The "domain-search" option (option 119) allows a DHCP server to publish
a list of implicit domain suffixes used during name lookup. This option
is described in RFC 3397.
For instance, if the domain-search option says:
".example.org .example.com"
and one wants to resolve "foobar", the resolver will try:
1. "foobar.example.org"
2. "foobar.example.com"
The file /etc/resolv.conf is updated with a "search" directive if the
DHCP server provides "domain-search".
A regression test suite is included in this patch under
tools/regression/sbin/dhclient.
PR: bin/151940
Sponsored by Yakaz (http://www.yakaz.com)
Firmware can be reprogrammed on devices from Hitachi, HP, IBM, Plextor,
Quantum, and Seagate. At least one device from each manufacturer has
been tested with some version of this code, and it has been used to
update thousands of drives so far.
The man page suggests having a backup of the drive's data, and the
operation must be confirmed, either interactively or on the command
line. (This is the same as the confirmation on the format command.)
This work is largely derived from fwprog.c by Andre Albsmeier.
Submitted by: Nima Misaghian
Sponsored by: Sandvine Incorporated
MFC after: 3 months
existing sections to refer to the new one. Rearrange partitioning scheme
list so MBR and EBR types are together. Also add several corrections for
grammar, clarity, and consistency.
Approved by: gjb (mentor)
MFC after: 1 week
- Improved locking and destruction process to fix crashes.
- Improved "automatic" configuration method to make it consistent and safe
by reading metadata back from all specified paths after writing to one.
- Added provider size check to reduce chance of ordering conflict with
other GEOM classes.
- Added "manual" configuration method without using on-disk metadata.
- Added "add" and "remove" commands to allow manage paths manually.
- Failed paths are no longer dropped from geom, but only marked as FAIL
and excluded from I/O operations.
- Automatically restore failed paths when all others paths are marked
as failed, for example, because of device-caused (not transport) errors.
- Added "fail" and "restore" commands to manually control FAIL flag.
- geom is now destroyed on last path disconnection.
- Added optional Active/Active mode support. Unlike Active/Passive
mode, load evenly distributed between all working paths. If supported by
the device, it allows to significantly improve performance, utilizing
bandwidth of all paths. It is controlled by -A option during creation.
Disabled by default now.
- Improved `status` and `list` commands output.
Sponsored by: iXsystems, inc.
MFC after: 1 month
change the on-disk format in an incompatible way. Without this change,
msdosfs created on FreeBSD/arm would not be mountable.
PR: bin/162486
Submitted by: Ian Lepore <freebsd damnhippie dyndns org>
Reported by: Mattia Rossi <mrossi at swin.edu.au>
MFC after: 3 days
This allows a hostap to specify to a set of stations that they
should not transmit for a certain period of time after each
beacon interval has expired. This is used when searching for
radar pulses or general interference.
Submitted by: Himali Patel <himali.patel@sibridgetech.com>
Sponsored by: Sibridge Technologies
Remove obsolete code which uses DIOCSMBR ioctl.
When writing MBR first check that GEOM_MBR is available, if it is not
available, then try write MBR directly to provider. If both are failed,
then recommend to use gpart(8).
MFC after: 2 week
fields, but user could specify some of those fields when edits disklabel
with `bsdlabel -e`. But without -A flag these fields might be
overwritten with default values from the virgin disklabel.
So, don't overwrite such fields if they are not zero. Also add checks
to prevent creating disklabel with less than DEFPARTITIONS and more
than MAXPARTITIONS partitions.
PR: bin/162332
Tested by: Eugene Grosbein
MFC after: 1 week
These tools declare global variables without using the static keyword,
even though their use is limited to a single C-file, or without placing
an extern declaration of them in the proper header file.
write. This way on first connection we will synchronize only the extents that
were modified during the lifetime of primary node, not entire GEOM provider.
MFC after: 3 days
- add support for volumes above 2TiB with Promise metadata format;
- enforse and document other limitations:
- Intel and Promise metadata formats do not support disks above 2TiB;
- NVIDIA metadata format does not support volumes above 2TiB.
Sponsored by: iXsystems, Inc.
MFC after: 2 weeks
the logic (true/false) of the matching.
- Add "!usbus[0-9]+" to IFNET ATTACH notification handler in the default
devd.conf to prevent rc.d/netif from running when usbus[0-9]+ is attached.
Reviewed by: imp