freebsd-dev/sys/arm/include/physmem.h
Pedro F. Giffuni af3dc4a7ca sys/arm: further adoption of SPDX licensing ID tags.
Mainly focus on files that use BSD 2-Clause license, however the tool I
was using misidentified many licenses so this was mostly a manual - error
prone - task.

The Software Package Data Exchange (SPDX) group provides a specification
to make it easier for automated tools to detect and summarize well known
opensource licenses. We are gradually adopting the specification, noting
that the tags are considered only advisory and do not, in any way,
superceed or replace the license texts.
2017-11-27 15:04:10 +00:00

94 lines
3.0 KiB
C

/*-
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
*
* Copyright (c) 2014 Ian Lepore <ian@freebsd.org>
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* 2. Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in the
* documentation and/or other materials provided with the distribution.
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* $FreeBSD$
*/
#ifndef _MACHINE_PHYSMEM_H_
#define _MACHINE_PHYSMEM_H_
/*
* The physical address at which the kernel was loaded.
*/
extern vm_paddr_t arm_physmem_kernaddr;
/*
* Routines to help configure physical ram.
*
* Multiple regions of contiguous physical ram can be added (in any order).
*
* Multiple regions of physical ram that should be excluded from crash dumps, or
* memory allocation, or both, can be added (in any order).
*
* After all early kernel init is done and it's time to configure all
* remainining non-excluded physical ram for use by other parts of the kernel,
* arm_physmem_init_kernel_globals() processes the hardware regions and
* exclusion regions to generate the global dump_avail and phys_avail arrays
* that communicate physical ram configuration to other parts of the kernel.
*/
#define EXFLAG_NODUMP 0x01
#define EXFLAG_NOALLOC 0x02
void arm_physmem_hardware_region(uint64_t pa, uint64_t sz);
void arm_physmem_exclude_region(vm_paddr_t pa, vm_size_t sz, uint32_t flags);
void arm_physmem_init_kernel_globals(void);
void arm_physmem_print_tables(void);
/*
* Convenience routines for FDT.
*/
#ifdef FDT
#include <machine/ofw_machdep.h>
static inline void
arm_physmem_hardware_regions(struct mem_region * mrptr, int mrcount)
{
while (mrcount--) {
arm_physmem_hardware_region(mrptr->mr_start, mrptr->mr_size);
++mrptr;
}
}
static inline void
arm_physmem_exclude_regions(struct mem_region * mrptr, int mrcount,
uint32_t exflags)
{
while (mrcount--) {
arm_physmem_exclude_region(mrptr->mr_start, mrptr->mr_size,
exflags);
++mrptr;
}
}
#endif /* FDT */
#endif