptional\fP foo \fBdevice-driver\fP
|
||
|
.LP
|
||
|
The
|
||
|
.I type
|
||
|
is one of
|
||
|
.B standard
|
||
|
or
|
||
|
.BR optional .
|
||
|
Files marked as standard are included in all system configurations.
|
||
|
Optional file specifications include a list of one or more system
|
||
|
options that together require the inclusion of this module.
|
||
|
The options in the list may be either names of devices that may
|
||
|
be in the configuration file,
|
||
|
or the names of system options that may be defined.
|
||
|
An optional file may be listed multiple times with different options;
|
||
|
if all of the options for any of the entries are satisfied,
|
||
|
the module is included.
|
||
|
.PP
|
||
|
If a file is specified as a
|
||
|
.IR device-driver ,
|
||
|
any special compilation options for device drivers will be invoked.
|
||
|
On the VAX this results in the use of the
|
||
|
.B \-i
|
||
|
option for the C optimizer. This is required when pointer references
|
||
|
are made to memory locations in the VAX I/O address space.
|
||
|
.PP
|
||
|
Two other optional keywords modify the usage of the file.
|
||
|
.I Config
|
||
|
understands that certain files are used especially for
|
||
|
kernel profiling. These files are indicated in the
|
||
|
.I files
|
||
|
files with a
|
||
|
.I profiling-routine
|
||
|
keyword. For example, the current profiling subroutines
|
||
|
are sequestered off in a separate file with the following
|
||
|
entry:
|
||
|
.IP
|
||
|
.nf
|
||
|
.DT
|
||
|
\fIsys/subr_mcount.c\fP \fBoptional\fP \fBprofiling-routine\fP
|
||
|
.fi
|
||
|
.LP
|
||
|
The
|
||
|
.I profiling-routine
|
||
|
keyword forces
|
||
|
.I config
|
||
|
not to compile the source file with the
|
||
|
.B \-pg
|
||
|
option.
|
||
|
.PP
|
||
|
The second keyword which can be of use is the
|
||
|
.I config-dependent
|
||
|
keyword. This causes
|
||
|
.I config
|
||
|
to compile the indicated module with the global configuration
|
||
|
parameters. This allows certain modules, such as
|
||
|
.I machdep.c
|
||
|
to size system data structures based on the maximum number
|
||
|
of users configured for the system.
|
||
|
.NH 2
|
||
|
Adding device drivers to 4.4BSD
|
||
|
.PP
|
||
|
The I/O system and
|
||
|
.I config
|
||
|
have been designed to easily allow new device support to be added.
|
||
|
The system source directories are organized as follows:
|
||
|
.DS
|
||
|
.TS
|
||
|
lw(1.0i) l.
|
||
|
/sys/h machine independent include files
|
||
|
/sys/sys machine-independent system source files
|
||
|
/sys/conf site configuration files and basic templates
|
||
|
/sys/net network-protocol-independent, but network-related code
|
||
|
/sys/netinet DARPA Internet code
|
||
|
/sys/netimp IMP support code
|
||
|
/sys/netns Xerox NS code
|
||
|
/sys/vax VAX-specific mainline code
|
||
|
/sys/vaxif VAX network interface code
|
||
|
/sys/vaxmba VAX MASSBUS device drivers and related code
|
||
|
/sys/vaxuba VAX UNIBUS device drivers and related code
|
||
|
.TE
|
||
|
.DE
|
||
|
.PP
|
||
|
Existing block and character device drivers for the VAX
|
||
|
reside in ``/sys/vax'', ``/sys/vaxmba'', and ``/sys/vaxuba''. Network
|
||
|
interface drivers reside in ``/sys/vaxif''. Any new device
|
||
|
drivers should be placed in the appropriate source code directory
|
||
|
and named so as not to conflict with existing devices.
|
||
|
Normally, definitions for things like device registers are placed in
|
||
|
a separate file in the same directory. For example, the ``dh''
|
||
|
device driver is named ``dh.c'' and its associated include file is
|
||
|
named ``dhreg.h''.
|
||
|
.PP
|
||
|
Once the source for the device driver has been placed in a directory,
|
||
|
the file ``/sys/conf/files.machine'', and possibly
|
||
|
``/sys/conf/devices.machine'' should be modified. The
|
||
|
.I files
|
||
|
files in the conf directory contain a line for each C source or binary-only
|
||
|
file in the system. Those files which are machine independent are
|
||
|
located in ``/sys/conf/files,'' while machine specific files
|
||
|
are in ``/sys/conf/files.machine.'' The ``devices.machine'' file
|
||
|
is used to map device names to major block device numbers. If the device
|
||
|
driver being added provides support for a new disk
|
||
|
you will want to modify this file (the format is obvious).
|
||
|
.PP
|
||
|
In addition to including the driver in the
|
||
|
.I files
|
||
|
file, it must also be added to the device configuration tables. These
|
||
|
are located in ``/sys/vax/conf.c'', or similar for machines other than
|
||
|
the VAX. If you don't understand what to add to this file, you should
|
||
|
study an entry for an existing driver.
|
||
|
Remember that the position in the
|
||
|
device table specifies the major device number.
|
||
|
The block major number is needed in the ``devices.machine'' file
|
||
|
if the device is a disk.
|
||
|
.PP
|
||
|
With the configuration information in place, your configuration
|
||
|
file appropriately modified, and a system reconfigured and rebooted
|
||
|
you should incorporate the shell commands needed to install the special
|
||
|
files in the file system to the file ``/dev/MAKEDEV'' or
|
||
|
``/dev/MAKEDEV.local''. This is discussed in the document ``Installing
|
||
|