Commit Graph

4120 Commits

Author SHA1 Message Date
dougb
30a481575c Fix some of the more egregious problems with this file:
1. Update text about later BINDs using a pseudo-random, unpriviliged
query port for UDP by default.

2. We are now running in a sandbox by default, with a dedicated dump
directory, so remove the stale comment.

3. The topology configuration is not for the faint of heart, so
remove the commented example.

4. Tighten up some language a bit.

5. s/secondary/slave/

6. No need for the example about a bind-owned directory for slave zones.

7. Change domain.com to example.com in the example, per RFC 2606.

8. Update the path for slave zones in the example.
	- Thanks to Scot Hetzel <swhetzel@gmail.com>

There is more work to do here, but this is an improvement.
2004-09-28 21:22:09 +00:00
dougb
8ab73bd19f Create a named chroot directory structure in /var/named, and use it
by default when named is enabled. Also, improve our default directory
layout by creating /var/named/etc/namedb/{master|slave} directories,
and use the former for the generated localhost* files.

Rather than using pax to copy device entries, mount devfs in the
chroot directory.

There may be some corner cases where things need to be adjusted,
but overall this structure has been well tested on a production
network, and should serve the needs of the vast majority of users.

UPDATING has instructions on how to do the conversion for those
with existing configurations.
2004-09-28 09:46:00 +00:00
dougb
0401e4773b 1. Add much finer granularity to the NO_BIND knobs with the addition of:
NO_BIND_DNSSEC, NO_BIND_ETC, NO_BIND_NAMED, and NO_BIND_UTILS.

2. Make creation of directories in /usr/include that are only needed
in the WITH_BIND_LIBS case conditional.

Reviewed by:	ru, des
2004-09-27 08:23:43 +00:00
dougb
484e210e44 Remove the directories that are now only installed when the user
defines WITH_BIND_LIBS.
2004-09-27 08:18:43 +00:00
dougb
716964fb64 Hook the BIND.* files up to the build. 2004-09-27 08:17:51 +00:00
dougb
f81fecb825 Seperate out the optional parts of the include tree that are
only built and installed when the user defines WITH_BIND_LIBS.
2004-09-27 08:16:29 +00:00
dougb
761f40ae09 Add a file spec to create a chroot directory structure for
a BIND name server.

This file is not being used yet, but will be soon.
2004-09-27 08:15:34 +00:00
dougb
92f6cf693b This file is about to get some optional bits, so line up the parts of
the FILES variable one line at a time.

This should be a whitespace change only.

Reviewed by:	ru
2004-09-27 07:00:44 +00:00
dougb
17e16850dd It's not necessary to create an rndc.key file if the user already
has an rndc.conf file.

Submitted by:	Sergey Mokryshev <mokr@mokr.net>
2004-09-26 07:01:56 +00:00
des
5d5a77e0c8 Create /etc/namedb/bind with owner / group bind and mode 0750. 2004-09-25 15:55:17 +00:00
dougb
a0c8ba71f0 Install the documentation for bind9, and remove the /usr/share/doc/bind
directory from mtree while we're at it.

Help, advice, and code from:	ru, des
2004-09-25 00:42:38 +00:00
dougb
b2045c7beb Fix two glitches that appear in the non-chroot case. First, if not
chrooted the pid symlink code should not fire. Also, remove the quotes
around the chroot variable in the rndc-confgen invocation so that if
not chrooted the command will still succeed.

