/var/log/vinum_history. Also check that any existing history file is
a regular file.
Admonished-by: imp
Allow stopping long-running commands with ^C (well, SIGINTR).
Previously this would stop the program.
directly off the drives.
This command shows a minor problem: it requires that the device nodes
exist, whereas kernel Vinum does not. Thus dumpconfig may show no
configuration for certain drives which are up and happily running.
This is documented in the man page.
Describe -i option for start.
Update description of start command (will now work on plexes).
Update discussion of choice of stripe size (don't use power of 2).
Remove references to raw devices.
Add -i option to delay between blocks copied, to reduce performance
impact.
Remove -v option, things work now.
Rewrite parity maintenance functions.
Rebuildparity: Add -v option to check whether it was broken before
rebuilding each block.
Describe stop -f to stop when config updates are disabled.
Explain in more detail why Vinum needs its own partition type, and why
you can't make it the c partition.
Implicitly-sanctioned-by: jkh
replaces an older attempt to silence vinum(8) when started in
single-user mode.
Add entries for vinum_raid[45].
Replace the preprocessor variable name CDEV_MAJOR with
VINUM_CDEV_MAJOR.
continue_revive: Set the proc title to 'reviving <sdname>' so that it
can be recognized in a ps list.
Approved-by: jkh
drive if it is set.
vinum_lvi: Change line spacing. This is still not right.
Change checks for striped or RAID-5 plexes to a macro 'isstriped',
which now also includes RAID-4.
Change checks for RAID-5 plexes to a macro 'isparity', which now also
includes RAID-4.
vinum_lsi: If the subdisk is initializing or reviving, don't wait a
whole second to check whether it's advancing; wait in increments of 50
ms up to 1 second. This makes for a barely perceptible delay.
Approved-by: jkh
enabled and print a warning message in varous places if they are not.
Fix typos in comments.
Change some indents to approach style(9).
initvol: If init fails, place the subdisks in a "down" state.
vinum_start(): If we're starting a plex, try doing it directly. It's
possible that the state of the plex differs from that of the subdisks,
for example if somebody has used 'setupstate'.
New functions vinum_raid4 and vinum_raid5 to create RAID-4 and RAID-5
volumes, analagous to vinum_mirror and vinum_stripe.
vinum_checkparity: Don't try to check the parity of a non-parity plex,
print a rude remark instead.
Approved-by: jkh
Suggested-by: Bernd Walter (ticso@cicely.de)
Add key pairs for 'mv' and 'move' (a synonym for 'mv'). Required for
the move command code submitted by Marius Bendiksen
<marius@marius.scancall.no>
make_devices: Don't create symlinks for drives if they are only
referenced. Previously, spurious symlinks appeared in the current
directory.
Problem-reported-by: Bernd Walter (ticso@cicely.de)
No longer create character devices, now that there is no difference.
Make the devices as character devices, not block devices.
on alpha.
Submitted-by: Bernd Walter <ticso@cicely.de>
Replace %q formats with %lld.
Desired-by: bde
Remove #ifdef RAID5
vinum_lsi: If a subdisk is in 'reviving' state, check the status of
the revive and report the status of the revive. In verbose mode,
display the pid of the reviver.
on alpha.
Submitted-by: Bernd Walter <ticso@cicely.de>
Add function vinum_mv, which moves subdisks to different drives. This
function just does the low-level configuration changes; the resultant
subdisk is stale if it previously had any contents, otherwise it is
empty (i.e. in need of initializing if it's RAID-5). We still need to
handle getting the contents moved over, but the current version will
suffice to migrate subdisks from a disk which has failed.
Submitted-by: Marius Bendiksen <marius@marius.scancall.no>
vinum_start: Get the revive block size right.
interface limits it to this anyway.
Change the name of the v flag variable from 'verbose' to 'vflag',
indicating the multiple use (verbose or verify).
Add -S flag to specify the size of some operations.
indicating the multiple use (verbose or verify).
vinum_ldi:
Show active requests for the drive if -v is specified.
White space cleanup.
vinum_lsi:
Show the progress of an init command if -v is specified.
vinum_info:
Print the number of active requests.
Print out loginfo_sdio and loginfo_sdiodone log entries.
indicating the multiple use (verbose or verify).
initsd: rewrite:
Initialization is now done in the kernel.
Verify (again!) if -v is specified.
Allow specification of a blocksize, the length to be transferred in
one transfer.
vinum_revive:
Allow specification of a blocksize, the length to be transferred in
one transfer.
vinum_lpi: Add information about progress of rebuildparity and
checkparity commands.
listconfig: Print object counts in a different format, don't refer to
the internal number of slots allocated:
Caused-confusion-to: Norbert Meissner <norbert.meissner@daimlerchrysler.com>
vinum_info: Change format of device numbers so that they fit in the
column (ignore high-order minor number bits, which aren't really of
much interest).
vinum_start: bzero the statinfo.dinfo struct. The lack of this was
causing sporadic failures of the start command.
Add body of vinum_checkparity command.
vinum_init(): Change name of variable plexindex to objindex, which
better describes its purpose.
initsd(): Add a second parameter to determine whether it should wait
for completion or not. This allows it to DTRT when called
with the -w flag either directly or via initplex().
Add 'setstate' command (function vinum_setstate ()) to implement the
VINUM_SETSTATE_FORCE ioctl for diddling individual object states.
This is a repair tool which can also be used for panicing the system.
Use with utmost care if at all.
Add unimplemented commands 'checkparity' and 'rebuildparity'. Watch
this space.