freebsd-dev/contrib/bsnmp
Enji Cooper 2e590d595e Use calloc instead of malloc with buffers in snmp_{recv,send}_packet
This doesn't fix the issue noted in the PR, but at the very least it
cleans up the error so it looks a bit more sane, and in the event
that bsnmp did wander off into the weeds, the likelihood of it
crashing with more sensible output is greater, in my opinion

MFC counter set high so I have enough time to resolve the real
underlying bug in bsnmpwalk

MFC after:	1 month
PR:		215721
2017-01-04 07:53:01 +00:00
..
gensnmpdef style(9): clean up trailing whitespace 2016-12-27 23:32:54 +00:00
gensnmptree style(9): clean up trailing whitespace 2016-12-27 23:32:54 +00:00
lib Use calloc instead of malloc with buffers in snmp_{recv,send}_packet 2017-01-04 07:53:01 +00:00
snmp_mibII MIB-II: use strlcpy instead of strcpy when copying {descr,name} 2016-12-31 12:03:25 +00:00
snmp_ntp style(9): clean up trailing whitespace 2016-12-27 23:32:54 +00:00
snmp_target style(9): clean up trailing whitespace 2016-12-27 23:32:54 +00:00
snmp_usm style(9): clean up trailing whitespace 2016-12-27 23:32:54 +00:00
snmp_vacm style(9): clean up trailing whitespace 2016-12-27 23:32:54 +00:00
snmpd Initialize msg.msg_flags to 0 2017-01-04 01:38:07 +00:00
FREEBSD-upgrade
FREEBSD-Xlist Don't import tree.h from the distribution - we have our own one in sys. 2006-03-13 09:30:26 +00:00
NEWS Vendor patch: add support for the BITS construct and enumerations in both 2006-05-30 07:46:52 +00:00
oid-list Register OID for HAST module. 2013-05-08 20:04:32 +00:00
README
TODO Virgin import of bsnmpd 1.12 2006-02-27 16:16:18 +00:00
VERSION Virgin import of bsnmpd 1.12 2006-02-27 16:16:18 +00:00

Fri Dec  5 15:01:16 CET 2003

This is a mini-SNMP daemon. The basic daemon implements the system group
and a number of private extensions to manage the UDP transport mapping,
communities, trap destinations and loadable modules. In this form it can
be used to provide remote access to arbitrary data that can be described in
the form as required by the SMI. The daemon speaks both SNMPv1 and SNMPv2c.

One basic loadable module is provided together with the daemon:

- snmp_mibII provides the information groups for ip, tcp, and udp.

Installation
------------

As usual by doing:

	configure [--with-libbegemot[=path]]
	make
	make install

This does not install a configuration file. The standard location for the
configuration is /etc/snmpd.config, but can be overwritten on the command
line. An example configuration file is provided. Use --with-libbegemot
to use libbegemot instead of libisc.

Running
-------

	snmpd [-m name[=value]] [-p pid-file] [-c config-file] [-d] [-l prefix]
	      [-D debug-flags] [-I path]

	-m	defines a configuration macro. If no value is given it
		is set to the empty string.

	-p	specify the file where to store the PID. Default is
		/var/run/{prefix}.pid.

	-c	specify the configuration file. Default is /etc/{prefix}.config.

	-d	don't go into daemon mode.

	-l	specify the prefix. This is used for the default config and
		pid file names and for the syslog. Default is "snmpd".

	-D	specify debug flags:

		d	dump all PDUs.

		e	debug event library.

	-I	specify the include path for system configuration files.
		Default is /etc:/usr/etc:/usr/local/etc.

The directory snmpd contains a snmpd.sh script, which can be copied to
/usr/local/etc/rc.d to automatically start and stop the daemon. snmpd.config
is an example config script.

Bug reports:
-----------

Please report bugs to harti@freebsd.org.

Happy hacking,
harti