Pointed out by:	Sean McNeil <sean@mcneil.com>
2004-09-24 23:49:38 +00:00
dougb
1d7bcd07a4 For the default FreeBSD install, the file path actually is
/var/run/named/pid. This is done so that named can start
with -u bind and still dump a pid file in that directory,
which is chowned to user bind.
2004-09-24 22:47:10 +00:00
des
baf85aea0d It's named.pid, not named/pid.
Pointy hat to:	dougb@
2004-09-24 19:46:18 +00:00
des
d7ad9b3a1e Reconnect namedb. While it may not be optimal, our old named.conf from
BIND 8 is quite usable for BIND 9.
2004-09-24 16:13:55 +00:00
cognet
bc4c368763 Add ttyu0 as a serial console, as we're using the uart(4) driver on arm. 2004-09-24 12:51:15 +00:00
keramida
b0d44faf34 Fix a comment typo: s/neccessary/necessary/ 2004-09-24 11:04:27 +00:00
dougb
59fb2964ab Update to reflect BIND 9 in the base:
1. Making the pid symlink now has to happen after named starts, otherwise
it can generate a fatal error.

2. named-xfer is not part of the BIND 9 world.

3. BIND 9 needs a /dev/random in the chroot directory if chrooted.

4. Only the pid file is symlinked now, the ndc socket is BIND 8 only.

5. Create an rndc.key file for the user if one does not exist.
This (generally) allows a BIND 8 config file to be used in a BIND 9
world with little or no modification.
2004-09-24 04:53:18 +00:00
dougb
a2569080d2 Add a note to indicate that the path set in named_pidfile must
also be set in named.conf. Our default named.conf has this already.

Update the note for named_symlink_enable to indicate that ndc is gone.
2004-09-24 04:45:16 +00:00
des
6cf834cbc7 Re-add namedb. I misunderstood what Doug said about using ISC's
layout: he meant for binaries, not configuration files.
2004-09-23 19:33:54 +00:00
jkoshy
0db2ef85c6 Add a knob 'daily_status_security_diff_flags' controlling the
format of the 'diff' output generated during periodic(8) scripts.

Submitted by:	keramida (script changes)
Reviewed by:	keramida (man page changes)
2004-09-23 02:00:52 +00:00
des
be8d367a6b Switch from BIND 8 to BIND 9.
Submitted by:	(in part) dougb@, trhodes@
Reviewed by:	dougb@, trhodes@, re@
MFC after:	5 days
2004-09-21 19:01:48 +00:00
des
c42b81ff1a If $dumpdev is set to AUTO, use the first suitable swap partition listed
in /etc/fstab, or print an error message if no suitable device was found.

MFC after:	4 weeks
2004-09-20 17:48:45 +00:00
pjd
345f6896ef Teach swap1 script how to remove added swap devices on system shutdown.
Without this change, if one had a swap-on-mirror configuration, gmirror
will rebuild mirror component(s) on boot, because they are dirty (they
were open on shutdown).
2004-09-17 17:58:19 +00:00
glebius
a4c137b95e Change tabs to whitespaces.
Noticed by:	ru
Pointy hat to:	glebius
2004-09-16 21:33:56 +00:00
glebius
98751193f5 Install netflow includes.
Approved by:	julian (mentor)
2004-09-16 20:42:03 +00:00
keramida
d31ccbedc9 We don't have any providers of `beforenetlkm' in FreeBSD. Remove the
dependency to it from our rc.d scripts.

Approved by:	mtm
2004-09-16 17:04:20 +00:00
keramida
b76c8230d8 Fix requirement of network' to NETWORK' because the former isn't
provided by any rc.d script.

Approved by:	mtm
2004-09-16 17:03:12 +00:00
seanc
c21072f9bb Bring back etc/rc.d/ntpdate as requested by scads of people. This isn't a
complete backout as the ntpd_sync_on_start etc/rc.conf tunable is still
present, though the default is now NO (was YES).  Since we're no longer
syncing time at startup by default when ntpd is enabled (as was the case
24hrs ago), remove UPDATING entry pointing out that ntpd(1) -g is slower
than ntpdate(1).

Hopefully ntpd_sync_on_start="YES" can be made the default for -CURRENT
after 5.3 is cut.  At the very least, this should be set to YES when a
user requests to have ntpd enabled via sysinstall(1).

