2016-08-31 21:46:58 +00:00
|
|
|
/*
|
|
|
|
* CDDL HEADER START
|
|
|
|
*
|
|
|
|
* The contents of this file are subject to the terms of the
|
|
|
|
* Common Development and Distribution License Version 1.0 (CDDL-1.0).
|
|
|
|
* You can obtain a copy of the license from the top-level file
|
|
|
|
* "OPENSOLARIS.LICENSE" or at <http://opensource.org/licenses/CDDL-1.0>.
|
|
|
|
* You may not use this file except in compliance with the license.
|
|
|
|
*
|
|
|
|
* CDDL HEADER END
|
|
|
|
*/
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Copyright (c) 2016, Intel Corporation.
|
|
|
|
*/
|
|
|
|
|
|
|
|
#ifdef HAVE_LIBUDEV
|
|
|
|
|
|
|
|
#include <errno.h>
|
|
|
|
#include <fcntl.h>
|
|
|
|
#include <libnvpair.h>
|
|
|
|
#include <libudev.h>
|
|
|
|
#include <libzfs.h>
|
|
|
|
#include <pthread.h>
|
|
|
|
#include <stdlib.h>
|
|
|
|
#include <string.h>
|
|
|
|
|
|
|
|
#include <sys/sysevent/eventdefs.h>
|
|
|
|
#include <sys/sysevent/dev.h>
|
|
|
|
|
|
|
|
#include "zed_log.h"
|
|
|
|
#include "zed_disk_event.h"
|
|
|
|
#include "agents/zfs_agents.h"
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Portions of ZED need to see disk events for disks belonging to ZFS pools.
|
|
|
|
* A libudev monitor is established to monitor block device actions and pass
|
|
|
|
* them on to internal ZED logic modules. Initially, zfs_mod.c is the only
|
|
|
|
* consumer and is the Linux equivalent for the illumos syseventd ZFS SLM
|
|
|
|
* module responsible for handeling disk events for ZFS.
|
|
|
|
*/
|
|
|
|
|
|
|
|
pthread_t g_mon_tid;
|
|
|
|
struct udev *g_udev;
|
|
|
|
struct udev_monitor *g_mon;
|
|
|
|
|
|
|
|
|
|
|
|
#define DEV_BYID_PATH "/dev/disk/by-id/"
|
|
|
|
|
|
|
|
/* 64MB is minimum usable disk for ZFS */
|
|
|
|
#define MINIMUM_SECTORS 131072
|
|
|
|
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Post disk event to SLM module
|
|
|
|
*
|
|
|
|
* occurs in the context of monitor thread
|
|
|
|
*/
|
|
|
|
static void
|
|
|
|
zed_udev_event(const char *class, const char *subclass, nvlist_t *nvl)
|
|
|
|
{
|
|
|
|
char *strval;
|
|
|
|
uint64_t numval;
|
|
|
|
|
|
|
|
zed_log_msg(LOG_INFO, "zed_disk_event:");
|
|
|
|
zed_log_msg(LOG_INFO, "\tclass: %s", class);
|
|
|
|
zed_log_msg(LOG_INFO, "\tsubclass: %s", subclass);
|
|
|
|
if (nvlist_lookup_string(nvl, DEV_NAME, &strval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %s", DEV_NAME, strval);
|
|
|
|
if (nvlist_lookup_string(nvl, DEV_PATH, &strval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %s", DEV_PATH, strval);
|
|
|
|
if (nvlist_lookup_string(nvl, DEV_IDENTIFIER, &strval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %s", DEV_IDENTIFIER, strval);
|
|
|
|
if (nvlist_lookup_string(nvl, DEV_PHYS_PATH, &strval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %s", DEV_PHYS_PATH, strval);
|
|
|
|
if (nvlist_lookup_uint64(nvl, DEV_SIZE, &numval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %llu", DEV_SIZE, numval);
|
|
|
|
if (nvlist_lookup_uint64(nvl, ZFS_EV_POOL_GUID, &numval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %llu", ZFS_EV_POOL_GUID, numval);
|
|
|
|
if (nvlist_lookup_uint64(nvl, ZFS_EV_VDEV_GUID, &numval) == 0)
|
|
|
|
zed_log_msg(LOG_INFO, "\t%s: %llu", ZFS_EV_VDEV_GUID, numval);
|
|
|
|
|
|
|
|
(void) zfs_slm_event(class, subclass, nvl);
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* dev_event_nvlist: place event schema into an nv pair list
|
|
|
|
*
|
|
|
|
* NAME VALUE (example)
|
|
|
|
* -------------- --------------------------------------------------------
|
|
|
|
* DEV_NAME /dev/sdl
|
|
|
|
* DEV_PATH /devices/pci0000:00/0000:00:03.0/0000:04:00.0/host0/...
