For Lenovo laptops with buggy bios (x220, t420, t520):
Write the 0xee entry into the second slot in the pmbr instead of the first
For some Dell and HP models:
The BIOS gives a warning message when booting in legacy mode from a GPT partitioned disk where the 0xee partition in the pmbr is not flagged active
For models known to have this problem, mark the pmbr active during installation
Use smbios data to identify machines known to be affected by any of the above, and offer the user the option to apply the workaround
In bsdinstall's ufs auto mode (autopart partition wizard):
Allow users to select which type of partition table to use
Keep current defaults: MBR for BIOS, GPT for UEFI
This allows users to choose GPT for legacy boot if they wish
PR: 184910
PR: 194359
Reviewed by: Michael Dexter
Approved by: marcel
MFC after: 3 days
X-MFC-With: r285594
Relnotes: yes
Sponsored by: ScaleEngine Inc.
Differential Revision: https://reviews.freebsd.org/D3091
A variable was misspelled resulting in chmod executing on the installer instead of on the target chroot
PR: 191402
Submitted by: Martin Simmons <martin@lispworks.com>
Approved by: brueffer
MFC after: 3 days
Sponsored by: ScaleEngine Inc.
Differential Revision: https://reviews.freebsd.org/D3061
Off by default, build behaves normally.
WITH_META_MODE we get auto objdir creation, the ability to
start build from anywhere in the tree.
Still need to add real targets under targets/ to build packages.
Differential Revision: D2796
Reviewed by: brooks imp
A new loader.conf(5) option of geom_eli_passphrase_prompt="YES" will now
allow you to enter your geli(8) root-mount credentials prior to invoking
the kernel.
See check-password.4th(8) for details.
Differential Revision: https://reviews.freebsd.org/D2105
Reviewed by: imp, kmoore
Discussed on: -current
MFC after: 3 days
X-MFC-to: stable/10
Relnotes: yes
Summary:
Add "GELI Passphrase:" prompt to boot loader.
A new loader.conf(5) option of geom_eli_passphrase_prompt="YES" will now
allow you to enter your geli(8) root-mount credentials prior to invoking
the kernel.
See check-password.4th(8) for details.
Differential Revision: https://reviews.freebsd.org/D2105
Reviewed by: (your name[s] here)
MFC after: 3 days
X-MFC-to: stable/10
Relnotes: yes
Test Plan:
Drop a head copy of check-password.4th into /boot and then apply the patch
(only the patch to /boot/check-password.4th is required; no other changes are
required but you do have to have a HEAD copy of check-password.4th to
apply the patch).
NB: The rest of your /boot files can be up to 2 years old but no older.
NB: The test won't work unless your kernel has the following change
https://svnweb.freebsd.org/base?view=revision&revision=273489
Now, put into /boot/loader.conf:
geom_eli_passphrase_prompt="YES"
and reboot.
You should be prompted for a GELI passphrase before the menu (if enabled),
just after loading loader.conf(5).
NB: It doesn't matter if you're using GELI or not. However if you are using
GELI and a sufficiently new enough release (has SVN r273489) and you entered
the proper passphrase to mount your GELI encrypted root device(s), you should
notice that the boot process did not stop (you went from loader all the way to login).
Reviewers: cperciva, allanjude, scottl, kmoore
Subscribers: jkh, imp
Differential Revision: https://reviews.freebsd.org/D2105
bsdconfig's f_package_add doesn't seem to support using the pkg repo from /etc/pkg/FreeBSD.conf, it also tries to run the commands on the installer image, not in the destination chroot
Instead, manually bootstrap pkg in the chroot, and then install the requested packages (in the chroot)
Doesn't use pkg -c, because pkg is not installed on the installer image
PR: 196250
Differential Revision: https://reviews.freebsd.org/D2026
Approved by: bapt
Sponsored by: ScaleEngine Inc.
assume that GPT means UEFI boot, resulting in the installation of
uninstallable systems. This needs a little more work before MFC, in
particular based on disk size (> 2 TB + BIOS + MBR is not workable). That
will come soon.
