event of a broken or busy fan due to returning incorrect error codes from
the FCU sysctl handler.
Reported by: Path Mather <paul at gromit dot dlib dot vt dot edu>1
Approved by: re (kib)
smell that caused me to turn this up was due to a failed fan burning, not
a CPU (plus a healthy dose of paranoia).
Submitted by: Paul Mather <paul at gromit dot dlib dot vt dot edu>
the pwm values. We can now set the fan's speed of a PWM controlled fan
with % numbers between 30 and 100 % instead of trying to model a
% number based on rpm.
The fcu chip offers both, the dutycycle and the rpm value of the PWM
controlled fans. I added the rpm value to the list of information
available via sysctl(8).
Tested by: Paul Mather <paul at gromit dlib vt edu>
Approved by: nwhitehorn (mentor)
PowerMac7,2.
- The fcu driver lets us read and write the fan RPMs for all fans in the
PowerMac7,2. This driver is PowerMac specific.
- The ds1775 is a driver to read the temperature for the drive bay sensor.
- The max6690 is another driver to read temperatures. Here it is used to
read the inlet, the backside and the U3 heatsink temperature.
An additional driver, the ad7417, will follow later.
Thanks to nwhitehorn for guiding me through this driver development.
Approved by: nwhitehorn (mentor)