339 lines
15 KiB
HTML
339 lines
15 KiB
HTML
<!--
|
||
- Copyright (C) 2004-2012 Internet Systems Consortium, Inc. ("ISC")
|
||
- Copyright (C) 2000-2003 Internet Software Consortium.
|
||
-
|
||
- Permission to use, copy, modify, and/or distribute this software for any
|
||
- purpose with or without fee is hereby granted, provided that the above
|
||
- copyright notice and this permission notice appear in all copies.
|
||
-
|
||
- THE SOFTWARE IS PROVIDED "AS IS" AND ISC DISCLAIMS ALL WARRANTIES WITH
|
||
- REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY
|
||
- AND FITNESS. IN NO EVENT SHALL ISC BE LIABLE FOR ANY SPECIAL, DIRECT,
|
||
- INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM
|
||
- LOSS OF USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE
|
||
- OR OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
|
||
- PERFORMANCE OF THIS SOFTWARE.
|
||
-->
|
||
<!-- $Id$ -->
|
||
<html>
|
||
<head>
|
||
<meta http-equiv="Content-Type" content="text/html; charset=ISO-8859-1">
|
||
<title>named</title>
|
||
<meta name="generator" content="DocBook XSL Stylesheets V1.71.1">
|
||
<link rel="start" href="Bv9ARM.html" title="BIND 9 Administrator Reference Manual">
|
||
<link rel="up" href="Bv9ARM.ch10.html" title="Manual pages">
|
||
<link rel="prev" href="man.named-checkzone.html" title="named-checkzone">
|
||
<link rel="next" href="man.named-journalprint.html" title="named-journalprint">
|
||
</head>
|
||
<body bgcolor="white" text="black" link="#0000FF" vlink="#840084" alink="#0000FF">
|
||
<div class="navheader">
|
||
<table width="100%" summary="Navigation header">
|
||
<tr><th colspan="3" align="center"><span class="application">named</span></th></tr>
|
||
<tr>
|
||
<td width="20%" align="left">
|
||
<a accesskey="p" href="man.named-checkzone.html">Prev</a> </td>
|
||
<th width="60%" align="center">Manual pages</th>
|
||
<td width="20%" align="right"> <a accesskey="n" href="man.named-journalprint.html">Next</a>
|
||
</td>
|
||
</tr>
|
||
</table>
|
||
<hr>
|
||
</div>
|
||
<div class="refentry" lang="en">
|
||
<a name="man.named"></a><div class="titlepage"></div>
|
||
<div class="refnamediv">
|
||
<h2>Name</h2>
|
||
<p><span class="application">named</span> — Internet domain name server</p>
|
||
</div>
|
||
<div class="refsynopsisdiv">
|
||
<h2>Synopsis</h2>
|
||
<div class="cmdsynopsis"><p><code class="command">named</code> [<code class="option">-4</code>] [<code class="option">-6</code>] [<code class="option">-c <em class="replaceable"><code>config-file</code></em></code>] [<code class="option">-d <em class="replaceable"><code>debug-level</code></em></code>] [<code class="option">-E <em class="replaceable"><code>engine-name</code></em></code>] [<code class="option">-f</code>] [<code class="option">-g</code>] [<code class="option">-m <em class="replaceable"><code>flag</code></em></code>] [<code class="option">-n <em class="replaceable"><code>#cpus</code></em></code>] [<code class="option">-p <em class="replaceable"><code>port</code></em></code>] [<code class="option">-s</code>] [<code class="option">-S <em class="replaceable"><code>#max-socks</code></em></code>] [<code class="option">-t <em class="replaceable"><code>directory</code></em></code>] [<code class="option">-u <em class="replaceable"><code>user</code></em></code>] [<code class="option">-v</code>] [<code class="option">-V</code>] [<code class="option">-x <em class="replaceable"><code>cache-file</code></em></code>]</p></div>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2635533"></a><h2>DESCRIPTION</h2>
|
||
<p><span><strong class="command">named</strong></span>
|
||
is a Domain Name System (DNS) server,
|
||
part of the BIND 9 distribution from ISC. For more
|
||
information on the DNS, see RFCs 1033, 1034, and 1035.