Previously we used gnop(8) to fake 4K sector size disks but ZFS now has a
sysctl to control this when creating new top level vdev's so use that
instead.
Differential Revision: D566
MFC after: 1 month
Sponsored by: Multiplay
new dpv(3) wrapper to dialog(3) dialog_gauge(). The dpv(3) library provides
a more flexible and refined interface similar to dialog_mixedgauge() however
is implemented atop the more generalized dialog_gauge() for portability.
Noticeable improvements in bsdinstall's distextract will be a status line
showing data rate information (with support for localeconv(3) to format
numbers according to $LANG or $LC_ALL conversion information), i18n support,
improved auto-sizing of gauge widget, a ``wheel barrow'' to keep the user
informed that things are moving (even if status/progress has not changed),
improved color support (mini-progress bars use the same color, if enabled,
as the main gauge bar), and several other improvements (some not visible).
dpv stands for "dialog progress view" (dpv was introduced in SVN r274116).
Differential Revision: https://reviews.freebsd.org/D714
Discussed on: -current
Reviewed by: julian
MFC after: 3 days
X-MFC-to: stable/10
Relnotes: Improved installer feedback from bsdinstall distextract
less obsolete information. Also move the entropy command down the list --
the list is ordered by likelihood of use rather than alphabetically.
MFC after: 1 week
while here:
+ Fix an issue when extracting small archives where dialog_mixedgauge was
not rendering; leaving the user wondering if anything happened.
+ Add #ifdef's to assuage compilation against older libarchive
NB: Minimize diff between branches; make merging easier.
+ Add missing calls to end_dialog(3)
+ Change string processing from strtok(3) to strcspn(3) (O(1) optimization)
+ Use EXIT_SUCCESS and EXIT_FAILURE instead of 0/1
+ Optimize getenv(3) use, using stored results instead of calling repeatedly
NB: Fixes copy/paste error wherein we display getenv(BSDINSTALL_DISTDIR) in
an error msgbox when chdir(2) to getenv(BSDINSTALL_CHROOT) fails
(wrong variable displayed in msgbox).
+ Use strtol(3) instead of [deprecated] atoi(3)
+ Add additional error checking (e.g., check return of archive_read_new(3))
+ Assign DECONST strings to static variables
+ Fix typo in distextract.c error message (s/Could could/Could not/)
+ Add comments and make a minor whitespace adjustment
Reviewed by: nwhitehorn, julian
Use adequately sized buffer for error(s) (512 -> PATH_MAX + 512).
Fix the following style(9) nits while here:
- distfetch.c uses PATH_MAX while distextract.c uses MAXPATHLEN;
standardize on one (PATH_MAX)
- Move $FreeBSD$ from comment to __FBSDID()
- Sort included headers (alphabetically, sys/* at top)
- Add missing header includes (e.g., <stdlib.h> for getenv(3),
calloc(3)/malloc(3)/free(3), and atoi(3); <string.h> for strdup(3),
strrchr(3), strsep(3), and strcmp(3); <ctype.h> for isspace(3); and
<unistd.h> for chdir(2), etc.)
- Remove rogue newline at end of distfetch.c
- Don't declare variables in if-, while-, or other statement
NB: To prevent masking of prior declarations atop function
- Perform stack alignment for variable declarations
- Add missing function prototype for count_files() in distextract.c
- Break out single-line multivariable-declarations
NB: Aligning similarly-named variables with one-char difference(s)
NB: Minimizes diffs and makes future diffs more clear
- Use err(3) family of functions (requires s/int err;/int retval;/g)
Reviewed by: nwhitehorn, julian
ZFS property canmount=off so that /var/db/pkg and other such directories
are part of the / dataset, and only /var/mail, /var/log, and /var/crash
are excluded from the ZFS boot environment (beadm).
