759 lines
17 KiB
Groff
759 lines
17 KiB
Groff
.\"
|
||
.\" Copyright (c) 2020 Warner Losh <imp@FreeBSD.org>
|
||
.\" Copyright (c) 2018-2019 Alexander Motin <mav@FreeBSD.org>
|
||
.\" Copyright (c) 2012 Intel Corporation
|
||
.\" All rights reserved.
|
||
.\"
|
||
.\" Redistribution and use in source and binary forms, with or without
|
||
.\" modification, are permitted provided that the following conditions
|
||
.\" are met:
|
||
.\" 1. Redistributions of source code must retain the above copyright
|
||
.\" notice, this list of conditions, and the following disclaimer,
|
||
.\" without modification.
|
||
.\" 2. Redistributions in binary form must reproduce at minimum a disclaimer
|
||
.\" substantially similar to the "NO WARRANTY" disclaimer below
|
||
.\" ("Disclaimer") and any redistribution must be conditioned upon
|
||
.\" including a substantially similar Disclaimer requirement for further
|
||
.\" binary redistribution.
|
||
.\"
|
||
.\" NO WARRANTY
|
||
.\" THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
||
.\" "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
||
.\" LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR
|
||
.\" A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
|
||
.\" HOLDERS OR CONTRIBUTORS BE LIABLE FOR SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
||
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
||
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
||
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
|
||
.\" STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING
|
||
.\" IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
||
.\" POSSIBILITY OF SUCH DAMAGES.
|
||
.\"
|
||
.\" nvmecontrol man page.
|
||
.\"
|
||
.\" Author: Jim Harris <jimharris@FreeBSD.org>
|
||
.\"
|
||
.\" $FreeBSD$
|
||
.\"
|
||
.Dd December 14, 2022
|
||
.Dt NVMECONTROL 8
|
||
.Os
|
||
.Sh NAME
|
||
.Nm nvmecontrol
|
||
.Nd NVM Express control utility
|
||
.Sh SYNOPSIS
|
||
.Nm
|
||
.Ic devlist
|
||
.Op Fl h
|
||
.Nm
|
||
.Ic identify
|
||
.Op Fl v
|
||
.Op Fl x
|
||
.Op Fl n Ar nsid
|
||
.Aq Ar device-id | Ar namespace-id
|
||
.Nm
|
||
.Ic perftest
|
||
.Aq Fl n Ar num_threads
|
||
.Aq Fl o Ar read|write
|
||
.Op Fl p
|
||
.Aq Fl s Ar size_in_bytes
|
||
.Aq Fl t Ar time_in_sec
|
||
.Aq Ar namespace-id
|
||
.Nm
|
||
.Ic reset
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic logpage
|
||
.Aq Fl p Ar page_id
|
||
.Op Fl x
|
||
.Op Fl v Ar vendor-string
|
||
.Op Fl b
|
||
.Op Fl f Ar LSP
|
||
.Op Fl i Ar LSI
|
||
.Op Fl r
|
||
.Aq Ar device-id | Ar namespace-id
|
||
.Nm
|
||
.Ic ns active
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns allocated
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns attach
|
||
.Aq Fl n Ar nsid
|
||
.Aq Fl c Ar cntid
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns attached
|
||
.Aq Fl n Ar nsid
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns controllers
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns create
|
||
.Aq Fl s Ar nsze
|
||
.Op Fl c Ar ncap
|
||
.Op Fl f Ar lbaf
|
||
.Op Fl m Ar mset
|
||
.Op Fl n Ar nmic
|
||
.Op Fl p Ar pi
|
||