|
|
|
|
* DEV_IDENTIFIER ata-Hitachi_HTS725050A9A362_100601PCG420VLJ37DMC
|
|
|
|
* DEV_PHYS_PATH pci-0000:04:00.0-sas-0x4433221101000000-lun-0
|
|
|
|
* DEV_IS_PART ---
|
|
|
|
* DEV_SIZE 500107862016
|
|
|
|
* ZFS_EV_POOL_GUID 17523635698032189180
|
|
|
|
* ZFS_EV_VDEV_GUID 14663607734290803088
|
|
|
|
*/
|
|
|
|
static nvlist_t *
|
|
|
|
dev_event_nvlist(struct udev_device *dev)
|
|
|
|
{
|
|
|
|
nvlist_t *nvl;
|
|
|
|
char strval[128];
|
|
|
|
const char *value, *path;
|
|
|
|
uint64_t guid;
|
|
|
|
|
|
|
|
if (nvlist_alloc(&nvl, NV_UNIQUE_NAME, 0) != 0)
|
|
|
|
return (NULL);
|
|
|
|
|
|
|
|
if (zfs_device_get_devid(dev, strval, sizeof (strval)) == 0)
|
|
|
|
(void) nvlist_add_string(nvl, DEV_IDENTIFIER, strval);
|
|
|
|
if (zfs_device_get_physical(dev, strval, sizeof (strval)) == 0)
|
|
|
|
(void) nvlist_add_string(nvl, DEV_PHYS_PATH, strval);
|
|
|
|
if ((path = udev_device_get_devnode(dev)) != NULL)
|
|
|
|
(void) nvlist_add_string(nvl, DEV_NAME, path);
|
|
|
|
if ((value = udev_device_get_devpath(dev)) != NULL)
|
|
|
|
(void) nvlist_add_string(nvl, DEV_PATH, value);
|
|
|
|
value = udev_device_get_devtype(dev);
|
|
|
|
if ((value != NULL && strcmp("partition", value) == 0) ||
|
|
|
|
(udev_device_get_property_value(dev, "ID_PART_ENTRY_NUMBER")
|
|
|
|
!= NULL)) {
|
|
|
|
(void) nvlist_add_boolean(nvl, DEV_IS_PART);
|
|
|
|
}
|
|
|
|
if ((value = udev_device_get_sysattr_value(dev, "size")) != NULL) {
|
|
|
|
uint64_t numval = DEV_BSIZE;
|
|
|
|
|
|
|
|
numval *= strtoull(value, NULL, 10);
|
|
|
|
(void) nvlist_add_uint64(nvl, DEV_SIZE, numval);
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Grab the pool and vdev guids from blkid cache
|
|
|
|
*/
|
|
|
|
value = udev_device_get_property_value(dev, "ID_FS_UUID");
|
|
|
|
if (value != NULL && (guid = strtoull(value, NULL, 10)) != 0)
|
|
|
|
(void) nvlist_add_uint64(nvl, ZFS_EV_POOL_GUID, guid);
|
|
|
|
|
|
|
|
value = udev_device_get_property_value(dev, "ID_FS_UUID_SUB");
|
|
|
|
if (value != NULL && (guid = strtoull(value, NULL, 10)) != 0)
|
|
|
|
(void) nvlist_add_uint64(nvl, ZFS_EV_VDEV_GUID, guid);
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Either a vdev guid or a devid must be present for matching
|
|
|
|
*/
|
|
|
|
if (!nvlist_exists(nvl, DEV_IDENTIFIER) &&
|
|
|
|
!nvlist_exists(nvl, ZFS_EV_VDEV_GUID)) {
|
|
|
|
nvlist_free(nvl);
|
|
|
|
return (NULL);
|
|
|
|
}
|
|
|
|
|
|
|
|
return (nvl);
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Listen for block device uevents
|
|
|
|
*/
|
|
|
|
static void *
|
|
|
|
zed_udev_monitor(void *arg)
|
|
|
|
{
|
|
|
|
struct udev_monitor *mon = arg;
|
2016-10-19 19:55:59 +00:00
|
|
|
char *tmp, *tmp2;
|
2016-08-31 21:46:58 +00:00