PR: 193971
Approved by: jmg
MFC after: ASAP
Relnotes: yes
Sponsored by: ScaleEngine Inc.
reality. In particular, draw a connection between the auto ZFS script and
the auto UFS one, since they fulfill similar functions. I'm not sure the
auto ZFS code is actually experimental anymore, so it might be worth
changing that label still.
partitions of types other than "freebsd-boot" (in particular, "efi").
This allows the removal of some nasty hacks for supporting PowerPC systems,
in particular aliasing freebsd-boot to apple-boot on APM and an IBM-specific
code on MBR.
This changes the installer to use the correct names, which also breaks a
degeneracy in the meaning of "freebsd-boot" that allows the addition
of support for some newer IBM systems that can boot from GPT in addition to
MBR. Since I have no idea how to detect which those systems are, leave
the default on IBM PPC systems as MBR for now.
an embedded newline appearing within the options string surrounded by
double-quotes. Rework the logic that goes into setting dataset options on
the root pool dataset while we're here -- added two new variables (which
can be altered via scripting) ZFSBOOT_POOL_CREATE_OPTIONS and also
ZFSBOOT_BOOT_POOL_CREATE_OPTIONS for setting pool/dataset attributes at
the time of pool creation. The former is for setting options on the root
pool (zroot) and the latter is for setting options on the optional separate
boot pool (bootpool) implicitly enabled when using either GELI or MBR. The
default value for the root pool variable (ZFSBOOT_POOL_CREATE_OPTIONS) is
"-O compress=lz4 -O atime=off" and the default value for separate boot pool
variable (ZFSBOOT_BOOT_POOL_CREATE_OPTIONS) is NULL (no additional options
for the separate boot pool dataset).
Reviewed by: allanjude
MFC after: 7 days
X-MFC-with: r266107-266109
It starts off being used to track the grammar for the number of disks
(singular vs plural) and then it is reused as the list of available disks.
Replace the variable with disks_grammar and move 'disk' and 'disks' to
msg_ vars so they can be translated in the future.
Submitted by: Allan Jude <freebsd@allanjude.com>
Reviewed by: roberto
MFC after: 2 weeks
Sponsored by: ScaleEngine Inc.
Set compress=lz4 for the entire pool, removing it from the individual
datasets
Remove exec=no from /usr/src, breaks the test suite.
Submitted by: Allan Jude <freebsd@allanjude.com>
Reviewed by: roberto
MFC after: 2 weeks
Sponsored by: ScaleEngine Inc.
encryption for swap, and optional gmirror for swap (which can be combined)
Submitted by: Allan Jude <freebsd@allanjude.com>
Requested By: roberto
Sponsored By: ScaleEngine Inc.
MFC after: 2 weeks
a sysctl to determine what firmware is in use. This sysctl does not exist
yet, so the following blocks are in front of the wheels:
- I've provisionally called this "hw.platform" after the equivalent thing
on PPC
- The logic to check the sysctl is short-circuited to always choose BIOS.
There's a comment in the top of the file about how to turn this off.
If IA64 acquired a boot1.efifat-like thing (probably with very few
modifications), the same code could be adapted there.
GEOM support (thereby adding GEOM support to the disk selection
menu of bsdinstall(8)'s `zfsboot' module updated herein).
MFC after: 1 week
X-MFC-with: 264840
that the slightly older dialog(1) requires --separate-output when using the
--checklist widget to force response to produce unquoted values (whereas in
stable/10 --checklist widget without --separate-output will only quote the
checklist labels in the response if the label is multi-word (contains any
whitespace).
Since these enhancements (see revisions 263956 and 264437) were developed
originally on 10, the --separate-output option was omitted. When merged to
stable/9, we (Allan Jude) and I found during testing that the "always-
quoting" of the response was causing things like struct interpolation to
fail (`f_struct device_$dev' would produce `f_struct device_\"da0\"' for
example -- literal quotes inherited from dialog(1) --checklist response).