|
||
</p>
|
||
<p>
|
||
When invoked without arguments, <span><strong class="command">named</strong></span>
|
||
will
|
||
read the default configuration file
|
||
<code class="filename">/etc/named.conf</code>, read any initial
|
||
data, and listen for queries.
|
||
</p>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2635564"></a><h2>OPTIONS</h2>
|
||
<div class="variablelist"><dl>
|
||
<dt><span class="term">-4</span></dt>
|
||
<dd><p>
|
||
Use IPv4 only even if the host machine is capable of IPv6.
|
||
<code class="option">-4</code> and <code class="option">-6</code> are mutually
|
||
exclusive.
|
||
</p></dd>
|
||
<dt><span class="term">-6</span></dt>
|
||
<dd><p>
|
||
Use IPv6 only even if the host machine is capable of IPv4.
|
||
<code class="option">-4</code> and <code class="option">-6</code> are mutually
|
||
exclusive.
|
||
</p></dd>
|
||
<dt><span class="term">-c <em class="replaceable"><code>config-file</code></em></span></dt>
|
||
<dd><p>
|
||
Use <em class="replaceable"><code>config-file</code></em> as the
|
||
configuration file instead of the default,
|
||
<code class="filename">/etc/named.conf</code>. To
|
||
ensure that reloading the configuration file continues
|
||
to work after the server has changed its working
|
||
directory due to to a possible
|
||
<code class="option">directory</code> option in the configuration
|
||
file, <em class="replaceable"><code>config-file</code></em> should be
|
||
an absolute pathname.
|
||
</p></dd>
|
||
<dt><span class="term">-d <em class="replaceable"><code>debug-level</code></em></span></dt>
|
||
<dd><p>
|
||
Set the daemon's debug level to <em class="replaceable"><code>debug-level</code></em>.
|
||
Debugging traces from <span><strong class="command">named</strong></span> become
|
||
more verbose as the debug level increases.
|
||
</p></dd>
|
||
<dt><span class="term">-E <em class="replaceable"><code>engine-name</code></em></span></dt>
|
||
<dd><p>
|
||
Use a crypto hardware (OpenSSL engine) for the crypto operations
|
||
it supports, for instance re-signing with private keys from
|
||
a secure key store. When compiled with PKCS#11 support
|
||
<em class="replaceable"><code>engine-name</code></em>
|
||
defaults to pkcs11, the empty name resets it to no engine.
|
||
</p></dd>
|
||
<dt><span class="term">-f</span></dt>
|
||
<dd><p>
|
||
Run the server in the foreground (i.e. do not daemonize).
|
||
</p></dd>
|
||
<dt><span class="term">-g</span></dt>
|
||
<dd><p>
|
||
Run the server in the foreground and force all logging
|
||
to <code class="filename">stderr</code>.
|
||
</p></dd>
|
||
<dt><span class="term">-m <em class="replaceable"><code>flag</code></em></span></dt>
|
||
<dd><p>
|
||
Turn on memory usage debugging flags. Possible flags are
|
||
<em class="replaceable"><code>usage</code></em>,
|
||
<em class="replaceable"><code>trace</code></em>,
|
||
<em class="replaceable"><code>record</code></em>,
|
||
<em class="replaceable"><code>size</code></em>, and
|
||
<em class="replaceable"><code>mctx</code></em>.
|
||
These correspond to the ISC_MEM_DEBUGXXXX flags described in
|
||
<code class="filename"><isc/mem.h></code>.
|
||
</p></dd>
|
||
<dt><span class="term">-n <em class="replaceable"><code>#cpus</code></em></span></dt>
|
||
<dd><p>
|
||
Create <em class="replaceable"><code>#cpus</code></em> worker threads
|
||
to take advantage of multiple CPUs. If not specified,
|
||
<span><strong class="command">named</strong></span> will try to determine the
|
||
number of CPUs present and create one thread per CPU.
|
||
If it is unable to determine the number of CPUs, a
|
||
single worker thread will be created.
|
||
</p></dd>
|
||
<dt><span class="term">-p <em class="replaceable"><code>port</code></em></span></dt>
|
||
<dd><p>
|
||
Listen for queries on port <em class="replaceable"><code>port</code></em>. If not
|
||
specified, the default is port 53.
|
||
</p></dd>
|
||
<dt><span class="term">-s</span></dt>
|
||
<dd>
|
||
<p>
|
||
Write memory usage statistics to <code class="filename">stdout</code> on exit.