Requested by:	many
2004-09-15 01:08:33 +00:00
seanc
17e6f7addb Stop using ntpdate(1) in our startup procedure. Replace ntpdate(1) with
calls to ntpd -g.  ntpd is noticeably slower than ntpdate, but is also more
accurate.  This removes the nasty hackery in rc.d/ntpdate that would parse
out ntp servers from /etc/ntp.conf (ntpd knows how to read its own config
file).  By default, ntpd *will* sync with its listed time servers.  To
turn this off so that ntpd does not sync, ntpd_sync_on_start="NO" can be
added to /etc/rc.conf.  If ntpd is not enabled (the default), then time is
not synced on startup.  ntpdate has been depreciated by the ntpd authors
for quite some time so this change shouldn't be unexpected.

Suggested by:	des
Approved by:	roberto (resident ntp guru)
2004-09-14 03:04:50 +00:00
seanc
44d9344750 Stop using ntpdate(1) in our startup proceedure. Replace ntpdate(1) with
calls to ntpd -g.  ntpd is noticably slower than ntpdate, but is also more
accurate.  This removes the nasty hackery in rc.d/ntpdate that would parse
out ntp servers from /etc/ntp.conf (ntpd knows how to read its own config
file).  By default, ntpd *will* sync with its listed time servers.  To
turn this off so that ntpd does not sync, ntpd_sync_on_start="NO" can be
added to /etc/rc.conf.  If ntpd is not enabled (the default), then time is
not synced on startup.  ntpdate's use has been depreciated by the ntpd
authors for quite some time so this change shouldn't be unexpected.

Suggested by:	des
Approved by:	roberto (resident ntp guru)
2004-09-14 03:01:38 +00:00
mlaier
00628d6214 Bring in some examples (and create space for future work here):
- Add OpenBSD example rulesets as advertised in etc/pf.conf and pf.conf(5)
- Tweak the pointer to fit the FreeBSD default location share/examples/pf
- Account for the new directory in BSD.usr.dist (no hier(7) change required
  as share/examples is an opaque item there).

Obtained from:	OpenBSD
Reminded by:	Thomas T. Veldhouse
PR:		docs/71691
MFC after:	2 days
2004-09-14 01:07:19 +00:00
mlaier
e6c9376e71 Update the passive OS fingerprint database from OpenBSD.
Obtained from:	lcamtuf.coredump.cx (via OpenBSD)
2004-09-14 00:30:14 +00:00
ru
53a474f697 A power failure left the temporary /var/.diskless directory
on my system, and since then my /var was always created as
MFS which was very surprising.  Fix this for /tmp and /var.
2004-09-13 17:40:14 +00:00
wpaul
48fb8b1bcf Add device driver support for the VIA Networking Technologies
VT6122 gigabit ethernet chip and integrated 10/100/1000 copper PHY.
The vge driver has been added to GENERIC for i386, pc98 and amd64,
but not to sparc or ia64 since I don't have the ability to test
it there. The vge(4) driver supports VLANs, checksum offload and
jumbo frames.

Also added the lge(4) and nge(4) drivers to GENERIC for i386 and
pc98 since I was in the neighborhood. There's no reason to leave them
out anymore.
2004-09-10 20:57:46 +00:00
obrien
afd2dfa682 Restore NetBSD SCM ID.
Submitted by:	delphij@beastie.frontfree.net
2004-09-09 16:41:55 +00:00
glebius
77691a3fee Add axe(4) to ethernet-nic-regex.
PR:		conf/71410
Submitted by:	Andrew Thompson <thompsa AT thingy.tbd.co.nz>
Approved by:	julian (mentor)
MFC after:	3 days
2004-09-06 20:09:00 +00:00
alfred
d368f29686 Hook autofs to the build. 2004-09-02 20:44:56 +00:00
brooks
b0273ba671 When an USB keyboard is plugged in to a machine with a builtin keyboard,
cause the USB keyboard to take over from the builtin one.  This means my
laptop just works when I'm using it as a desktop.