.Op Fl l Ar pil
|
||
.Op Fl L Ar flbas
|
||
.Op Fl d Ar dps
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns delete
|
||
.Aq Fl n Ar nsid
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns detach
|
||
.Aq Fl n Ar nsid
|
||
.Aq Fl c Ar cntid
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic ns identify
|
||
.Op Fl v
|
||
.Op Fl x
|
||
.Aq Fl n Ar nsid
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic nsid
|
||
.Aq Ar device-id | Ar namespace-id
|
||
.Nm
|
||
.Ic resv acquire
|
||
.Aq Fl c Ar crkey
|
||
.Op Fl p Ar prkey
|
||
.Aq Fl t Ar rtype
|
||
.Aq Fl a Ar racqa
|
||
.Aq Ar namespace-id
|
||
.Nm
|
||
.Ic resv register
|
||
.Op Fl i
|
||
.Op Fl c Ar crkey
|
||
.Aq Fl k Ar nrkey
|
||
.Aq Fl r Ar rrega
|
||
.Op Fl p Ar cptpl
|
||
.Aq Ar namespace-id
|
||
.Nm
|
||
.Ic resv release
|
||
.Aq Fl c Ar crkey
|
||
.Aq Fl t Ar rtype
|
||
.Aq Fl a Ar rrela
|
||
.Aq Ar namespace-id
|
||
.Nm
|
||
.Ic resv report
|
||
.Op Fl e
|
||
.Op Fl v
|
||
.Op Fl x
|
||
.Aq Ar namespace-id
|
||
.Nm
|
||
.Ic firmware
|
||
.Op Fl s Ar slot
|
||
.Op Fl f Ar path_to_firmware
|
||
.Op Fl a
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic format
|
||
.Op Fl f Ar fmt
|
||
.Op Fl m Ar mset
|
||
.Op Fl o Ar pi
|
||
.Op Fl l Ar pil
|
||
.Op Fl E
|
||
.Op Fl C
|
||
.Aq Ar device-id | Ar namespace-id
|
||
.Nm
|
||
.Ic sanitize
|
||
.Aq Fl a Ar sanact
|
||
.Op Fl c Ar owpass
|
||
.Op Fl d
|
||
.Op Fl p Ar ovrpat
|
||
.Op Fl r
|
||
.Op Fl I
|
||
.Op Fl U
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic power
|
||
.Op Fl l
|
||
.Op Fl p power_state
|
||
.Op Fl w workload_hint
|
||
.Nm
|
||
.Ic selftest
|
||
.Aq Fl c Ar code
|
||
.Aq Ar device-id | Ar namespace-id
|
||
.Nm
|
||
.Ic wdc cap-diag
|
||
.Op Fl o path_template
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic wdc drive-log
|
||
.Op Fl o path_template
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic wdc get-crash-dump
|
||
.Op Fl o path_template
|
||
.Aq Ar device-id
|
||
.\" .Nm
|
||
.\" .Ic wdc purge
|
||
.\" .Aq device-id
|
||
.\" .Nm
|
||
.\" .Ic wdc purge-monitor
|
||
.\" .Aq device-id
|
||
.Nm
|
||
.Ic admin-passthru
|
||
.Op args
|
||
.Aq Ar device-id
|
||
.Nm
|
||
.Ic io-passthru
|
||
.Op args
|
||
.Aq Ar namespace-id
|
||
.Sh DESCRIPTION
|
||
NVM Express (NVMe) is a storage protocol standard, for SSDs and other
|
||
high-speed storage devices over PCI Express.
|
||
.Ss devlist
|
||
List all NVMe controllers and namespaces along with their device nodes.
|
||
With the
|
||
.Fl h
|
||
argument, use unit suffixes: Byte, Kibibyte, Mebibyte, Gibibyte, Tebibyte
|
||
and Pebibyte (based on powers of 1024) when showing the disk space.
|
||
By default, uses Mebibyte.
|
||
.Ss identify
|
||
The identify commands reports information from the drive's
|
||
.Dv IDENTIFY_CONTROLLER
|
||
if a
|
||
.Ar device-id
|
||
is specified.
|
||
It reports
|
||
.Dv IDENTIFY_NAMESPACE
|
||
data if a
|
||
.Ar namespace-id
|
||
is specified.
|
||
When used with disk names, the
|
||
.Dv IDENTIFY_NAMESPACE
|
||
data is reported, unless the namespace
|
||
.Ar nsid
|
||
is overridden with the
|
||
.Fl n
|
||
flag.