To see the behavior, execute the following on stable/9 versus stable/10:
dialog --checklist disks: 0 0 0 da0 "" off da1 "" off
Check both items and hit enter. On stable/10, the response is:
da0 da1
On stable/9 the response is:
"da0" "da1"
If you use the --separate-output option, the response is the same for both:
da0
da1
So applying --separate-output on every platform until either one of two
things occurs 1) dialog(1,3) gets synchronized between stable/9, higher or
2) we drop support for stable/9.
MFC after: 3 days
Reviewed by: Allan Jude
and finish the job. ncurses is now the only Makefile in the tree that
uses it since it wasn't a simple mechanical change, and will be
addressed in a future commit.
NB: If the zfsboot variables ($ZFSBOOT_*) are set, a script is
assumed to want zfsboot module instead of scriptedpart module.
Submitted by: Loïc Brarda <loic.brarda@cern.ch>
Reviewed by: nwhitehorn@
MFC after: 3 days
commit c1acf022c5
Author: Brooks Davis <brooks@one-eyed-alien.net>
Date: Fri Jan 17 21:46:44 2014 +0000
Add an option WITHOUT_NCURSESW to suppress building and linking to
libncursesw. While wide character support it useful we'd like to
only need one ncurses library on embedded systems.
MFC after: 4 weeks
Sponsored by: DARPA, AFRL
in the one-line comment associated with the dumpdev setting was not present
for the case where the user deselects the dumpdev service (restoring pre-
r256348 behaviour.
MFC After: 3 days
only allows basic username/password config, and does not provide the
ability to set any of the other WPA options. Regardless, this is
generally sufficient to associate.
Perhaps in the future this could allow full configuring (e.g. being able
to set "anonymous identity", and perhaps some of the more obscure WPA
options), though perhaps that will better belong in bsdconfig when that
grows wlan config ability.
MFC after: 1 week
location of /etc/rc.local on the install media is more appropriate as it
knows serial vs. non-serial and can also do the change earlier (so that
even the initial Install dialog can benefit from the change).
MFC after: 3 days
installation to 3-4+ (depending on vdev type) vdevs would result in odd
error messages where the zpool `create' command appeared to repeat itself
(an artifact of printf when you supply too many arguments -- caused by
neglecting to properly quote the multi-word expansion of $*vdevs when
creating the pool(s)). Example error below (taken from bsdinstall_log):
DEBUG: zfs_create_boot: Creating root pool...
DEBUG: zfs_create_boot: zpool create -o altroot=/mnt -m none -f "zroot" \
ada0p3.nop ada1p3.nopzpool create ada2p3.nop "ada3p3.nop"
DEBUG: zfs_create_boot: retval=1 <output below>
cannot open 'ada1p3.nopzpool': no such GEOM provider
DEBUG: Running installation step: hostname
rm: /tmp/bsdinstall_etc/fstab: No such file or directory
The two lines are unrelated, and the rm is spurious. Let's add `-f' to
that rm(1) so it doesn't confuse us when debugging an install.
MFC after: 3 days
should not have used DIALOG_CANCEL because dialog.subr wasn't included to
define it. The effect of the error was that you could not cancel the
partition dialog. Discovered by checking bsdinstall_log for something else.
MFC after: 3 days
required in such a case). But don't prevent the user from pointing the
gun at his/her foot -- you can disable 4k alignment after enabling geli).
MFC after: 3 days
and subsequent headaches caused by multiple pools with the same name.
Specifically, blast away any labels on the designated swap partition.
Problem was when you install to a given layout *with* swap and then turn
around and re-install the same layout *without* swap (we weren't doing a
labelclear for the swap device, so would end up with an "UNAVAIL" status
zroot pool that may only exist in the pool cache).