Reviewed by:	imp
2004-09-01 00:08:15 +00:00
mlaier
a95ab76a03 Don't rely on properly setup linker.hints to figure out that pflog is now
part of the pf module.
While here fix a comment that was c'n'ped from rc.d/pf

PR:		bin/71096 (partly)
Submitted by:	Ville-Pertti Keinonen
MFC after:	2 days
2004-08-31 14:23:51 +00:00
kensmith
4cdf4d5c87 Protect the command flags set in the rc.conf files in case they're
more than one word, adding some quotes.

Advice from:	mtm (my first attempt wasn't quite right)
Reviewed by:	mtm
MFC after:	3 days
2004-08-29 15:02:43 +00:00
tjr
d8cea4a43d Add Basque (Spain) locales: eu_ES.ISO8859-1, eu_ES.ISO8859-15, eu_ES.UTF-8.
(This differs somewhat from the version originally submitted - any mistakes
are my own.)

PR:		68524
Submitted by:	J. Vicente Carrasco -Bixen-
2004-08-28 12:52:31 +00:00
yar
ce4ac6d262 Avoid double appearing of cloned interfaces in the output
from list_net_interfaces() when network_interfaces=auto.

Rationale: Since the auto case is special, the lesser evil
had to be chosen among not adding cloned interfaces to
_tmplist or removing duplicates from _tmplist after adding
cloned interfaces.  Since list_net_interfaces() must not use
/usr/bin tools, the former "evil" appeared clearer and much
more efficient.  (See the PR audit trail for discussion.)

PR:		conf/63700
Reviewed by:	brooks
MFC after:	5 days
2004-08-28 07:58:02 +00:00
yar
fc94d686c9 Fix a typo in a variable name. 2004-08-27 12:11:47 +00:00
ru
0f454509cf share/examples/worm is dead. 2004-08-24 19:03:55 +00:00
des
b89948f3fa Always quote variables in tests, to ensure correct evaluation even when
they are empty or undefined.

MFC after:	3 days
2004-08-19 08:55:24 +00:00
thomas
c77da11cc6 Skip entries for GBDE swap devices if they are commented out in /etc/fstab.
Reviewed by:	des
2004-08-18 21:54:40 +00:00
nectar
b7d4f83f1c Create temporary files safely.
Submitted by:	Jon Passki <cykyc@yahoo.com>
2004-08-16 16:37:06 +00:00
cperciva
118632bcd7 Add 3653/tcp and 3653/udp, since they were specifically requested.
PR:		conf/63907
Submitted by:	Marc Blanchet
MFC after:	3 days
2004-08-16 11:52:22 +00:00
dwmalone
f8f65bb48e Add Hungarian calendar entries.
PR:		42725
Submitted by:	Janos Mohacsi <janos.mohacsi@bsd.hu>
2004-08-16 09:31:09 +00:00
pjd
451db872cf Connect RAID3 GEOM class to the build. 2004-08-16 06:36:21 +00:00
gshapiro
e748eb242a Fix the startup logic for sendmail. If sendmail_enable=yes, don't start
the submit and outbound daemon, else if sendmail_submit_enable=yes, don't
start the outbound daemon.  Only one daemon should be started.

Also, do not rebuild database maps at boot time.  The code didn't pay
attention to SENDMAIL_MAP_TYPE and assumed 'hash'.  Also, admins may
not want maps automatically rebuilt just because the back end database
has changed.  Finally, some maps are built with mode tools than just
makemap (e.g., using cidrexpand on the access text file before sending
it to makemap).

