device. The details include the current value of the BAR (including all
the flag bits and the current base address), its length, and whether or not
it is enabled. Since this operation is not invasive, non-root users are
allowed to use it (unlike manual config register access which requires
root). The intention is that userland apps (such as Xorg) will use this
interface rather than dangerously frobbing the BARs from userland to
obtain this information.
- Add a new sub-mode to the 'list' mode of pciconf. The -b flag when used
with -l will now list all the active BARs for each device.
MFC after: 1 month
with identical meaning as the colon ":". This is to support a syntax
that is more similar to a PCI device specification in the device hints
file. The selector is not fully compatible with the specification in
the hints file, since entries in that file use a different prefix,
which needs to be added to the getsel() routine, if full support of
that syntax is found to be desirable.
Approved by: re (Ken Smith)
PCI selectors with 2 or 3 elements behave exactly as before (i.e. the
domain is 0 and in the 2 element case, the function is also 0).
The form with 4 selector elements works as in the previous revision
and provides the PCI domain number as the left-most selector element.
This change allows old scripts (which used the 2 or 3 selector element
formats) to be kept. Without this patch, the 3 element form was parsed
as starting with a domain number (and the function was assumed to be 0),
with this patch, the domain is assumed to be 0 (and the last value is
used as the function number).
The man page is updated to describe the new selector semantics.
Approved by: re (Ken Smith)
support machines having multiple independently numbered PCI domains
and don't support reenumeration without ambiguity amongst the
devices as seen by the OS and represented by PCI location strings.
This includes introducing a function pci_find_dbsf(9) which works
like pci_find_bsf(9) but additionally takes a domain number argument
and limiting pci_find_bsf(9) to only search devices in domain 0 (the
only domain in single-domain systems). Bge(4) and ofw_pcibus(4) are
changed to use pci_find_dbsf(9) instead of pci_find_bsf(9) in order
to no longer report false positives when searching for siblings and
dupe devices in the same domain respectively.
Along with this change the sole host-PCI bridge driver converted to
actually make use of PCI domain support is uninorth(4), the others
continue to use domain 0 only for now and need to be converted as
appropriate later on.
Note that this means that the format of the location strings as used
by pciconf(8) has been changed and that consumers of <sys/pciio.h>
potentially need to be recompiled.
Suggested by: jhb
Reviewed by: grehan, jhb, marcel
Approved by: re (kensmith), jhb (PCI maintainer hat)
via a new -c flag to be used with -l. Some simple parsing code is
present for the following capabilities: Power Management, AGP, VPD,
MSI, PCI-X, HyperTransport, Vendor-specific, EHCI Debug Port, PCI-PCI
bridge subvendor ID, PCI-express, and MSI-X.
- Fix a few warnings in pciconf.c.
- Update some cruft in pciconf(8):
- PCI 2.1 is no longer a revolutionary standard, and subvendor ID's are
fairly common at this point, so reflect that.
- Header type 2 is used for PCI-CardBus bridges.
- Describe the -v option for -l after completing the basic -l description
instead of disrupting the flow in the middle.
Reviewed by: imp (partially)
MFC after: 1 week
Trim trailing whitespace and comments before parsing, and skip empty lines.
Skip subvendor / subdevice entries (which start with two tab characters).
Change the scanf() format string to match any amount and type of whitespace
between the device ID and the description text.
MFC after: 3 weeks
and list_verbose(), so don't open /dev/pci read-write. This allows
pciconf -l[v] to work for non-root users, assuming the securelevel is
0 or -1.
Problem experienced by: William Michael Grim <wgrim@siue.edu>
synopsis, and the man page description ("selector" vs. "sel" and
"addr" vs. "reg").
Fix the usage message and man page synopsis to show that the "value"
argument is not optional.
- Read the database from /usr/share/misc (or wherever else we're pointed)
rather than compiling it in.
- Decode the class/subclass fields if requested.
- Print things in a slightly longer but more readable format.
background ]
Rename sys/pci/pci_ioctl.h to sys/sys/pciio.h to make it easier for
userland programs to use this interface. Reformat the file, and add a
BSD-style copyright to it.
Add a new man page for pci(4). The PCIOCGETCONF, PCIOCREAD, and PCIOCWRITE
ioctls are documented, but the PCIOCATTACHED ioctl is not documented
because it is not implemented.
Change includes of <pci/pci_ioctl.h> to <sys/pciio.h> or remove them
altogether. In many cases, pci_ioctl.h was unused.
Reviewed by: steve
configured in the kernel. It gives them a device name of "none" and
monotonically incrementing unit numbers. (starting at 0) Before, pciconf
would just skip over unconfigured devices. (unconfigured devices can be
detected because they have a null string for a device name)
Update the man page to reflect the new pciconf output. Unfortunately, this
causes the sample 'pciconf -l' output lines to wrap, but I'm not sure what
to do about that really.
If anyone presents a reasonable case for printing out something other than
"none1" for unconfigured devices, I'm willing to listen.
Add printing of PCI header type register. (This makes the output
80 columns wide. Ughh. I'm looking for a better way to put the
information on one line ...)