This could cause data corruption due to accessing wrong LUN in case of
retries on write errors. Failed writes were retried to read LUN.
MFC after: 3 days
Make CTL core and block backend set success status before initiating last
data move for read commands. Make CAM target and iSCSI frontends detect
such condition and send command status together with data. New I/O flag
allows to skip duplicate status sending on later fe_done() call.
For Fibre Channel this change saves one of three interrupts per read command,
increasing performance from 126K to 160K IOPS. For iSCSI this change saves
one of three PDUs per read command, increasing performance from 1M to 1.2M
IOPS.
MFC after: 1 month
Sponsored by: iXsystems, Inc.
Old allocator created significant lock congestion protecting its lists
of preallocated I/Os, while UMA provides much better SMP scalability.
The downside of UMA is lack of reliable preallocation, that could guarantee
successful allocation in non-sleepable environments. But careful code
review shown, that only CAM target frontend really has that requirement.
Fix that making that frontend preallocate and statically bind CTL I/O for
every ATIO/INOT it preallocates any way. That allows to avoid allocations
in hot I/O path. Other frontends either may sleep in allocation context
or can properly handle allocation errors.
On 40-core server with 6 ZVOL-backed LUNs and 7 iSCSI client connections
this change increases peak performance from ~700K to >1M IOPS! Yay! :)
MFC after: 1 month
Sponsored by: iXsystems, Inc.
This allows to avoid extra network traffic when copying files on NTFS iSCSI
disks within one storage host by drag'n'dropping them in Windows Explorer
of Windows 8/2012. It should also accelerate Hyper-V VM operations, etc.
MFC after: 2 weeks
Sponsored by: iXsystems, Inc.
After I gave each iSCSI target its own port, the old limit appeared to be
not so big. This change almost proportionally increases per-LUN memory
use, but it is still three times better then it was before r268807.
MFC after: 2 weeks
This allows to clone VMs and move them between LUNs inside one storage
host without generating extra network traffic to the initiator and back,
and without being limited by network bandwidth.
LUNs participating in copy operation should have UNIQUE NAA or EUI IDs set.
For LUNs without these IDs VMWare will use traditional copy operations.
Beware: the above LUN IDs explicitly set to values non-unique from the VM
cluster point of view may cause data corruption if wrong LUN is addressed!
MFC after: 2 weeks
Sponsored by: iXsystems, Inc.