Noticed by:	ache
Reviewed by:	ache
2004-08-05 03:09:54 +00:00
markm
7a1da9e0e3 Give sshd a secure startup, but with a tweakable timeout so that
the box won't hang forever at startup.
2004-08-04 08:10:37 +00:00
ume
890d27a1e8 Use RFC 3849 address for examples.
Pointed out by:	mistral@imasy.or.jp
MFC after:	1 week
2004-08-03 08:58:34 +00:00
ume
28fa3dc5e6 allow ::1 explicitly.
Pointed out by:	mistral@imasy.or.jp
MFC after:	1 week
2004-08-03 08:47:35 +00:00
markm
b7ad26717b UUCP's uucico(8) has not been in the base system for some time now,
so reflect this in the default. The uucp uid is a bit funny, and
is used by mtree in /var/spool for locks, so we can't remove it
without thinking about it a bit harder.
2004-08-01 21:33:47 +00:00
pjd
bbe86f8681 Connect GEOM_MIRROR class to the build. 2004-07-30 23:18:53 +00:00
mtm
d6990401f5 Finish cleanup of rc.d/netif. It's now possible to start/stop more
than one interface from the command line:
	# /etc/rc.d/netif start bfe0 xl0
It's also possible to restart an interface(s):
	# /etc/rc.d/netif restart bfe0

This required some changes to rc.subr(8) so that if the start/stop commands
are overidden the rest of the command line (after the start/stop/etc... cmd)
is passed through to the subroutines.
2004-07-30 17:19:35 +00:00
kan
52952ef9d1 Bmake glue for GCC 3.4.2-prerelease. 2004-07-28 05:27:21 +00:00
eik
2e5d35656d back out the localkg changes until things have settled.
Discussed with:	mtm
2004-07-28 00:09:19 +00:00
mtm
bf55ef7124 Even though binaries will give 0 matches, make it explicit. 2004-07-27 16:59:35 +00:00
ru
fa2bf654be Fixed style of previous commit. 2004-07-27 12:31:38 +00:00
mlaier
27b2144dbf Fix typo in description of pflog_logfile.
Submitted by:	Mike Jakubik
2004-07-27 00:28:16 +00:00
mtm
c415b9b014 Correct typo.
Submitted by: eik (and probably many others)
2004-07-24 16:30:31 +00:00
mtm
f23e3c4154 Ports related rc.d cleanups:
o Separate out local (ports) scripts that use rc.d, and the old style
  startup/shutdown scripts and execute them separately. On startup the
  rc.d style scripts are executed first and then the old-style scripts.
  On shutdown, exactly the reverse happens.
o The rc.d ports scripts should now behave more like base system scripts.
  Scripts ending in .sh will be sourced into the current shell, while the
  rest will be executed in a subshell. Previously, all ports scripts,
  regardless of the .sh suffix, were executed in a subshell.
o The parent script, /etc/rc.d/localpkg, passes its command line arguments
  straight to the rc.d ports scripts. This means they should now honor
  faststop and faststart commands as well. Old style scripts, should not see
  any differences. They will still get either a start or stop command.
o The initial phrase shown during shutdown has been changed to use
  "local packages" instead of "daemon processes" to be more inline with the
  phrase used during local package startup. The phrases are also used only for
  old-style ports script startup/shutdown, whereas previously they were being
  used for both rc.d and old-style scripts. This should make startup/shutdown
  output a bit less ugly.

Discussed with:	portmgr
Has Reservations: eik
2004-07-24 14:56:21 +00:00
roberto
b549f2ea58 Add /etc/ntp to hold keys for ntpd. 2004-07-21 10:14:10 +00:00
simon
63130b410f For the gbde attach script:
- Ask the user up to X times (3 by default) for the pass-phrase, if
  it is incorrect the first time.
- Add support for storing the lockfiles in another other directory
  than /etc.
- Document that it is possible to override the location of each single
  lockfile.

Approved by:	pjd
2004-07-18 18:01:48 +00:00
cperciva
9fe6a4d735 Whitespace cleanup. This will simplify a future merge from
IANA's official list of port assignments.
2004-07-11 19:20:47 +00:00
harti
a268ce68fc Add a directory for the API include files. 2004-07-08 16:48:43 +00:00
cperciva
d5c6e77e9c Sort entries correctly. 2004-07-07 06:15:32 +00:00
imp
9cfff038cf Disable rescanning of the scsi bus for the scsi controllers. There
are some that really hate this, so now that devd is default, be more
conservative about what we do.