|
|
|
|
|
|
|
zed_log_msg(LOG_INFO, "Waiting for new uduev disk events...");
|
|
|
|
|
|
|
|
while (1) {
|
|
|
|
struct udev_device *dev;
|
|
|
|
const char *action, *type, *part, *sectors;
|
|
|
|
const char *bus, *uuid;
|
|
|
|
const char *class, *subclass;
|
|
|
|
nvlist_t *nvl;
|
|
|
|
boolean_t is_zfs = B_FALSE;
|
|
|
|
|
|
|
|
/* allow a cancellation while blocked (recvmsg) */
|
|
|
|
pthread_setcancelstate(PTHREAD_CANCEL_ENABLE, NULL);
|
|
|
|
|
|
|
|
/* blocks at recvmsg until an event occurs */
|
|
|
|
if ((dev = udev_monitor_receive_device(mon)) == NULL) {
|
|
|
|
zed_log_msg(LOG_WARNING, "zed_udev_monitor: receive "
|
|
|
|
"device error %d", errno);
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
|
|
|
|
/* allow all steps to complete before a cancellation */
|
|
|
|
pthread_setcancelstate(PTHREAD_CANCEL_DISABLE, NULL);
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Strongly typed device is the prefered filter
|
|
|
|
*/
|
|
|
|
type = udev_device_get_property_value(dev, "ID_FS_TYPE");
|
|
|
|
if (type != NULL && type[0] != '\0') {
|
|
|
|
if (strcmp(type, "zfs_member") == 0) {
|
|
|
|
is_zfs = B_TRUE;
|
|
|
|
} else {
|
|
|
|
/* not ours, so skip */
|
|
|
|
zed_log_msg(LOG_INFO, "zed_udev_monitor: skip "
|
|
|
|
"%s (in use by %s)",
|
|
|
|
udev_device_get_devnode(dev), type);
|
|
|
|
udev_device_unref(dev);
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* if this is a disk and it is partitioned, then the
|
|
|
|
* zfs label will reside in a DEVTYPE=partition and
|
|
|
|
* we can skip passing this event
|
|
|
|
*/
|
|
|
|
type = udev_device_get_property_value(dev, "DEVTYPE");
|
|
|
|
part = udev_device_get_property_value(dev,
|
|
|
|
"ID_PART_TABLE_TYPE");
|
|
|
|
if (type != NULL && type[0] != '\0' &&
|
|
|
|
strcmp(type, "disk") == 0 &&
|
|
|
|
part != NULL && part[0] != '\0') {
|
|
|
|
/* skip and wait for partition event */
|
|
|
|
zed_log_msg(LOG_INFO, "zed_udev_monitor: %s waiting "
|
|
|
|
"for slice", udev_device_get_devnode(dev));
|
|
|
|
udev_device_unref(dev);
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* ignore small partitions
|
|
|
|
*/
|
|
|
|
sectors = udev_device_get_property_value(dev,
|
|
|
|
"ID_PART_ENTRY_SIZE");
|
|
|
|
if (sectors == NULL)
|
|
|
|
sectors = udev_device_get_sysattr_value(dev, "size");
|
|
|
|
if (sectors != NULL &&
|
|
|
|
strtoull(sectors, NULL, 10) < MINIMUM_SECTORS) {
|
|
|
|
udev_device_unref(dev);
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* If the blkid probe didn't find ZFS, then a persistent
|
|
|
|
* device id string is required in the message schema
|
|
|
|
* for matching with vdevs. Preflight here for expected
|
|
|
|
* udev information.
