output to setproctitle(3) in order to get rid of the ugly two-character
escape sequence "\n" in the ps(1) output of a dump(8) process:
<< [...] finished in 0:00 at Sat Aug 5 14:44:39 2006\n (dump)
>> [...] finished in 0:00 at Sat Aug 5 14:44:39 2006 (dump)
init(8), to avoid losing a race to them and dying before being able
to call reboot(2).
PR: bin/64664
Submitted by: maxim
Obtained from: NetBSD
MFC after: 30 days
code independent of the macro. This utility is just omitted
from the build as a whole by ../Makefile if MK_INET6 is set to false.
Pointed out by: ume
Tested with: cmp(1)
not be mounted unless the -l flag was specified.
Add an rc script, mountlate, which basically runs 'mount -a -l'. It runs
after DAEMON but before LOGIN.
This is useful for things like loopback mounts, because mountcritremote
runs before mountd / nfsd (since /usr might be a remote file system), so
an attempt to mount a loopback network file system in mountcritremote will
fail.
Also add a progress message to mountcritlocal, for the sake of symmetry
with similar messages in mountcritremote and mountlate.
Reviewed by: freebsd-rc
MFC after: 3 weeks
mechanism
o change vlan cloning to use callback and pass all vlan parameters
on create using the new SIOCREATE2 ioctl
o update vlan set logic to match existing practice
with NACK if I don't set it. Setting 'option dhcp-client-identifier' is
alternative but it is inconvenient because I have to keep the list of
all MAC addresses. As bin/94743 pointed out, it is always sent from
Windows clients and I found Mac OS X does the same.
OK'd by: brooks
order to - for example - apply firewall rules to a whole group of
interfaces. This is required for importing pf from OpenBSD 3.9
Obtained from: OpenBSD (with changes)
Discussed on: -net (back in April)
sector size, instead of later failing with an error about /boot/mbr
not being a multiple of the sector size (since we end up with an
assumed sector size of MAX_SEC_SIZE * 2).
- We query the sector size via an IOCTL anyway, so if that succeeds
use that instead of probing for it via read(2) calls. This fixes
the problem with fdisk failing to operate on at least graid3 and
md(4) devices on kernels with src/sys/geom/geom_dev.c before
rev. 1.90, due to fdisk failing to detect the sector size.
- When detecting the root device allow "/" characters in it, which
happens with e.g. gmirror devices.
Reviewed by: cperciva
MFC after: 1 week
- 'tag' & 'untag' action parameters.
- 'tagged' & 'limit' rule options.
Rule examples:
pipe 1 tag tablearg ip from table(1) to any
allow ip from any to table(2) tagged tablearg
allow tcp from table(3) to any 25 setup limit src-addr tablearg
sbin/ipfw/ipfw2.c:
1) new macros
GET_UINT_ARG - support of 'tablearg' keyword, argument range checking.
PRINT_UINT_ARG - support of 'tablearg' keyword.
2) strtoport(): do not silently truncate/accept invalid port list expressions
like: '1,2-abc' or '1,2-3-4' or '1,2-3x4'. style(9) cleanup.
Approved by: glebius (mentor)
MFC after: 1 month
keeping a flag to check whether we actually wanted to mount the filesystem
readonly, setup the options list so that we start off by assuming rw is what's
desired and let later flags change that.
to the init. This prevents zombies from being accumulated.
PR: bin/64198
Tested by: Eugene Grosbein <eugen at www svzserv kemerovo su>
Approved by: kan (mentor)
MFC after: 1 month
Now, encryption algorithm is given using '-e' option, not '-a'.
The '-a' option is now used to specify authentication algorithm.
Supported by: Wheel Sp. z o.o. (http://www.wheel.pl)
- remove call to getmntopts(), and just pass -o options to
nmount(). This removes some confusion as to what options
msdosfs can parse, by pushing the responsibility of option parsing
to the VFS and FS specific code in the kernel.
msdosfs_vfsops.c:
- add "force" and "sync" to msdosfs_opts. They used to be specified
in mount_msdosfs.c, so move them here. It's not clear whethere these
options should be placed into global_opts in vfs_mount.c or not.
Motivated by: marcus
Since tags are kept while packet resides in kernelspace, it's possible to
use other kernel facilities (like netgraph nodes) for altering those tags.
Submitted by: Andrey Elsukov <bu7cher at yandex dot ru>
Submitted by: Vadim Goncharov <vadimnuclight at tpu dot ru>
Approved by: glebius (mentor)
Idea from: OpenBSD PF
MFC after: 1 month
It is no longer needed, because "mount -t reiserfs" calls nmount(2)
directly to mount a ReiserFS file system without the use of
this external mount program.
Approved by: dumbbell
option if none is given in the config file. Also add #ifdefd out
support for sending a client ID based on our MAC address.
PR: bin/94743, bin/76401
Submitted by: Frank Behrens <frank at pinky dot sax dot de>
X-MFC after: 6.1-RELEASE
o Introduce -r and -w keys which allow to load and save a worklist.
o Replace README by man page.
PR: bin/96677
Submitted by: Ulrich Spoerlein
Approved by: phk
MFC after: 1 month
arguments so we do not coredump at "help foo", "back bar" and such.
o Be consistent and print argc - 1 as a command arguments number in
all cases.
PR: bin/37096
Submitted by: Joshua Goodall
MFC after: 1 month
Reset it to 1 for each devd config file so if the parser finds
a syntax error devd(8) will report a correct line number.
Submitted by: Niki Denev
MFC after: 2 weeks
to match the number of inodes on the disk. If we find a directory
entry with a crazy inode number in it, don't look beyond the end
of the bitmap to find that inode's state. Instead skip that directory
entry and print a warning.
Reviewed by: iedowse
MFC after: 3 weeks
wait time for a packet. This allows to:
- Count number of packets received before and after specified
time.
- Shorten time of execution of 'ping -c 1' scripts.
Submitted by: Lytochkin Boris <lytboris gmail.com>
device number at creation time with -u option. Together with XMLizing
mdconfig(8), I broke this functionality.
This change is temporary. Complete fix will be commited soon.
Approved by: cognet (mentor)
a problem with listing large number of md(4) devices. Either 'list' or
'query' mode uses XML.
Additionally, new functionality was introduced. It's possible to pass
multiple devices to -u:
# ./mdconfig -l -u md0,md1
Approved by: cognet (mentor)
- <netipx> headers [1]
- IPX library (libipx)
- IPX support in ifconfig(8)
- IPXrouted(8)
- new MK_NCP option
New MK_NCP build option controls:
- <netncp> and <fs/nwfs> headers
- NCP library (libncp)
- ncplist(1) and ncplogin(1)
- mount_nwfs(8)
- ncp and nwfs kernel modules
User knobs: WITHOUT_IPX, WITHOUT_IPX_SUPPORT, WITHOUT_NCP.
[1] <netsmb/netbios.h> unconditionally uses <netipx> headers
so they are still installed. This needs to be dealt with.