Noticed by: marcel
2004-07-05 20:16:30 +00:00
cperciva
a5ec3efb16 Wrap rc.subr inside
if [ -z "${_rc_subr_loaded}" ]; then
_rc_subr_loaded="YES"
...
fi

in order to avoid re-interpreting rc.subr every time an rc.d
script is run.  In my tests, this speeds up rc time by about
8-10%.
2004-07-04 07:21:18 +00:00
pjd
3ad94a6543 Introduce GEOM_LABEL class.
This class is used for detecting volume labels on file systems:
UFS, MSDOSFS (FAT12, FAT16, FAT32) and ISO9660.
It also provide native labelization (there is no need for file system).

g_label_ufs.c is based on geom_vol_ffs from Gordon Tetlow.
g_label_msdos.c and g_label_iso9660.c are probably hacks, I just found
where volume labels are stored and I use those offsets here,
but with this class it should be easy to do it as it should be done by
someone who know how.
Implementing volume labels detection for other file systems also should
be trivial.

New providers are created in those directories:
/dev/ufs/ (UFS1, UFS2)
/dev/msdosfs/ (FAT12, FAT16, FAT32)
/dev/iso9660/ (ISO9660)
/dev/label/ (native labels, configured with glabel(8))

Manual page cleanups and some comments inside were submitted by
Simon L. Nielsen, who was, as always, very helpful. Thanks!
2004-07-02 19:40:36 +00:00
maxim
a8932ce967 Add user _pflogd. 2004-06-30 16:47:08 +00:00
imp
d1b8e75b8d devd is now on by default
Reviewed by: dfr,njr (not nate!)
2004-06-30 15:58:46 +00:00
mtm
424e6e539c Make the stop command respect the 'fast' prefix.
Most notably, this cleans up messages when shutting down from
single user. In such a case there are usually no daemons running,
but their pid files are still in /var/run. This causes rc.d to
output diagnostics about daemons with pidfiles, but that are
not running.
2004-06-26 09:27:30 +00:00
mtm
3bb6cc86e5 Fix typo.
Submitted by: kuriyama
2004-06-24 16:57:49 +00:00
mlaier
724caf6adc It's /usr/sbin/nologin not /sbin/nologin
Found-by:	brueffer
Pointy-hat-to:	mlaier
2004-06-23 09:42:19 +00:00
mlaier
648344e20f Swap order of ruleset load and enabling pf to work around a problem on altq
startup. Moreover, this is the "more logic" order.
2004-06-23 01:42:06 +00:00
mlaier
ee21394537 Add "privsep" user/group _pflogd:_pflogd (64:64) to make pflogd(8) work
again. This user/group is not required for install* targets, hence do not
add them to CHECK_UIDS/CHECK_GIDS in Makefile.inc1 (no need to annoy
people).

Discussed-on:	-current
2004-06-23 01:32:28 +00:00
des
1738b4c7db Correct an error carried over from the nsswitch.conf(5) manual page; add
a note to UPDATING since users may have to manually remove an incorrect
nsswitch.conf.

Noticed by:	simon
2004-06-21 19:38:58 +00:00
green
317bebaa99 Allow setting the system console keyboard via the ${keyboard} rc.conf
directive.
2004-06-18 20:09:30 +00:00
mlaier
7922e2ad84 Link ALTQ to the build and break with ABI for struct ifnet. Please recompile
your (network) modules as well as any userland that might make sense of
sizeof(struct ifnet).
This does not change the queueing yet. These changes will follow in a
seperate commit. Same with the driver changes, which need case by case
evaluation.

