change channel interface - kobj implementation coming soonish
make pcm_makelinks not panic if modular
add pcm_unregister()
these changes support newpcm kld unloading, but this is only implemented
by ds1.c
datagram embedded into ICMP error message, not with protocol
field of ICMP message itself (which is always IPPROTO_ICMP).
Pointed by: Erik Salander <erik@whistle.com>
rather than implementing its own {uid,gid,other} checks against vnode
mode. Similar change to linprocfs currently under review.
Obtained from: TrustedBSD Project
fields between host and network byte order. The details:
o icmp_error() now does not add IP header length. This fixes the problem
when icmp_error() is called from ip_forward(). In this case the ip_len
of the original IP datagram returned with ICMP error was wrong.
o icmp_error() expects all three fields, ip_len, ip_id and ip_off in host
byte order, so DTRT and convert these fields back to network byte order
before sending a message. This fixes the problem described in PR 16240
and PR 20877 (ip_id field was returned in host byte order).
o ip_ttl decrement operation in ip_forward() was moved down to make sure
that it does not corrupt the copy of original IP datagram passed later
to icmp_error().
o A copy of original IP datagram in ip_forward() was made a read-write,
independent copy. This fixes the problem I first reported to Garrett
Wollman and Bill Fenner and later put in audit trail of PR 16240:
ip_output() (not always) converts fields of original datagram to network
byte order, but because copy (mcopy) and its original (m) most likely
share the same mbuf cluster, ip_output()'s manipulations on original
also corrupted the copy.
o ip_output() now expects all three fields, ip_len, ip_off and (what is
significant) ip_id in host byte order. It was a headache for years that
ip_id was handled differently. The only compatibility issue here is the
raw IP socket interface with IP_HDRINCL socket option set and a non-zero
ip_id field, but ip.4 manual page was unclear on whether in this case
ip_id field should be in host or network byte order.
not alias `ip_src' unless it comes from the host an original
datagram that triggered this error message was destined for.
PR: 20712
Reviewed by: brian, Charles Mott <cmott@scientech.com>
This provides support for the Adaptec SCSI RAID controller family,
as well as the DPT SmartRAID V and VI families.
The driver will be maintained by Mark and Adaptec, and any changes
should be referred to the MAINTAINER.
cached when not in use. This changes the FreeBSD default from 30 minutes
to 5 minutes. JKH was the one that added the override to amd_flags, but
there was no reason given other to serve as an example of what could be
done.
pcib_set_bus() cannot be used on the new child because it is
meant to be used on the *pci* device (it looks at the parent internally)
not the pcib being added. Bite the bullet and use ivars for the bus
number to avoid any doubts about whether the softc is consistant between
probe and attach. This should not break the Alpha code.
foo_pcib_[read|write]_config() functions rather than relying on
a break or return being in the CFG macro.
This fixes a panic later in the boot process on a UP1000. From
inspection, it looks like this fixes a similar problem in the tsunami code.
Approved by: dfr
kern.ps_showallprocs. Apparently got lost in the merge process from
the capability patches. Now fixed.
Submitted by: jdp
Obtained from: TrustedBSD Project