150 lines
5.8 KiB
Groff
150 lines
5.8 KiB
Groff
.\"
|
|
.\" Copyright (c) 1995 HD Associates, Inc.
|
|
.\" All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer in the
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
.\" 3. All advertising materials mentioning features or use of this software
|
|
.\" must display the following acknowledgement:
|
|
.\" This product includes software developed by Christopher G. Demetriou.
|
|
.\" 3. The name of the author may not be used to endorse or promote products
|
|
.\" derived from this software withough specific prior written permission
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
|
|
.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
|
.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
|
|
.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
|
|
.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
|
|
.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
.\"
|
|
.\"
|
|
.rm ES
|
|
.rm EE
|
|
.de ES
|
|
.Pp
|
|
.nf
|
|
.in +0.5i
|
|
..
|
|
.de EE
|
|
.in -0.5i
|
|
.fi
|
|
..
|
|
.Dd April 26, 1995
|
|
.Dt LABPC 4 i386
|
|
.Os FreeBSD
|
|
.Sh NAME
|
|
.Nm labpc
|
|
.Nd
|
|
National Instruments LABPC and LABPC+ driver
|
|
.Sh SYNOPSIS
|
|
.Cd "device labpc0 at isa? port 260 tty irq 5 vector labpcintr
|
|
.Sh DESCRIPTION
|
|
This supports the National Instruments LABPC and LABPC+ \fILow-Cost
|
|
Multifunction I/O Board\fP.
|
|
.Pp
|
|
This board provides 8 12 bit A-D input channels, 2 12 bit D-A output
|
|
channels, and 3 8 bit digital I/O ports. It also supports setting
|
|
up the National Instruments SCXI bus off the digital I/O ports,
|
|
although that software is currently present in an external program
|
|
and not as part of the driver.
|
|
.Pp
|
|
The selection of the input or output device, mode, and channel is
|
|
through the minor number:
|
|
.ES
|
|
The 8 bit minor number format is UUSIDCCC, with
|
|
UU: Board unit.
|
|
S: SCAN bit for scan enable.
|
|
I: INTERVAL for interval support
|
|
D: 1: Digital I/O, 0: Analog I/O
|
|
CCC: The channel selector:
|
|
ANALOG:
|
|
input: channel must be 0 to 7 for AD0 ... AD7
|
|
output: channel must be 0 to 2
|
|
0: D-A 0
|
|
1: D-A 1
|
|
2: Alternate channel 0 then 1
|
|
|
|
DIGITAL:
|
|
input: Channel must be 0 to 2.
|
|
output: Channel must be 0 to 2.
|
|
.EE
|
|
.Pp
|
|
The /dev/MAKEDEV script will make the basic analog and digital
|
|
devices if you do "sh MAKEDEV labpcaio" and "sh MAKEDEV labpcdio",
|
|
however, it won't make device entries for INTERVAL and SCAN devices.
|
|
SCAN devices automatically scan over all channels from the channel
|
|
number down to 0 (for example, a SCAN for /dev/ad7 will read channels
|
|
AD7 ... AD0) while the INTERVAL device will wait for an external
|
|
signal and then read all the channels from the selected channel
|
|
number down to 0 as fast as it can. This is done by the hardware
|
|
and not the driver (other than turning it on); See the \fILabPC+
|
|
User's Manual\fP and the source code if this doesn't make sense to
|
|
you.
|
|
.Pp
|
|
The driver supports several general analog I/O ioctl calls. These
|
|
are defined in sys/dataacq.h and are intended to be implemented in
|
|
other data acquisition board device drivers.
|
|
.Pp
|
|
AD_MICRO_PERIOD_SET takes a pointer to a long argument specifying
|
|
the number of microseconds between samples.
|
|
.Pp
|
|
AD_MICRO_PERIOD_GET takes a pointer to a long argument and returns
|
|
the current number of microseconds between samples.
|
|
.Pp
|
|
AD_NGAINS_GET takes a pointer to an integer and returns the number
|
|
of different gain settings the board supports. This is 8 for the
|
|
LabPC board.
|
|
.Pp
|
|
AD_NCHANS_GET takes a pointer to an integer and returns the number
|
|
of channels the board supports. This is 8 for the LabPC board.
|
|
.Pp
|
|
AD_SUPPORTED_GAINS returns an array of NGAINS (the number obtained
|
|
by AD_NGAINS_GET) doubles. These are the gains the board supports.
|
|
.Pp
|
|
AD_GAINS_SET takes an array of NCHANS (the number obtained by
|
|
AD_NCHANS_GET) integers and sets the board gains. These are indices
|
|
into the supported gain array, with one gain for each channel.
|
|
.Pp
|
|
AD_GAINS_GET takes an array of NCHANS (returned by AD_NCHANS_GET)
|
|
integers and returns the cuurrent board gains.
|
|
.Sh BUGS
|
|
In general, only those capabilities that I needed are present. In
|
|
particular the following notable restrictions are present.
|
|
.Pp
|
|
The analog input is only supported in a clocked conversion mode.
|
|
.Pp
|
|
You can only set the sample clock down to 15 Hz. Anything slower
|
|
needs a modification to the driver to support TCINTEN in order to
|
|
chain together the counters to get a lower clock rate.
|
|
.Pp
|
|
There is no support for clocked D-A output.
|
|
.Pp
|
|
The 8255 providing the digital I/O ports is supported only in mode
|
|
0 (three 8 bit ports).
|
|
.Pp
|
|
There is support for the SCXI bus off the LABPC board. It is not
|
|
in the driver but is a separate user process that accesses the
|
|
digital I/O devices. Ask dufault@hda.com for it.
|
|
.Pp
|
|
MAKEDEV only makes the "basic" devices. You must make the INTERVAL
|
|
or SCAN devices by hand.
|
|
.Pp
|
|
The INTERVAL device sets the clock rate as high as possible so that
|
|
it samples all the channels as quickly as it can after the external
|
|
signal. This is a silly restriction; it should simply use the
|
|
clock setting.
|
|
.Sh CAVEATS
|
|
National Instrument's (like most other laboratory grade board
|
|
vendors) definition of Low-Cost differs dramatically from many on
|
|
the net.
|