MFC after: 3 days
+ For GPT, always provision zfs# partition after swap [for resizability]
+ For MBR, always use a boot pool to relialy place root vdevs at EOD
NB: Fixes edge-cases where MBR combination failed boot (e.g. swap-less)
+ Generalize boot pool logic so it can be used for any scheme (namely MBR)
+ Update existing comments and some whitespace fixes
+ Change some variable names to make reading/debugging the code easier
in zfs_create_boot() (namely prepend zroot_ or bootpool_ to property)
+ Because zroot vdevs are at EOD, no longer need to calculate partsize
(vdev consumes remaining space after allocating swap)
+ Optimize processing of disks -- no reason to loop over the disks 3-4
separate times when we can logically use a single loop to do everything
Discussed on: -stable
MFC after: 3 days
+ De-obfuscate debugging to show actual values
+ Change graid(8) syntax; s/destroy/delete/ [destroy is not invalid syntax]
+ Log commands that were previously quiet
+ Added some new comemnts and updated some existing ones
+ Add missing local for `disk' used in zfs_create_boot()
+ Use $disks instead of multiply-expanding $* in zfs_create_boot()
+ Pedantically unset variable holding geli(8) passphrase after use
+ Pedantically add double-quotes around zpool names and zfs datasets
+ Fix quotation expansion for zpool_cache entries of loader.conf(5)
+ Some limited whitespace changes
MFC after: 3 days
https://communities.vmware.com/thread/107230https://communities.vmware.com/docs/DOC-11677
Basically, ignore the ``function 62'' and ``function 63'' interpretations
of the left/right command key when we're in the lengthiest portion of the
installation (initiated by the `auto' module).
The net effect is that you can now (once you've started the installer from
the media) escape the VM without prematurely terminating the current action
due to spurious escape sequence.
MFC after: 3 days
===
DEBUG: Running installation step: services
local: Not in a function
/usr/libexec/bsdinstall/services: cannot create : Read-only file system
/usr/libexec/bsdinstall/services: /tmp/bsdinstall/etc/rc.conf.services: \
Permission denied
===
The `local: Not in a function' is obvious, and was introduced by myself in
SVN revision 256348.
The latter two are caused by the attempt to use "\" to continue the line
after using the ">>" redirect. This appears to attempt to write a file with
the name " " in the current directory and subsequently attempts to execute
the file that was originally intended for writing (which is not executable;
hence the `Permission denied'). That was introduced in SVN r228192 about
2 years ago, apparently unnoticed until I started going over the debug
outputs very carefully.
MFC after: 3 days
after attempting to install to encrypted ZFS root (caused by a typo in a
variable name -- ZFSBOOT_BOOT_FSNAME -> ZFSBOOT_BOOTFS_NAME).
MFC after: 3 days
The effects of this patch would only be noticeable if you were purposefully
setting a bad value and trying to see what happens; and leaving the disks
intact if a bad value has been set seems fair.
+ Add a `-D FILE" command-line option for overriding the path to the
bsdinstall log file (BSDINSTALL_LOG env var).
+ Document new `-D FILE' in the man page for bsdinstall.
+ If FILE in `-D FILE' begins with a +, debug output goes to stdout
(interleaved between dialog(1) invocations/output) as well as to FILE
(minus the leading + of course).
+ If BSDINSTALL_LOG cannot be written, then debugging is disabled (except in
the case of a leading + in the pathname, wherein debug will still be
printed to stdout).
+ Update source code formatting style.
+ Fix a dangling participle ("Begun ..." -> "Began ...")
+ Rewrite the docsinstall script (was necessary to abate direct dependency
on BSDINSTALL_LOG (instead, use fault-tolerant bsdconfig framework which
displays appropriate errors for package management).
NB: docsinstall is still using pkg(8) after this change.
+ Add additional debug output for dhclient/rtsol/wpa_cliscan
+ Display script errors in a textbox rather than just on stdout
+ Update many coments.