|
||
Then that namespace's data is reported, if it exists.
|
||
The command accepts the following parameters:
|
||
.Bl -tag -width 6n
|
||
.It Fl n
|
||
The namespace
|
||
.Aq nsid
|
||
to use instead of the namespace associated with the device.
|
||
A
|
||
.Ar nsid
|
||
of
|
||
.Dq 0
|
||
is used to retrieve the
|
||
.Dv IDENTIFY_CONTROLLER
|
||
data associated with that drive.
|
||
.El
|
||
.Ss logpage
|
||
The logpage command knows how to print log pages of various types.
|
||
It also knows about vendor specific log pages from hgst/wdc, samsung and intel.
|
||
Note that some vendors use the same log page numbers for different data.
|
||
.Pp
|
||
.Bl -tag -compact -width "Page 0x00"
|
||
.It Dv Page 0x01
|
||
Drive Error Log
|
||
.It Dv Page 0x02
|
||
Health/SMART Data
|
||
.It Dv Page 0x03
|
||
Firmware Information
|
||
.It Dv Page 0x04
|
||
Changed Namespace List
|
||
.It Dv Page 0x05
|
||
Commands Supported and Effects
|
||
.It Dv Page 0x06
|
||
Device Self-test
|
||
.It Dv Page 0x80
|
||
Reservation Notification
|
||
.It Dv Page 0x81
|
||
Sanitize Status
|
||
.It Dv Page 0xc1
|
||
Advanced SMART information (WDC/HGST)
|
||
.It Dv Page 0xc1
|
||
Read latency stats (Intel)
|
||
.It Dv Page 0xc2
|
||
Wite latency stats (Intel)
|
||
.It Dv Page 0xc5
|
||
Temperature stats (Intel)
|
||
.It Dv Page 0xca
|
||
Advanced SMART information (Intel)
|
||
.It Dv Page 0xca
|
||
Extended SMART information (Samsung)
|
||
.El
|
||
.Pp
|
||
Specifying
|
||
.Fl v
|
||
.Ic help
|
||
will list all valid vendors and pages.
|
||
.Fl x
|
||
will print the page as hex.
|
||
.Fl b
|
||
will print the binary data for the page.
|
||
.Fl s
|
||
will set Log Specific Field.
|
||
.Fl i
|
||
will set Log Specific Identifier.
|
||
.Fl r
|
||
will set Retain Asynchronous Event.
|
||
.Ss ns
|
||
Various namespace management commands.
|
||
If namespace management is supported by device, allow list, create and delete
|
||
namespaces, list, attach and detach controllers to namespaces.
|
||
.Ss nsid
|
||
Reports the namespace id and controller device associated with the
|
||
.Aq Ar namespace-id
|
||
or
|
||
.Aq Ar device-id
|
||
argument.
|
||
.Ss resv acquire
|
||
Acquire or preempt namespace reservation, using specified parameters:
|
||
.Bl -tag -width 6n
|
||
.It Fl a
|
||
Acquire action:
|
||
.Bl -tag -compact -width 6n
|
||
.It Dv 0
|
||
Acquire
|
||
.It Dv 1
|
||
Preempt
|
||
.It Dv 2
|
||
Preempt and abort
|
||
.El
|
||
.It Fl c
|
||
Current reservation key.
|
||
.It Fl p
|
||
Preempt reservation key.
|
||
.It Fl t
|
||
Reservation type:
|
||
.Bl -tag -compact -width 6n
|
||
.It Dv 1
|
||
Write Exclusive
|
||
.It Dv 2
|
||
Exclusive Access
|
||
.It Dv 3
|
||
Write Exclusive - Registrants Only
|
||
.It Dv 4
|
||
Exclusive Access - Registrants Only
|
||
.It Dv 5
|
||
Write Exclusive - All Registrants
|
||
.It Dv 6
|
||
Exclusive Access - All Registrants
|
||
.El
|
||
.El
|
||
.Ss resv register
|
||
Register, unregister or replace reservation key, using specified parameters:
|
||
.Bl -tag -width 6n
|
||
.It Fl c
|
||
Current reservation key.
