there is some hope for the 32-bit management utilities to run. I've used
the cli successfully, but 3dm2 doesn't work for other reasons. Of course,
a native binary of the 3dm2 and cli would be much better, but that doesn't
exist.
issues which they found and asked to be changed so 3ware can offcially
support the driver.
Summary of the most significant changes:
- TWE_OVERRIDE is no longer supported
- If twe_getparam failed, bogus data would be returned to the caller
- Cache the device unit in the twe_drive structure to aid debugging
- Add the 3ware driver version.
- Proper return error codes for many functions.
- Track the minimum queue length statistics
- 4.x compat: use the cached unit number from the twe_drive structure
instead of the the cached si_drv2. 3ware found that after many loads
and unloads that si_drv2 became corrupted. This did not happen in
-current.
Submitted by: Vinod Kashyap (with modifications by me)
Approved by: re (rwatson)
- Build SGL's for ATA_PASSTHROUGH commands
- Fallback to using the sgl_offset when the opcode is unknown for building
SGL's/
- Add ioctl calls for adding and removing units.
- Define previously undefined AEN's
- Allocate memory for the ioctl payload in multiples of 512bytes.
MFC after: 1 week
- Layout reorganisation to enhance portability. The driver now has
a relatively MI 'core' and a FreeBSD-specific layer over the top.
Since the NetBSD people have already done their own port, this is
largely just to help me with the BSD/OS port.
- Request ID allocation changed to improve performance (I'd been
considering switching to this approach after having failed to come
up with a better way to dynamically allocate request IDs, and seeing
Andy Doran use it in the NetBSD port of the driver convinced me
that I was wasting my time doing it any other way). Now we just
allocate all the requests up front.
- Maximum request count bumped back to 255 after characterisation
of a firmware issue (off-by-one causing it to crash with 256
outstanding commands).
- Control interface implemented. This allows 3ware's '3dm' utility to
talk to the controller. 3dm will be available from 3ware shortly.
- Controller soft-reset feature added; if the controller signals a
firmware or protocol error, the controller will be reset and all
outstanding commands will be retried.