+ Add new f_show_err() API call (like f_show_msg but changes the dialog
title to "Error")(see bsdconfig's `common.subr').
+ Add new f_eval_catch() API call for executing a command via eval but not
before logging the command to debug. Several example cases documented in
API header for function in bsdconfig's `common.subr'.
+ Fix dialog auto-sizing when launched as an rvalue to a pipe for indirected
scripts (previously would default to 24x80 sizing in this case, now it can
autosize to full size even when in a pipe chain).
+ Fix bug in f_snprintf if $format argument began with "-"; printf would
misinterpret as a flag. (this is in bsdcofig's `strings.subr').
+ Add accompanying f_sprintf() and f_vsprintf() to go along with already
existing f_snprintf() and f_vsnprintf() (see bsdconfig's `strings.subr').
+ Remove some unnecessary default ZFS datasets from the automatic "zfsboot"
script. Such as: /usr/ports/distfiles /usr/ports/packages /usr/obj /var/db
/var/empty /var/mail and /var/run (these can all be created as-needed once
the system is installed).
+ Remove setuid=off for /usr/home (as discussed from last round of CFT).
+ Fix some i18n string violations in "zfsboot".
+ Bolster debugging output in "zfsboot".
+ Fix some string quoting issues in "zfsboot".
+ Fix some variable scope issues in "zfsboot".
+ Change "Create" to "Install" in "zfsboot" main menu.
+ Increase error checking in "zfsboot" (type-check arguments and such).
+ Add call to "graid destroy" killing automatic metadata (part of the series
of pedantic destructions we do when bootstrapping a new/naked disk).
+ Make judicious use of new f_eval_catch() in "zfsboot".
+ Fixup some variable names for consistency (zfsboot).
+ Fix an underride syntax parameter expansion folly (zfsboot).
+ Confirm layout if not explicitly chosen when blindly proceeding (no
longer have to touch anything on the ZFS menu if it scares you, just
choose the omnibus "Install" option at the top and you'll be prompted to
select vdev type and disks in the layout confirmation dialog).
+ Change numbered menu items to alphabetic for more efficient navigation.
+ Consolidate vdev selection and disk selection into a single stateful
menu which performs validation and allows backing out to each previous
menu as you go deeper.
+ Redesign the ``Last Chance'' dialog (still using the same colors, but
make it conform to a tolerable width and make disks appear in a block-
quote style indented region).
+ Fix a bug wherein we used the a lowercase variable name by accident
(actual variable name declared as all-uppercase) at the time of
initializing fstab(5) (not believed to cause any issues though).
+ Update the geli setup infobox for each provider being initialized
(not just at the onset -- since each ``geli init'' causes kernel messages
to push our infobox off-screen).
Reviewed by: Allan Jude <freebsd@allanjude.com>
Discussed on: -current
MFC after: 3 days
and OpenSolaris/Illumos beadm use.
Remove /usr/local and /var/db/pkg datasets. Andriy Gapon writes:
I want to note that a good implementation of BEs should support a dependent
datasets feature. Unfortunately, it seems that we do not have any good BE
implementation for FreeBSD right now. If we had, personally I'd prefer to
have /usr/local in separate filesystem.
NOTE: Until then, remove these datasets.
Discussed on: src-committers
Submitted by: Bryan Drewery <bryan@shatow.net>
Reviewed by: Allan Jude <freebsd@allanjude.com>
MFC after: 3 days
so bootpool is imported after boot:
zpool_cache_load="YES"
zpool_cache_type="/boot/zfs/zpool.cache"
zpool_cache_name="/boot/zfs/zpool.cache"
otherwise /boot is a broken symlink after the system is up.
http://lists.freebsd.org/pipermail/freebsd-fs/2013-July/017891.html
NOTE: Fix a comment while here.
Reviewed by: gjb
services configuration and enable it by default. Committed with
slight change to menu text for length and content.