|
||
.It Fl k
|
||
New reservation key.
|
||
.It Fl r
|
||
Register action:
|
||
.Bl -tag -compact -width 6n
|
||
.It Dv 0
|
||
Register
|
||
.It Dv 1
|
||
Unregister
|
||
.It Dv 2
|
||
Replace
|
||
.El
|
||
.It Fl i
|
||
Ignore Existing Key
|
||
.It Fl p
|
||
Change Persist Through Power Loss State:
|
||
.Bl -tag -compact -width 6n
|
||
.It Dv 0
|
||
No change to PTPL state
|
||
.It Dv 2
|
||
Set PTPL state to ‘0’.
|
||
Reservations are released and registrants are cleared on a power on.
|
||
.It Dv 3
|
||
Set PTPL state to ‘1’.
|
||
Reservations and registrants persist across a power loss.
|
||
.El
|
||
.El
|
||
.Ss resv release
|
||
Release or clear reservation, using specified parameters:
|
||
.Bl -tag -width 6n
|
||
.It Fl c
|
||
Current reservation key.
|
||
.It Fl t
|
||
Reservation type.
|
||
.It Fl a
|
||
Release action:
|
||
.Bl -tag -compact -width 6n
|
||
.It Dv 0
|
||
Release
|
||
.It Dv 1
|
||
Clean
|
||
.El
|
||
.El
|
||
.Ss resv report
|
||
Print reservation status, using specified parameters:
|
||
.Bl -tag -width 6n
|
||
.It Fl x
|
||
Print reservation status in hex.
|
||
.It Fl e
|
||
Use Extended Data Structure.
|
||
.El
|
||
.Ss format
|
||
Format either specified namespace, or all namespaces of specified controller,
|
||
using specified parameters:
|
||
.Ar fmt
|
||
LBA Format,
|
||
.Ar mset
|
||
Metadata Settings,
|
||
.Ar pi
|
||
Protection Information,
|
||
.Ar pil
|
||
Protection Information Location.
|
||
When formatting specific namespace, existing values are used as defaults.
|
||
When formatting all namespaces, all parameters should be specified.
|
||
Some controllers may not support formatting or erasing specific or all
|
||
namespaces.
|
||
Option
|
||
.Fl E
|
||
enables User Data Erase during format.
|
||
Option
|
||
.Fl C
|
||
enables Cryptographic Erase during format.
|
||
.Ss sanitize
|
||
Sanitize NVM subsystem of specified controller,
|
||
using specified parameters:
|
||
.Bl -tag -width 6n
|
||
.It Fl a Ar operation
|
||
Specify the sanitize operation to perform.
|
||
.Bl -tag -width 16n
|
||
.It overwrite
|
||
Perform an overwrite operation by writing a user supplied
|
||
data pattern to the device one or more times.
|
||
The pattern is given by the
|
||
.Fl p
|
||
argument.
|
||
The number of times is given by the
|
||
.Fl c
|
||
argument.
|
||
.It block
|
||
Perform a block erase operation.
|
||
All the device's blocks are set to a vendor defined
|
||
value, typically zero.
|
||
.It crypto
|
||
Perform a cryptographic erase operation.
|
||
The encryption keys are changed to prevent the decryption
|
||
of the data.
|
||
.It exitfailure
|
||
Exits a previously failed sanitize operation.
|
||
A failed sanitize operation can only be exited if it was
|
||
run in the unrestricted completion mode, as provided by the
|
||
.Fl U
|
||
argument.
|
||
.El
|
||
.It Fl c Ar passes
|
||
The number of passes when performing an
|
||
.Sq overwrite
|
||
operation.
|
||
Valid values are between 1 and 16.
|
||
The default is 1.
|
||
.It Fl d
|
||
No Deallocate After Sanitize.
