901491d025
Extending what the initial revision, r273264, r276985, r277346 have started for the transfer mode and command registers, another pair of 16bit registers written in sequence are block size and block count, which fall together onto the same 32bit line and hence the same register(s) would be written twice in sequence for those as well. Use a similar approach to transfer mode and command and save the writes to either of the block regiters and then only execute a write once. We can do this as with transfer mode their values are meaningless until a command is issued so we can use that write to command as a trigger to also write out the block registers. Compared to transfer mode and command the value of block count can change, so we need to keep state and actually read the block registers back the first time after a write. MFC after: 2 weeks Differential Revision: https://reviews.freebsd.org/D20197 |
||
---|---|---|
.. | ||
bcm2835 |