__FreeBSD_version bump will follow.

Tested-by:	(i386)LINT
2004-06-13 17:29:10 +00:00
cognet
ec4dcc5b14 Import the ttys file for arm.
make TARGET_ARCH=arm world now works (but still with external patches for
the toolchain bits).
2004-06-11 15:37:49 +00:00
obrien
7a1212a9ab Back out rev 1.3.
This is one of the few RC scripts that doesn't use rc.subr, and thus
doesn't source rc.conf. :-(
2004-06-08 19:53:25 +00:00
obrien
ed01b67e08 Don't assume everyone's /etc/[default/]rc.conf 'entropy_file' is "/entropy". 2004-06-07 09:16:19 +00:00
mtm
78600b9c21 Restore pre-rcNG behaviour:
SIGINT (Ctrl-c) kills the current script
SIGQUIT (Ctrl-\) kills /etc/rc (dropping you into single-user)

Prodded by:	harti
2004-06-06 18:06:09 +00:00
gshapiro
efccedda6d Remove trailing space.
Submitted by:	jens
2004-06-06 17:28:31 +00:00
schweikh
92dd778dc4 Removed whitespace at BOF, EOL & EOF. 2004-06-06 11:46:29 +00:00
sanpei
5a9c6344fe fix MELCO LPC3-TX entry.
I mistaked at 1.166.

Submitted by:	SARUMARU Yoshihiko <mistral@imasy.or.jp>
Pointed out by:	MORIYASU Hirano <m-hirano@konsei.co.jp>
	FreeBSD-users-jp 79808
	FreeBSD-users-jp 79816
2004-06-05 06:11:54 +00:00
ume
d75db5871b fix typo in comment in my previous commit. 2004-06-02 09:58:18 +00:00
ume
13dc08685f Add ip6addrctl_enable and ip6_addrctl_verbose option. If
ip6addrctl_enable is set to YES, address selection policy is installed
into kernel.
If there is /etc/ip6addrctl.conf, it is used for address selection
policy.  Even if there is no /etc/ip6addrctl.conf, we install default
policy.  In this case, if ipv6_enable is set to YES, we use address
selection policy described in RFC 3484 as default.  Otherwise, we
install priority policy for IPv4 address.
The default of ip6addrctl_enable is NO for now.  However, it may
better to enable it by default.
2004-06-02 09:39:49 +00:00
kris
8de60483f6 Add common share/locale directories (everything used by >= 5 ports [1]) and
/usr/local/www

[1] Semi-arbitrary cutoff, but I didn't want to add every locale directory
    used by ports, because a lot are only used by one or two, and it's less
    intrusive for these ports to just clean up after themselves.

MFC after:	2 days
2004-05-31 07:34:40 +00:00
njl
55869c4c7f Throw the switch and enable use of the lowest idle states while online in
addition to offline.  This can be overridden in /etc/rc.conf if it causes
trouble although this has been stable since 2003/12.
2004-05-29 04:52:37 +00:00
mlaier
cb58239b71 Add ftp-proxy 8021/tcp in order to make the inetd.conf entry actually work.
Submitted-by:	brueffer
Approved-by:	bms(mentor)
2004-05-27 23:42:26 +00:00
des
93b2e9477e Install nsswitch. 2004-05-24 14:17:19 +00:00
des
2ff453adca If nsswitch.conf does not exist, create it with the default settings.
The reason for doing this is that (at least some) 4.x binaries are very
unhappy if host.conf does not exist, and if we create host.conf but not
nsswitch.conf, nsswitch.conf will be created at the next reboot, so it
is better to create a correct nsswitch.conf right away.
2004-05-24 11:53:26 +00:00
des
79a2efb9a9 Move the task of updating nsswitch.conf / host.conf into a separate
script called nsswitch.
2004-05-24 11:48:58 +00:00
ume
20202ff45a drop packet which has ::1 as src or dst via other than lo0
like as rc.firewall does.

MFC after:	1 week
2004-05-24 07:27:26 +00:00
mtm
79211ee781 Really remove the return statement this time. Thanks to
ru for noticing.
2004-05-20 15:53:49 +00:00