|
||
.It Fl I
|
||
When performing an
|
||
.Sq overwrite
|
||
operation, the pattern is inverted between consecutive passes.
|
||
.It Fl p Ar pattern
|
||
32 bits of pattern to use when performing an
|
||
.Sq overwrite
|
||
operation.
|
||
The pattern is repeated as needed to fill each block.
|
||
.It Fl U
|
||
Perform the sanitize in the unrestricted completion mode.
|
||
If the operation fails, it can later be exited with the
|
||
.Sq exitfailure
|
||
operation.
|
||
.It Fl r
|
||
Run in
|
||
.Dq report only
|
||
mode.
|
||
This will report status on a sanitize that is already running on the drive.
|
||
.El
|
||
.Ss power
|
||
Manage the power modes of the NVMe controller.
|
||
.Bl -tag -width 6n
|
||
.It Fl l
|
||
List all supported power modes.
|
||
.It Fl p Ar mode
|
||
Set the power mode to
|
||
.Ar mode .
|
||
This must be a mode listed with the
|
||
.Dl nvmecontrol power -l
|
||
command.
|
||
.It Fl w Ar hint
|
||
Set the workload hint for automatic power mode control.
|
||
.Bl -tag -compact -width 6n
|
||
.It 0
|
||
No workload hint is provided.
|
||
.It 1
|
||
Extended idle period workload.
|
||
The device is often idle for minutes at a time.
|
||
A burst of write commands comes in over a period of seconds.
|
||
Then the device returns to being idle.
|
||
.It 2
|
||
Heavy sequential writes.
|
||
A huge number of sequential writes will be submitted, filling the submission queues.
|
||
.It Other
|
||
All other values are reserved and have no standard meaning.
|
||
.El
|
||
Please see the
|
||
.Dq NVM Subsystem Workloads
|
||
section of the relevant NVM Express Base Standard for details.
|
||
.El
|
||
.Ss selftest
|
||
Start the specified device self-test:
|
||
.Bl -tag -width 6n
|
||
.It Fl c Ar code
|
||
Specify the device self-test command code.
|
||
Common codes are:
|
||
.Bl -tag -compact -width 6n
|
||
.It Dv 0x1
|
||
Start a short device self-test operation
|
||
.It Dv 0x2
|
||
Start an extended device self-test operation
|
||
.It Dv 0xe
|
||
Start a vendor specific device self-test operation
|
||
.It Dv 0xf
|
||
Abort the device self-test operation
|
||
.El
|
||
.El
|
||
.Ss wdc
|
||
The various wdc command retrieve log data from the wdc/hgst drives.
|
||
The
|
||
.Fl o
|
||
flag specifies a path template to use to output the files.
|
||
Each file takes the path template (which defaults to nothing), appends
|
||
the drive's serial number and the type of dump it is followed
|
||
by .bin.
|
||
These logs must be sent to the vendor for analysis.
|
||
This tool only provides a way to extract them.
|
||
.Ss passthru
|
||
The
|
||
.Dq admin-passthru
|
||
and
|
||
.Dq io-passthru
|
||
commands send NVMe commands to
|
||
either the administrative or the data part of the device.
|
||
These commands are expected to be compatible with nvme-cli.
|
||
Please see the NVM Express Base Standard for details.
|
||
.Bl -tag -width 16n
|
||
.It Fl o -opcode Ar opcode
|
||
Opcode to send.
|
||
.It Fl 2 -cdw2 Ar value
|
||
32-bit value for CDW2.
|
||
.It Fl 3 -cdw3 Ar value
|
||
32-bit value for CDW3.
|
||
.It Fl 4 -cdw10 Ar value
|
||
32-bit value for CDW10.
|
||
.It Fl 5 -cdw11 Ar value
|
||
32-bit value for CDW11.
|
||
.It Fl 6 -cdw12 Ar value
|
||
32-bit value for CDW12.
|
||
.It Fl 7 -cdw13 Ar value
|
||
32-bit value for CDW13.
|
||
.It Fl 8 -cdw14 Ar value
|
||
32-bit value for CDW14.