Submitted by: Allan Jude <freebsd@allanjude.com>
Approved by: re (glebius)
Patch from PR modified slightly for whitespace and style.
PR: bin/161547
Submitted by: Warren Block <wblock@wonkity.com>
Reviewed by: Allan Jude <freebsd@allanjude.com>
Approved by: re (glebius)
keymaps *and* provide a mechanism for testing the selection. With
this commit, bsdinstall is no longer dependent on kbdmap(1). The
keymap test menu was originally submitted by Warren Block but was
modified).
Submitted by: Warren Block <wblock@wonkity.com>
Reviewed by: Allan Jude <freebsd@allanjude.com>
Approved by: re (glebius)
to run interactively but it can be scripted too (optinally completely
non-interactive). Currently supports GELI and all ZFS vdev types. Also
performs validation on selections/settings providing error messages if
necessary, explaining (in plain language) what the issue is. Currently
the auto partitioning of naked disks only supports GPT and MBR (VTOC8
pending for sparc64), so is only available for i386/amd64 install.
Submitted by: Allan Jude <freebsd@allanjude.com>, myself
Reviewed by: Allan Jude <freebsd@allanjude.com>
Approved by: re (glebius)
newly installed system. This should greatly increase the amount of
entropy available when SSH host keys are generated during first boot.
Reviewed by: markm, nathanw
Approved by: re (gjb)
directory on the FTP mirrors to fetch distributions, since
these are always pushed to releases/ during the release cycle.
MFC after: 3 days
X-MFC-To: stable/9, releng/9.2
This is a workaround, as for unknown yet reason the keys binded on the Partition Edition window are the one from partlist instead of the one from standard "formfield"
Reported by: alfred, nwhitehorn
media has one already, copy it in lieu of leaving things blank. This
reduces the foot-shooting potential for PXE installs that immediately
add packages.
type. GEOM provider names can't duplicate (or shouldn't -- devfs will either
break or only use the first one if they do) so using the first provider
by that name is a sufficient check. This also lets the scripted partitioner
install onto gmirror and geli and such things.
Scripts take the form:
------------------------------------
PARTITIONS=ada0
DISTRIBUTIONS="kernel.txz base.txz ports.txz"
#!/bin/sh
echo "sshd_enable=YES" >> /etc/rc.conf
pkg add puppet
echo "System setup complete"
------------------------------------
The second part of the script (beginning with #!) is run in the newly
installed system after the installation onto ada0 (with default partitioning,
see scriptedpart for more complicated scenarios) is complete.
will come soon. This lets the install process have a line like:
bsdinstall scriptedpart 'ada0 GPT {1.5G freebsd-ufs /, 10G freebsd-swap,
auto freebsd-ufs /usr}'
to set up a system with a 1.5GB /, some swap space, and a /usr using the
rest of ada0.
MFC after: 1 month
being run to set BSDINSTALL_DISTSITE accordingly. This change allows
non-RELEASE branches to use the FTP snapshots directory for bootonly.iso
installations.
Approved by: simon
containing whitespace. Also make other changes to support multi-word
arguments.
PR: bin/170759
Submitted by: dteske
Reviewed by: emaste (mentor)
Approved by: emaste (mentor)
MFC after: 3 days
any installer-provided configuration files have been copied. This allows
users to edit their fstab, if desired, and to see what the installer has
placed in rc.conf.
Requested by: phk
MFC after: 1 day
giving them a very brief description of the trade-offs. Whether the
user opts in or out add an entry to what will become /etc/rc.conf
explaining what dumpdev is and how to turn on/off crash dumps. The folks
who handle interacting with users submitting PRs have asked for this.
Reviewed by: nwhitehorn
MFC after: 1 day
the text of the menu selections doesn't get displayed properly and it
makes the installer appear to lock up for no obvious reason.
