as clean on shutdown and move that action from shutdown_pre_sync stage to
shutdown_post_sync to avoid extra flapping.
ZFS tends to not close devices on shutdown, that doesn't allow GEOM RAID
to shutdown gracefully. To handle that, mark volume as clean just when
shutdown time comes and there are no active writes.
PR: kern/113957
MFC after: 2 weeks
bytes syncronized.
The rationale behind this is the following: for large disks the
percent synchronisation counter ticks too seldom, and monitoring
software (as well as human operator) can't tell whether
synchronisation goes on or one of disks got stuck. On an idle
server one can look into gstat and see whether synchronisation goes
on or not, but on a busy server that won't work. Also, new value
monitored can be differentiated obtaining the synchronisation speed
quite precisely.
Submitted by: Konstantin Kukushkin <dark ramtel.ru>
Reviewed by: pjd
we need to pass BIO_DELETE requests down to providers that support
it. Also, we need to announce our support for BIO_DELETE to upper
consumer. This requires:
- In g_mirror_start() return true for "GEOM::candelete" request.
- In g_mirror_init_disk() probe below provider for "GEOM::candelete"
attribute, and mark disk with a flag if it does support BIO_DELETE.
- In g_mirror_register_request() distribute BIO_DELETE requests only
to those disks, that do support it.
Note that we announce "GEOM::candelete" as true unconditionally of
whether we have TRIM-capable media down below or not. This is made
intentionally, because upper consumer (usually UFS) requests the
attribite only once at mount time. And if user ever migrates his
mirror from HDDs to SSDs, then he/she would get TRIM working without
remounting filesystem.
Reviewed by: pjd
The SYSCTL_NODE macro defines a list that stores all child-elements of
that node. If there's no SYSCTL_DECL macro anywhere else, there's no
reason why it shouldn't be static.
No FreeBSD version bump, the userland application to query the features will
be committed last and can serve as an indication of the availablility if
needed.
Sponsored by: Google Summer of Code 2010
Submitted by: kibab
Reviewed by: silence on geom@ during 2 weeks
X-MFC after: to be determined in last commit with code from this project
- Instead of measuring last request execution time for each drive and
choosing one with smallest time, use averaged number of requests, running
on each drive. This information is more accurate and timely. It allows to
distribute load between drives in more even and predictable way.
- For each drive track offset of the last submitted request. If new request
offset matches previous one or close for some drive, prefer that drive.
It allows to significantly speedup simultaneous sequential reads.
PR: kern/113885
Reviewed by: sobomax
to kproc_xxx as they actually make whole processes.
Thos makes way for us to add REAL kthread_create() and friends
that actually make theads. it turns out that most of these
calls actually end up being moved back to the thread version
when it's added. but we need to make this cosmetic change first.
I'd LOVE to do this rename in 7.0 so that we can eventually MFC the
new kthread_xxx() calls.
- Use thread_lock() rather than sched_lock for per-thread scheduling
sychronization.
- Use the per-process spinlock rather than the sched_lock for per-process
scheduling synchronization.
Tested by: kris, current@
Tested on: i386, amd64, ULE, 4BSD, libthr, libkse, PREEMPTION, etc.
Discussed with: kris, attilio, kmacy, jhb, julian, bde (small parts each)
gmirror and graid3 in a way that it is not resynchronized after a
power failure or system crash.
It is safe when gjournal is running on top of gmirror/graid3.
request can still have bio_to set to sc_provider (this is READ part of a
synchronization request) and in this case g_{mirror,raid3}_sync() wasn't
called as it should be.
MFC after: 1 week
add count of active and total components to the launched line so you can
see at a glance if your mirror/raid3 is complete...
now:
GEOM_MIRROR: Device mirror/sam launched (2/2).
Reviewed by: pjd
- Comment possible event miss, which isn't critical, but probably can be
fixed by replacing the event lock usage with the queue lock.
MFC after: 2 weeks
which means that devices will be destroyed on last close.
This fixes destruction order problems when, eg. RAID3 array is build on
top of RAID1 arrays.
Requested, reviewed and tested by: ru
MFC after: 2 weeks
requests in parallel.
+ Add kern.geom.mirror.sync_requests tunable which defines how many parallel
I/O requests should be used.
+ Retire kern.geom.mirror.reqs_per_sync and kern.geom.mirror.syncs_per_sec
sysctls.
- Fix race between regular and synchronization requests.
- Reimplement mirror's data synchronization - do not use the topology lock
for this purpose, as it may case deadlocks.
- Stop synchronization from pre-sync hook.
- Fix some other minor issues.
MFC after: 3 days
means that old problem was triggered (when two providers end at the same
offset, eg. ad0 and ad0s1 and the wrong was is picked up by gmirror/graid3).
Reported by: Michal Suszko <dry@dry.pl>
MFC after: 3 days
to preserve currect behaviour). When set to 0, components are not
disconnected - gmirror will try to still use them (only first error will
be logged). This is helpful when we have two broken components, but in
different places, so actually all data is available.
Such buggy component will be visible in 'gmirror list' output with flag
BROKEN.
- Never disconnect the last valid component. If we detect errors there we
will just pass them up. This wasn't reasonable to deny access to the
whole provider because of one broken sector.
Prodded by: ru
MFC after: 3 days
o The only indication of error condition is NULL value returned by
the function;
o value pointed to by error argument is undefined in the case when
operation completes successfully.
Discussed with: phk
- Prefer '_' to ' ', as it results in more easily parsed results in
memory monitoring tools such as vmstat.
- Remove punctuation that is incompatible with using memory type names
as file names, such as '/' characters.
- Disambiguate some collisions by adding subsystem prefixes to some
memory types.
- Generally prefer lower case to upper case.
- If the same type is defined in multiple architecture directories,
attempt to use the same name in additional cases.
Not all instances were caught in this change, so more work is required to
finish this conversion. Similar changes are required for UMA zone names.