|
||
.It Fl 9 -cdw15 Ar value
|
||
32-bit value for CDW15.
|
||
.It Fl l -data-len
|
||
Length of the data for I/O (bytes).
|
||
.It Fl m -metadata-len
|
||
Length of the metadata segment for command (bytes).
|
||
This is ignored and not implemented in
|
||
.Xr nvme 4 .
|
||
.It Fl f -flags
|
||
Nvme command flags.
|
||
.It Fl n -namespace-id
|
||
Namespace ID for command (Ignored).
|
||
.It Fl p -prefill
|
||
Value to prefill payload with.
|
||
.It Fl b -raw-binary
|
||
Output in binary format (otherwise a hex dump is produced).
|
||
.It Fl d -dry-run
|
||
Do not actually execute the command, but perform sanity checks on it.
|
||
.It Fl r -read
|
||
Command reads data from the device.
|
||
.It Fl s -show-command
|
||
Show all the command values on stdout.
|
||
.It Fl w -write
|
||
Command writes data to the device.
|
||
.El
|
||
.Pp
|
||
Send arbitrary commands to the device.
|
||
Can be used to extract vendor specific logs.
|
||
Transfers to/from the device possible, but limited to
|
||
.Dv MAXPHYS
|
||
bytes.
|
||
Commands either read data or write it, but not both.
|
||
Commands needing metadata are not supported by the
|
||
.Xr nvme 4
|
||
drive.
|
||
.Sh DEVICE NAMES
|
||
Where
|
||
.Aq Ar namespace-id
|
||
is required, you can use either the
|
||
.Pa nvmeXnsY
|
||
device, or the disk device such as
|
||
.Pa ndaZ
|
||
or
|
||
.Pa nvdZ .
|
||
The leading
|
||
.Pa /dev/
|
||
is omitted.
|
||
Where
|
||
.Aq Ar device-id
|
||
is required, you can use either the
|
||
.Pa nvmeX
|
||
device, or the disk device such as
|
||
.Pa ndaZ
|
||
or
|
||
.Pa nvdZ .
|
||
For commands that take an optional
|
||
.Aq nsid
|
||
you can use it to get information on other namespaces, or to query the
|
||
drive itself.
|
||
A
|
||
.Aq nsid
|
||
of
|
||
.Dq 0
|
||
means query the drive itself.
|
||
.Sh EXAMPLES
|
||
.Dl nvmecontrol devlist
|
||
.Pp
|
||
Display a list of NVMe controllers and namespaces along with their device nodes.
|
||
.Pp
|
||
.Dl nvmecontrol identify nvme0
|
||
.Dl nvmecontrol identify -n 0 nvd0
|
||
.Pp
|
||
Display a human-readable summary of the nvme0
|
||
.Dv IDENTIFY_CONTROLLER
|
||
data.
|
||
In this example, nvd0 is connected to nvme0.
|
||
.Pp
|
||
.Dl nvmecontrol identify -x -v nvme0ns1
|
||
.Dl nvmecontrol identify -x -v -n 1 nvme0
|
||
.Pp
|
||
Display an hexadecimal dump of the nvme0
|
||
.Dv IDENTIFY_NAMESPACE
|
||
data for namespace 1.
|
||
.Pp
|
||
.Dl nvmecontrol perftest -n 32 -o read -s 512 -t 30 nvme0ns1
|
||
.Pp
|
||
Run a performance test on nvme0ns1 using 32 kernel threads for 30 seconds.
|
||
Each thread will issue a single 512 byte read command.
|
||
Results are printed to stdout when 30 seconds expires.
|
||
.Pp
|
||
.Dl nvmecontrol reset nvme0
|
||
.Dl nvmecontrol reset nda4
|
||
.Pp
|
||
Perform a controller-level reset of the nvme0 controller.
|
||
In this example, nda4 is wired to nvme0.
|
||
.Pp
|
||
.Dl nvmecontrol logpage -p 1 nvme0
|
||
.Pp
|
||
Display a human-readable summary of the nvme0 controller's Error Information Log.
