0fe200d953
event from mii(4) may not be delivered if valid link was already established. To address the issue, check current link state after driving MII_TICK. This should fix a regression introduced in r185753 on fast ethernet controllers. Reported by: csjp, Bruce Cran < bruce <> cran DOT org DOT uk > Tested by: csjp, Bruce Cran (initial version) |
||
---|---|---|
.. | ||
if_re.c |