o Honor NE2000DVF_{AX88190,DL10019} flags by setting the ED_FLAGS_xxxx
flag.
o Mark linksys combo_ecard as ax88190
o Set the type_str to AX88190 for the ax88190 cards.
This fixes ax88190 based cards, for the most part, but doesn't seem to fix
the mii based dl10019 cards (aka linksys cards).
card is ejected while we're in this routine.
yamamoto-san's original patch had a small race window for AX88190
chips, which I corrected by limiting the number of iterations we'd try
to reset the bits to be about 15ms rather than forever. This seems to
work for me, but I don't have a large collections of cards based on
this chipset.
Submitted by: YAMAMOTO Shigeru
built without support for miibus PHYs. Most ed cards don't need
miibus support, so it's useful to be able to avoid the bloat of
all the mii devices for small fixed-purpose kernels.
storing a flag in the global variable 'linksys' during the probe
routine and reading it during the attach routine. We now have the
ED_VENDOR_LINKSYS vendor code stored in sc->vendor, so check that
instead.
not from the probe routine. This was an oversight when I originally
ported the miibus support to -current, though it was mostly harmless.
We now set the vendor code to the new value ED_VENDOR_LINKSYS in
ed_pccard_Linksys() at probe time. Then ed_pccard_attach() checks
the vendor code, and sets up the miibus if appropriate.
Reviewed by: imp
bolted to a ne-2000 chip. This is necessary for the NetGear FA-410TX
and other cards.
This also requires you add mii to your kernel if you have an ed driver
configured.
This code will result in a couple of timeout messages for ed on the
impacted cards. Additional work will be needed, but this does work
right now, and many people need these cards.
Submitted by: Ian Dowse <iedowse@maths.tcd.ie>
* a ">" is really ">=" ;
* do not try to fetch zero-sized blocks from the card;
* make sure that bpf gets the packets it wants even with
bridging active;
o Move the ax88190 code to its own function.
o Move all device_method_t, driver_t and DRIVER_MODULE definitions to the
end of files.
o Wrap a few lines > 80 characters.
o Use the same devclass for all ed drivers. This allows machines with
multiple types of cards to have their cards numbered correctly. Before,
you could wind up with two ed0's.
o Protect if_edvar.h from multiple includes because I was there.
require the addition of flag 0x80000 to their config line in
pccard.conf(5). This flag is not optional. These Linksys cards will
not be recognized without it.
Reviewed by: imp, iwasaki
using a cardbus based system with pccbb providing the pcic interface).
Something isn't quite right.. when the driver allocates and activates
its resources, the IO space that was requested reads as all zeros (versus
the original 0xff's as it normally is when there is no device responding).
Also, deactivate the resources before releasing them. OLDCARD doesn't
seem to care but NEWCARD/CARDBUS get rather unhappy if you release
a resource that hasn't been deactivated yet.
Make pcic_p.c only compile with oldcard kernels.
ether_ifdetach().
The former consolidates the operations of if_attach(), ng_ether_attach(),
and bpfattach(). The latter consolidates the corresponding detach operations.
Reviewed by: julian, freebsd-net