|
||
</p>
|
||
<div class="note" style="margin-left: 0.5in; margin-right: 0.5in;">
|
||
<h3 class="title">Note</h3>
|
||
<p>
|
||
This option is mainly of interest to BIND 9 developers
|
||
and may be removed or changed in a future release.
|
||
</p>
|
||
</div>
|
||
</dd>
|
||
<dt><span class="term">-S <em class="replaceable"><code>#max-socks</code></em></span></dt>
|
||
<dd>
|
||
<p>
|
||
Allow <span><strong class="command">named</strong></span> to use up to
|
||
<em class="replaceable"><code>#max-socks</code></em> sockets.
|
||
</p>
|
||
<div class="warning" style="margin-left: 0.5in; margin-right: 0.5in;">
|
||
<h3 class="title">Warning</h3>
|
||
<p>
|
||
This option should be unnecessary for the vast majority
|
||
of users.
|
||
The use of this option could even be harmful because the
|
||
specified value may exceed the limitation of the
|
||
underlying system API.
|
||
It is therefore set only when the default configuration
|
||
causes exhaustion of file descriptors and the
|
||
operational environment is known to support the
|
||
specified number of sockets.
|
||
Note also that the actual maximum number is normally a little
|
||
fewer than the specified value because
|
||
<span><strong class="command">named</strong></span> reserves some file descriptors
|
||
for its internal use.
|
||
</p>
|
||
</div>
|
||
</dd>
|
||
<dt><span class="term">-t <em class="replaceable"><code>directory</code></em></span></dt>
|
||
<dd>
|
||
<p>Chroot
|
||
to <em class="replaceable"><code>directory</code></em> after
|
||
processing the command line arguments, but before
|
||
reading the configuration file.
|
||
</p>
|
||
<div class="warning" style="margin-left: 0.5in; margin-right: 0.5in;">
|
||
<h3 class="title">Warning</h3>
|
||
<p>
|
||
This option should be used in conjunction with the
|
||
<code class="option">-u</code> option, as chrooting a process
|
||
running as root doesn't enhance security on most
|
||
systems; the way <code class="function">chroot(2)</code> is
|
||
defined allows a process with root privileges to
|
||
escape a chroot jail.
|
||
</p>
|
||
</div>
|
||
</dd>
|
||
<dt><span class="term">-u <em class="replaceable"><code>user</code></em></span></dt>
|
||
<dd>
|
||
<p>Setuid
|
||
to <em class="replaceable"><code>user</code></em> after completing
|
||
privileged operations, such as creating sockets that
|
||
listen on privileged ports.
|
||
</p>
|
||
<div class="note" style="margin-left: 0.5in; margin-right: 0.5in;">
|
||
<h3 class="title">Note</h3>
|
||
<p>
|
||
On Linux, <span><strong class="command">named</strong></span> uses the kernel's
|
||
capability mechanism to drop all root privileges
|
||
except the ability to <code class="function">bind(2)</code> to
|
||
a
|
||
privileged port and set process resource limits.
|
||
Unfortunately, this means that the <code class="option">-u</code>
|
||
option only works when <span><strong class="command">named</strong></span> is
|
||
run
|
||
on kernel 2.2.18 or later, or kernel 2.3.99-pre3 or
|
||
later, since previous kernels did not allow privileges
|
||
to be retained after <code class="function">setuid(2)</code>.
|
||
</p>
|
||
</div>
|
||
</dd>
|
||
<dt><span class="term">-v</span></dt>
|
||
<dd><p>
|
||
Report the version number and exit.
|
||
</p></dd>
|
||
<dt><span class="term">-V</span></dt>
|
||
<dd><p>
|
||
Report the version number and build options, and exit.
|
||
</p></dd>
|
||
<dt><span class="term">-x <em class="replaceable"><code>cache-file</code></em></span></dt>
|
||
<dd>
|
||
<p>
|
||
Load data from <em class="replaceable"><code>cache-file</code></em> into the
|
||
cache of the default view.
|
||
</p>
|
||
<div class="warning" style="margin-left: 0.5in; margin-right: 0.5in;">
|
||
<h3 class="title">Warning</h3>
|
||
<p>
|
||
This option must not be used. It is only of interest
|
||
to BIND 9 developers and may be removed or changed in a
|
||
future release.