|
|
|
|
*/
|
|
|
|
bus = udev_device_get_property_value(dev, "ID_BUS");
|
|
|
|
uuid = udev_device_get_property_value(dev, "DM_UUID");
|
|
|
|
if (!is_zfs && (bus == NULL && uuid == NULL)) {
|
|
|
|
zed_log_msg(LOG_INFO, "zed_udev_monitor: %s no devid "
|
|
|
|
"source", udev_device_get_devnode(dev));
|
|
|
|
udev_device_unref(dev);
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
|
|
|
|
action = udev_device_get_action(dev);
|
|
|
|
if (strcmp(action, "add") == 0) {
|
|
|
|
class = EC_DEV_ADD;
|
|
|
|
subclass = ESC_DISK;
|
|
|
|
} else if (strcmp(action, "remove") == 0) {
|
|
|
|
class = EC_DEV_REMOVE;
|
|
|
|
subclass = ESC_DISK;
|
|
|
|
} else if (strcmp(action, "change") == 0) {
|
|
|
|
class = EC_DEV_STATUS;
|
|
|
|
subclass = ESC_DEV_DLE;
|
|
|
|
} else {
|
|
|
|
zed_log_msg(LOG_WARNING, "zed_udev_monitor: %s unknown",
|
|
|
|
action);
|
|
|
|
udev_device_unref(dev);
|
|
|
|
continue;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Special case an EC_DEV_ADD for multipath devices
|
|
|
|
*
|
|
|
|
* When a multipath device is created, udev reports the
|
|
|
|
* following:
|
|
|
|
*
|
|
|
|
* 1. "add" event of the dm device for the multipath device
|
|
|
|
* (like /dev/dm-3).
|
|
|
|
* 2. "change" event to create the actual multipath device
|
|
|
|
* symlink (like /dev/mapper/mpatha). The event also
|
|
|
|
* passes back the relevant DM vars we care about, like
|
|
|
|
* DM_UUID.
|
|
|
|
* 3. Another "change" event identical to #2 (that we ignore).
|
|
|
|
*
|
|
|
|
* To get the behavior we want, we treat the "change" event
|
|
|
|
* in #2 as a "add" event; as if "/dev/mapper/mpatha" was
|
|
|
|
* a new disk being added.
|
|
|
|
*/
|
|
|
|
if (strcmp(class, EC_DEV_STATUS) == 0 &&
|
|
|
|
udev_device_get_property_value(dev, "DM_UUID") &&
|
|
|
|
udev_device_get_property_value(dev, "MPATH_SBIN_PATH")) {
|
2016-10-19 19:55:59 +00:00
|
|
|
tmp = (char *) udev_device_get_devnode(dev);
|
|
|
|
tmp2 = get_underlying_path(NULL, tmp);
|
|
|
|
if (tmp && tmp2 && (strcmp(tmp, tmp2) != 0)) {
|
|
|
|
/*
|
|
|
|
* We have a real underlying device, which
|
|
|
|
* means that this multipath "change" event is
|
|
|
|
* an "add" event.
|
|
|
|
*
|
|
|
|
* If the multipath device and the underlying
|
|
|
|
* dev are the same name (i.e. /dev/dm-5), then
|
|
|
|
* there is no real underlying disk for this
|
|
|
|
* multipath device, and so this "change" event
|
|
|
|
* really a multipath removal.
