Make sure not to start I/O bigger than MAXPHYS bytes. Quoting r264504: When we detect the condition, we'll reduce the block count and perform a "short" read. In g_uncompress_done() we need to consider the original I/O length and stop early if we're about to deflate a block that we didn't read. By using bio_completed in the cloned BIO and not bio_length to check for this, we automatically and gracefully handle short reads that our providers may be doing on top of the short reads we may initiate ourselves. Reviewed by: marcel |
||
---|---|---|
.. | ||