Doug Ambrisko f2521a76ed This driver attaches to the Intel VMD drive and connects a new PCI domain
starting at the max. domain, and then work down.  Then existing FreeBSD
drivers will attach.  Interrupt routing from the VMD MSI-X to the NVME
drive is not well known, so any interrupt is sent to all children that
register.

VROC used Intel meta data so graid(8) works with it. However, graid(8)
supports RAID 0,1,10 for read and write. I have some early code to
support writes with RAID 5.  Note that RAID 5 can have life issues
with SSDs since it can cause write amplification from updating the parity
data.

Hot plug support needs a change to skip the following check to work:
	if (pcib_request_feature(dev, PCI_FEATURE_HP) != 0) {
in sys/dev/pci/pci_pci.c.

Looked at by: imp, rpokala, bcr
Differential Revision:	https://reviews.freebsd.org/D21383
2019-10-10 03:12:17 +00:00

65 lines
2.2 KiB
Groff

.\"-
.\" SPDX-License-Identifier: BSD-2-Clause-FreeBSD
.\"
.\" Copyright 2019 Cisco Systems, Inc.
.\"
.\" Redistribution and use in source and binary forms, with or without
.\" modification, are permitted provided that the following conditions
.\" are met:
.\" 1. Redistributions of source code must retain the above copyright
.\" notice, this list of conditions and the following disclaimer.
.\" 2. Redistributions in binary form must reproduce the above copyright
.\" notice, this list of conditions and the following disclaimer in the
.\" documentation and/or other materials provided with the distribution.
.\"
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
.\" SUCH DAMAGE.
.\"
.\" $FreeBSD$
.\"
.Dd Octber 9, 2019
.Dt VMD 4
.Os
.Sh NAME
.Nm vmd
.Nd Intel Volume Management Device driver
.Sh SYNOPSIS
To compile this driver into the kernel, place the following lines in your
kernel configuration file:
.Bd -ragged -offset -indent
.Cd "device vmd"
.Cd "device vmd_bus"
.Ed
.Pp
Alternatively, to load the driver as a module at boot time, place the following
line in
.Xr loader.conf 5 :
.Bd -literal -offset indent
vmd_load="YES"
.Ed
.Pp
.Sh DESCRIPTION
This driver attaches to Intel VMD devices as a new PCI domain and then
triggers a probe of PCI devices.
Intel VMD is used with Intel's VROC (Virtual RAID on chip) used with
NVME drives on Skylake SP servers.
.Sh SEE ALSO
.Xr graid 8
.Sh HISTORY
The
.Nm
driver first appeared in
.Fx 13.0 .
.Sh BUGS
.Nm