data changes.
cam_ccb.h: Add a new advanced information type, CDAI_TYPE_RCAPLONG,
for long read capacity data.
cam_xpt_internal.h:
Add a read capacity data pointer and length to struct cam_ed.
cam_xpt.c: Free the read capacity buffer when a device goes away.
While we're here, make sure we don't leak memory for other
malloced fields in struct cam_ed.
scsi_all.c: Update the scsi_read_capacity_16() to take a uint8_t * and
a length instead of just a pointer to the parameter data
structure. This will hopefully make this function somewhat
immune to future changes in the parameter data.
scsi_all.h: Add some extra bit definitions to struct
scsi_read_capacity_data_long, and bump up the structure
size to the full size specified by SBC-3.
Change the prototype for scsi_read_capacity_16().
scsi_da.c: Register changes in read capacity data with the transport
layer. This allows the transport layer to send out an
async notification to interested parties. Update the
dasetgeom() API.
Use scsi_extract_sense_len() instead of
scsi_extract_sense().
scsi_xpt.c: Add support for the new CDAI_TYPE_RCAPLONG advanced
information type.
Make sure we set the physpath pointer to NULL after freeing
it. This allows blindly freeing it in the struct cam_ed
destructor.
sys/param.h: Bump __FreeBSD_version from 1000005 to 1000006 to make it
easier for third party drivers to determine that the read
capacity data async notification is available.
camcontrol.c,
mptutil/mpt_cam.c:
Update these for the new scsi_read_capacity_16() argument
structure.
Sponsored by: Spectra Logic
Modified submitter's original patch to reference why this is broken and what to do to work around the issue.
Submitted by: hubert@tournier.org
PR: bin/147572
Reviewed by: jhb
MFC after: 2 weeks
mpt(4) controller. Previously, the code assumed that multiple match
patterns provided to an XPT_DEV_MATCH request were ANDed together.
Instead, they are ORed. Instead, to match peripherals for a specific bus,
one query needs to be performed to lookup the path ID of the bus. A second
query can then be performed matching peripherals attached to that path.
This approach also makes the code a bit cleaner as the returned match
results do not mix bus and perphierals.
Reported by: several folks
MFC after: 1 week
present. mpt(4) controllers that do not support RAID do not have an IOC6
page, for example.
- Correct a check for a missing page error in a debug function.
MFC after: 1 week
Drive and controller status can be reported, basic attributes changed,
and arrays and spares can be created and deleted.
Approved by: re
Obtained from: Yahoo! Inc.