Reviewed by: nwhitehorn
creating new ones by destroying any geom that may have come into
existence immediately after adding a partition. The EBR partition scheme
is particularly enthusiastic about false positives in this case.
MFC after: 3 days
container partitions, which didn't do anything anyway, and check for
an existing freebsd-boot partition before bothering the user to make one.
PR: bin/160931
MFC after: 3 days
order to make every operation of the partition editor fully revertable.
Under *no circumstances* will it any longer touch the disks until the user
presses Finish and confirms it.
MFC after: 3 days
not configure the host's networking if netbooted [1]. Also fix FTP
installations behind some firewalls [2].
PR: bin/159583 [2]
Reported by: stas [1]
Approved by: re (kib)
wpa_supplicant.conf(5). Up to now, the PSK was truncated
to 15 characters (the length of the input field).
PR: 159559
Submitted by: Gavin Chappell <gavin.chappell@gmail.com>
Approved by: re (kib)
1) if no default gateway is given the route command will fail
and the script will abort with an error leading to an endless
loop unless configuration is cancelled or changed. [1]
2) In the IPv6 case add -inet6 to not alter the legacy IP default
route.
Reported by: Oleg Ginzburg (olevole olevole.ru) [1]
Tested by: Oleg Ginzburg (olevole olevole.ru) [1]
Approved by: re (kib)
This follows what the output of make targets looks like, and reduces the
number of directories needed on the FTP server, since we now have only one
architecture with multiple machine types (i386, which has i386 and pc98),
but 3 machines with 9 architectures between them (powerpc, mips, and arm).
Requested by: kensmith, bz
Approved by: re(kensmith)
you were stuck in an endless loop.
Reported by: kensmith
Approved by: re (kib) for BETA1
Pointy hat to: bz - wonder why I had not tested legacy IP thoroughly..
the normal distfile mechanism. Thanks to Marc Fonvieille for the patch and
for putting up with me taking entirely too long to commit this!
Submitted by: blackend
1) do not print out an empty "search ", things do not like it.
2) the search list is not comma separated.
Sponsored by: The FreeBSD Foundation
Sponsored by: iXsystems
to the final name if netconfig was completely finished. This fixes
reentrance problems even better than r222611.
Suggested by: nwhitehorn
Reviewed by: nwhitehorn
Sponsored by: The FreeBSD Foundation
Sponsored by: iXsystems
interface. Otherwise an accidental start of the netowrk configuration
and immediate cancel after the install has finished removes the previously
configured settings.
Discussed with: nwhitehorn
Sponsored by: The FreeBSD Foundation
Sponsored by: iXsystems
- netconfig - what auto will call which in turn will check for
IPv4 and IPv6 to be available and ask the user to configure it
by calling
- netconfig_ipv4 doing DHCP and static IPv4 addresses, and
- netconfig_ipv6 doing rtsol and static IPv6 addresses,
and then checking, querying and updating resolv.conf upon return.
Both DHCP and rtsol (in the future) might update resolv.conf already so
we seed ourselves from that file if available.
Reviewed by: nwhitehorn
Sponsored by: The FreeBSD Foundation
Sponsored by: iXsystems
Some files keep the SUN4V tags as a code reference, for the future,
if any rewamped sun4v support wants to be added again.
Reviewed by: marius
Tested by: sbruno
Approved by: re
does. The rc.local wrapper script will also soon grow an option to use the
live environment after installation, so an immediate reboot isn't even
necessarily implied.
(e.g. powerpc64), this looks in a slightly different default path than now,
specifying both $MACHINE and $MACHINE_ARCH:
MIRROR/pub/FreeBSD/releases/`uname -p`/`uname -m`/`uname -r`
How to handle TBEMD properly probably merits some more discussion, but,
since no such 9.0-CURRENT distfiles exist at the moment, all existing
mirrors presently fail anyway.
in the archive instead of spinning through it to get a file count for the
progress bar. This speeds up installation a lot on systems with slow
CD drives.