|
||
</p>
|
||
</div>
|
||
</dd>
|
||
</dl></div>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2660284"></a><h2>SIGNALS</h2>
|
||
<p>
|
||
In routine operation, signals should not be used to control
|
||
the nameserver; <span><strong class="command">rndc</strong></span> should be used
|
||
instead.
|
||
</p>
|
||
<div class="variablelist"><dl>
|
||
<dt><span class="term">SIGHUP</span></dt>
|
||
<dd><p>
|
||
Force a reload of the server.
|
||
</p></dd>
|
||
<dt><span class="term">SIGINT, SIGTERM</span></dt>
|
||
<dd><p>
|
||
Shut down the server.
|
||
</p></dd>
|
||
</dl></div>
|
||
<p>
|
||
The result of sending any other signals to the server is undefined.
|
||
</p>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2660334"></a><h2>CONFIGURATION</h2>
|
||
<p>
|
||
The <span><strong class="command">named</strong></span> configuration file is too complex
|
||
to describe in detail here. A complete description is provided
|
||
in the
|
||
<em class="citetitle">BIND 9 Administrator Reference Manual</em>.
|
||
</p>
|
||
<p>
|
||
<span><strong class="command">named</strong></span> inherits the <code class="function">umask</code>
|
||
(file creation mode mask) from the parent process. If files
|
||
created by <span><strong class="command">named</strong></span>, such as journal files,
|
||
need to have custom permissions, the <code class="function">umask</code>
|
||
should be set explicitly in the script used to start the
|
||
<span><strong class="command">named</strong></span> process.
|
||
</p>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2660384"></a><h2>FILES</h2>
|
||
<div class="variablelist"><dl>
|
||
<dt><span class="term"><code class="filename">/etc/named.conf</code></span></dt>
|
||
<dd><p>
|
||
The default configuration file.
|
||
</p></dd>
|
||
<dt><span class="term"><code class="filename">/var/run/named/named.pid</code></span></dt>
|
||
<dd><p>
|
||
The default process-id file.
|
||
</p></dd>
|
||
</dl></div>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2660427"></a><h2>SEE ALSO</h2>
|
||
<p><em class="citetitle">RFC 1033</em>,
|
||
<em class="citetitle">RFC 1034</em>,
|
||
<em class="citetitle">RFC 1035</em>,
|
||
<span class="citerefentry"><span class="refentrytitle">named-checkconf</span>(8)</span>,
|
||
<span class="citerefentry"><span class="refentrytitle">named-checkzone</span>(8)</span>,
|
||
<span class="citerefentry"><span class="refentrytitle">rndc</span>(8)</span>,
|
||
<span class="citerefentry"><span class="refentrytitle">lwresd</span>(8)</span>,
|
||
<span class="citerefentry"><span class="refentrytitle">named.conf</span>(5)</span>,
|
||
<em class="citetitle">BIND 9 Administrator Reference Manual</em>.
|
||
</p>
|
||
</div>
|
||
<div class="refsect1" lang="en">
|
||
<a name="id2675585"></a><h2>AUTHOR</h2>
|
||
<p><span class="corpauthor">Internet Systems Consortium</span>
|
||
</p>
|
||
</div>
|
||
</div>
|
||
<div class="navfooter">
|
||
<hr>
|
||
<table width="100%" summary="Navigation footer">
|
||
<tr>
|
||
<td width="40%" align="left">
|
||
<a accesskey="p" href="man.named-checkzone.html">Prev</a> </td>
|
||
<td width="20%" align="center"><a accesskey="u" href="Bv9ARM.ch10.html">Up</a></td>
|
||
<td width="40%" align="right"> <a accesskey="n" href="man.named-journalprint.html">Next</a>
|
||
</td>
|
||
</tr>
|
||
<tr>
|
||
<td width="40%" align="left" valign="top">
|
||
<span class="application">named-checkzone</span> </td>
|
||
<td width="20%" align="center"><a accesskey="h" href="Bv9ARM.html">Home</a></td>
|
||
<td width="40%" align="right" valign="top"> <span class="application">named-journalprint</span>
|
||
</td>
|
||
</tr>
|
||
</table>
|
||
</div>
|
||
</body>
|
||
</html>
|