This tells ppp to loopback packets addressed to
the ppp interface IP coming *from* the tun
device.
This means that you can ping the tun interface IP
from inside :-)
idependently time out any of the FSMs.
Split LCP logging into LCP, IPCP and CCP logging,
and make room in "struct fsm" for the log level
that the state machine should use.
"set stopped" directive. If the timeout occurs
it will cause a "Down" event, hanging up the line
if it's still up. This *isn't* part of the FSM
diagram, but I consider it ok as a "higher level
implementation specific timeout" as specified in
the rfc ;-}
Discussed briefly with: joerg
o Allow "set var" with no args to blank var (don't req "").
o Zero VarTerm ASAP if not in interactive mode.
o Never print anything to stdout in -direct mode.
o Count redial when failing to open modem.
o Increase device size to 40 characters (for host:port).
o Remove missed "if (fd == 0) fd = 1;".
o Don't give up on incoming non-terminal connections.
o Use syslog
o Remove references to stdout/stderr (incl perror())
o Introduce VarTerm - the interactive terminal or zero
o Allow "set timeout" to affect current session
o Change "set debug" to "set log"
o Allow "set log [+|-]flag"
o Make MSEXT and PASSWDAUTH stuff the default
o Move all #ifdef DEBUG stuff into the code - this
shouldn't be too much overhead. It's now controlled
with "set log +debug"
o Add "set log command, debug, tun, warn, error, alert"
o Remove cdefs.h, and assume an ansi compiler.
o Improve all diagnostic output
o Don't trap SIGSEGV
o SIGHUP now terminates again (log files are controlled
by syslog)
o Call CloseModem() when changing devices
o Fix parsing of third arg of "delete"
I think this fixes the "magic is same" problems that some
people have been experiencing.
The man page is being rewritten. It'll follow soon.
alias commands simply won't work. Only root may specify the
location of the alias lib (otherwise, it's hard-coded).
Make logprintf silently fail if LogOpen hasn't been called.
Suggested by: eivind
of reconnect & -background.
o Fix reconnect anomolies.
o Make reconnect apply to failed LQR hangups (& mention in man page).
o Make reconnect effective in -background mode.
o Listen on socket in -background mode.
o Try all phone numbers in -background mode.
o Insist on system arg in -background mode.
o Make a control-connection close command exit in -background mode.
o Output status message to stdout on exit of parent in -background mode.
o Don't notify parent of success too soon.
o Describe termination EX_* code.
o Miscelaneous diagnostic corrections.
o Remove redundant connect_time from modem.c.
o Don't repeatedly DownConnection().
the connection after an unexpected loss of carrier:
set reconnect timer ntries
The man page warns against using this command when your
timeout value is slightly more than the other sides :{}
Suggested by: burton@bsampley.vip.best.com (Burton Sampley)
This will make a number of things easier in the future, as well as (finally!)
avoiding the Id-smashing problem which has plagued developers for so long.
Boy, I'm glad we're not using sup anymore. This update would have been
insane otherwise.
on their own without even attempting to get concensus in the IETF, but
there are also lots of Win95/NT boxes out there.
CLoses PR#1494
Submitted-By: Peter Childs <pjchilds@imforei.apana.org.au>
2) Improve on-line help subsystem
3) Make 'term' mode works even carrier dropped (old code
close line forever here)
4) Make 'term' mode 8bit clean.
5) Improve manual page
6) #ifdef DEBUG diagnostic about missing optional files.
7) Don't put interactive dialing info to logfile
A settable redial timer helps to avoid the problem where both ends
of a link want to dial at the same time and the line winds up busy
for both ends. The process id is logged in /var/run/PPP.system where
system is the name of the called system. When both ends of a link
are running in demand dial mode, you need an easy way to get the pid
of the ppp on the called end so it can be killed and re-started with
-direct or pppd started to handle the incoming ppp session.
2. Add secret description for "set timeout" to man.
Reviewed by: Atsushi Murai <amurai@spec.co.jp>
Submitted by: John Capo <jc@irbs.com>
2.Implment Redail function as working correctly.
3.Clean up a code as I notice.
4.Now, RTT getting close to 50ms with ISDN/TA 38400bps !!
Reviewed by: amurai@spec.co.jp
Submitted by: amurai@spec.co.jp
o Supporting SYNC SIO device (But need a device driver)
- add "set speed sync"
o Fixing bug for Predictor-1 function.
o Add new parameter that re-sent interval for set timeout commands.
o Improving RTT (Round Trip Time) and reducing processor time.
- Previous Timer service was using polling, and now using
SIGALRM ;-)
- A 0.94beta2 will not work correctly....
-- Follows are additinal feature not including 0.94beta2
o Support Proxy ARP
- add "enable/disable proxy" commands
o Marging common routine in CHAP/PAP.
o Enhancing LCP/IPCP log information.
o Support local Authfication connection on port 300x and tty.
- You can set up pair of your "hostname -s" and
password in ppp.secret. if either ppp.secret file nor
your hostname line don't exist, It will notify a message
and working as same as previous version.(Backword compatibility)
- If you did set up them, It's allow connection but nothing to do
except help and passwd command.
- add "passwd yourpasswd" commands
o Support afilter - keep Alive filter that a packet can send/receiving
according to ifilter/ofilter but doesn't count it as preventing idle
timer expires.
- Same syntax of other filters.
o Fixing bugs reported by current user for previous one. Thanks !!
Reviewed by: Atsushi Murai (amurai@spec.co.jp)