+ Use rc.subr(8) features properly.
+ Do the whole job of obliterating /tmp contents in find(1).
+ Leave lost+found and quota.{user,group} in /tmp only if root-owned.
+ Make the overall structure clearer by first removing the X dirs
(perhaps along with the rest of /tmp) and then re-creating them.
+ Use "find -exec rm -rf {} +" for efficiency: each rm instance gets
a chance to kill as much files in /tmp as ARG_MAX permits.
PR: bin/104044
Submitted by: Andrey Simonenko <see PR for email>
Hacked by: yar
MFC after: 1 month
chance to actually terminate the audit service and exit. Otherwise, on
an rc.d/auditd restart, the new audit daemon instance may try to start
auditing while the previous session is still running. Likewise, this
ensures a chance for auditd to terminate the audit trail at system
shutdown.
Perhaps more ideally, the script would wait synchronously for auditd to
exit rather than for an arbitrary but short period of time.
MFC after: 3 days
Obtained from: TrustedBSD Project
certain conditions. I haven't been able to find a better solution yet:
- Set a two read-only variables (${prefix} and ${etcdir}). This is
especially useful when using /etc/rc.d scripts with third-party
software installed from ports.
- Fix rc.d/sshd to work with openssh from ports using ${etcdir}
instead of hardcoded /etc.
- Reflect prefix/etcdir changes in rc.subr.8.
src/etc/rc.d/sshd: rev 1.9 -> 1.10
src/etc/rc.subr: rev 1.51 -> 1.52
src/share/man/man8/rc.subr.8: rev 1.11 -> 1.12
Approved by: cperciva (mentor)
despite the interface link status.
Add dhclient_flags_iface and background_dhclient_iface rc.conf options.
(where iface is a specific interface). These can be used to give
interface specific flags to dhclient.
Reviewed by: brooks@
and replace it with a new ntpdate_config variable.
- Document it in defaults/rc.conf and rc.conf.5.
- Document ntpdate_hosts in defaults/rc.conf.
Requested by: Chris Timmons <cwt@networks.cwu.edu>
Approved by: cperciva (mentor, implicit)
MFC after: 1 week
not be mounted unless the -l flag was specified.
Add an rc script, mountlate, which basically runs 'mount -a -l'. It runs
after DAEMON but before LOGIN.
This is useful for things like loopback mounts, because mountcritremote
runs before mountd / nfsd (since /usr might be a remote file system), so
an attempt to mount a loopback network file system in mountcritremote will
fail.
Also add a progress message to mountcritlocal, for the sake of symmetry
with similar messages in mountcritremote and mountlate.
Reviewed by: freebsd-rc
MFC after: 3 weeks
expect to see quite a few files appearing in libdata/ldconfig directories.
This change avoids the screen to be filled with the names of those ldconfig
files and replace them by the actual non-default directories they contain.
Most of them will be ${PREFIX}/lib so, 'sort -u' will help reducing the
output.
Approved by: cperciva (implicit)
MFC after: 1 week
automaticly add it to an Ethernet bridge. This is intended for applications
such as qemu, vmware, openvpn, ... which open tap interfaces and need them
bridged with the hosts network adapter, the user can set up a glob for
interfaces to be automatically added (eg tap*).
notification so all interfaces including pseudo are reported. When netif
creates the clones at startup devctl_disable has not been turned off yet so the
interfaces will not be initialised twice, enforce this by adding an explicit
order between rc.d/netif and rc.d/devd.
This change allows actions to taken in userland when an interface is cloned
and the pseudo interface will be automatically configured if a ifconfig_<int>=""
line exists in rc.conf.
Reviewed by: brooks
No objections on: net
1,2 and so on.
It specifies the command to be run as Nth after jail startup.
sh(1)-fu by: Dario Freni
PR: conf/97697
MFC after: 2 weeks
Reviewed by: ru@ (man page)
scripts. These scripts handle vnode backed md(4) devices.
Old ramdisk{,-own} scripts will stay a bit in CVS to allow some time for
migration since variable names have changed (ramdisk_* -> mdconfig_*).
Two new variables have been introduced to be able to populate the md(4)
device once it has been mounted (mdconfig_*_files and mdconfig_*_cmd).
Use should be as easy as:
mdconfig_md0="-t malloc -s 10m"
mdconfig_md1="-t vnode -f /var/foo.img"
See rc.conf(5) for more information and description of the additional
variables.
Approved by: cperciva
issue where some global jail_* variables were overriden in the script. [1]
- Change "jid" to "jname" in rc.conf(5), since it's more a jail name than a
jail id. [1]
- Update examples and comments in defaults/rc.conf to advertise new
variables and the fact that some of the jail-specific variables may be made
jail-global. [2]
Reported by: pjd [1], clsung [2]
Approved by: cperciva
X-MFC after: i got sufficient testing from people using rc.d/jail
boot. Autogeneration of nsswitch.conf doesn't makes sense in 7.0
since it's not permitted to upgrade from a pre-nss release without
passing through an intermediate release.
Suggested by: brooks