|
||
Log pages defined by the NVMe specification include Error Information Log (ID=1),
|
||
SMART/Health Information Log (ID=2), and Firmware Slot Log (ID=3).
|
||
.Pp
|
||
.Dl nvmecontrol logpage -p 0xc1 -v wdc nvme0
|
||
.Pp
|
||
Display a human-readable summary of the nvme0's wdc-specific advanced
|
||
SMART data.
|
||
.Pp
|
||
.Dl nvmecontrol logpage -p 1 -x nvme0
|
||
.Pp
|
||
Display a hexadecimal dump of the nvme0 controller's Error Information Log.
|
||
.Pp
|
||
.Dl nvmecontrol logpage -p 0xcb -b nvme0 > /tmp/page-cb.bin
|
||
.Pp
|
||
Print the contents of vendor specific page 0xcb as binary data on
|
||
standard out.
|
||
Redirect it to a temporary file.
|
||
.Pp
|
||
.Dl nvmecontrol firmware -s 2 -f /tmp/nvme_firmware nvme0
|
||
.Pp
|
||
Download the firmware image contained in "/tmp/nvme_firmware" to slot 2 of the
|
||
nvme0 controller, but do not activate the image.
|
||
.Pp
|
||
.Dl nvmecontrol firmware -s 4 -a nvme0
|
||
.Pp
|
||
Activate the firmware in slot 4 of the nvme0 controller on the next reset.
|
||
.Pp
|
||
.Dl nvmecontrol firmware -s 7 -f /tmp/nvme_firmware -a nvme0
|
||
.Pp
|
||
Download the firmware image contained in "/tmp/nvme_firmware" to slot 7 of the
|
||
nvme0 controller and activate it on the next reset.
|
||
.Pp
|
||
.Dl nvmecontrol power -l nvme0
|
||
.Pp
|
||
List all the current power modes.
|
||
.Pp
|
||
.Dl nvmecontrol power -p 3 nvme0
|
||
.Pp
|
||
Set the current power mode.
|
||
.Pp
|
||
.Dl nvmecontrol power nvme0
|
||
.Pp
|
||
Get the current power mode.
|
||
.Pp
|
||
.Dl nvmecontrol identify -n 0 nda0
|
||
.Pp
|
||
Identify the drive data associated with the
|
||
.Pa nda0
|
||
device.
|
||
The corresponding
|
||
.Pa nvmeX
|
||
devices is used automatically.
|
||
.Pp
|
||
.Dl nvmecontrol identify nda0
|
||
.Pp
|
||
Get the namespace parameters associated with the
|
||
.Pa nda0
|
||
device.
|
||
The corresponding
|
||
.Pa nvmeXnsY
|
||
device is used automatically.
|
||
.Sh DYNAMIC LOADING
|
||
The directories
|
||
.Pa /lib/nvmecontrol
|
||
and
|
||
.Pa /usr/local/lib/nvmecontrol
|
||
are scanned for any .so files.
|
||
These files are loaded.
|
||
The members of the
|
||
.Va top
|
||
linker set are added to the top-level commands.
|
||
The members of the
|
||
.Va logpage
|
||
linker set are added to the logpage parsers.
|
||
.Sh SEE ALSO
|
||
.Rs
|
||
.%T The NVM Express Base Specification
|
||
.%D June 10, 2019
|
||
.%U https://nvmexpress.org/wp-content/uploads/NVM-Express-1_4-2019.06.10-Ratified.pdf
|
||
.Re
|
||
.Sh HISTORY
|
||
The
|
||
.Nm
|
||
utility appeared in
|
||
.Fx 9.2 .
|
||
.Sh AUTHORS
|
||
.An -nosplit
|
||
.Nm
|
||
was developed by Intel and originally written by
|
||
.An Jim Harris Aq Mt jimharris@FreeBSD.org .
|
||
.Pp
|
||
This man page was written by
|
||
.An Jim Harris Aq Mt jimharris@FreeBSD.org .
|