|
|
|
|
*/
|
|
|
|
class = EC_DEV_ADD;
|
|
|
|
subclass = ESC_DISK;
|
|
|
|
} else {
|
|
|
|
/* multipath remove, ignore it. */
|
|
|
|
}
|
|
|
|
free(tmp2);
|
2016-08-31 21:46:58 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
if ((nvl = dev_event_nvlist(dev)) != NULL) {
|
|
|
|
zed_udev_event(class, subclass, nvl);
|
|
|
|
nvlist_free(nvl);
|
|
|
|
}
|
|
|
|
|
|
|
|
udev_device_unref(dev);
|
|
|
|
}
|
|
|
|
|
|
|
|
return (NULL);
|
|
|
|
}
|
|
|
|
|
|
|
|
int
|
|
|
|
zed_disk_event_init()
|
|
|
|
{
|
|
|
|
int fd, fflags;
|
|
|
|
|
|
|
|
if ((g_udev = udev_new()) == NULL) {
|
|
|
|
zed_log_msg(LOG_WARNING, "udev_new failed (%d)", errno);
|
|
|
|
return (-1);
|
|
|
|
}
|
|
|
|
|
|
|
|
/* Set up a udev monitor for block devices */
|
|
|
|
g_mon = udev_monitor_new_from_netlink(g_udev, "udev");
|
|
|
|
udev_monitor_filter_add_match_subsystem_devtype(g_mon, "block", "disk");
|
|
|
|
udev_monitor_filter_add_match_subsystem_devtype(g_mon, "block",
|
|
|
|
"partition");
|
|
|
|
udev_monitor_enable_receiving(g_mon);
|
|
|
|
|
|
|
|
/* Make sure monitoring socket is blocking */
|
|
|
|
fd = udev_monitor_get_fd(g_mon);
|
|
|
|
if ((fflags = fcntl(fd, F_GETFL)) & O_NONBLOCK)
|
|
|
|
(void) fcntl(fd, F_SETFL, fflags & ~O_NONBLOCK);
|
|
|
|
|
|
|
|
/* spawn a thread to monitor events */
|
|
|
|
if (pthread_create(&g_mon_tid, NULL, zed_udev_monitor, g_mon) != 0) {
|
|
|
|
udev_monitor_unref(g_mon);
|
|
|
|
udev_unref(g_udev);
|
|
|
|
zed_log_msg(LOG_WARNING, "pthread_create failed");
|
|
|
|
return (-1);
|
|
|
|
}
|
|
|
|
|
|
|
|
zed_log_msg(LOG_INFO, "zed_disk_event_init");
|
|
|
|
|
|
|
|
return (0);
|
|
|
|
}
|
|
|
|
|
|
|
|
void
|
|
|
|
zed_disk_event_fini()
|
|
|
|
{
|
|
|
|
/* cancel monitor thread at recvmsg() */
|
|
|
|
(void) pthread_cancel(g_mon_tid);
|
|
|
|
(void) pthread_join(g_mon_tid, NULL);
|
|
|
|
|
|
|
|
/* cleanup udev resources */
|
|
|
|
udev_monitor_unref(g_mon);
|
|
|
|
udev_unref(g_udev);
|
|
|
|
|
|
|
|
zed_log_msg(LOG_INFO, "zed_disk_event_fini");
|
|
|
|
}
|
|
|
|
|
|
|
|
#else
|
|
|
|
|
|
|
|
#include "zed_disk_event.h"
|
|
|
|
|
|
|
|
int
|
|
|
|
zed_disk_event_init()
|
|
|
|
{
|
|
|
|
return (0);
|
|
|
|
}
|
|
|
|
|
|
|
|
void
|
|
|
|
zed_disk_event_fini()
|
|
|
|
{
|
|
|
|
}
|
|
|
|
|
|
|
|
#endif /* HAVE_LIBUDEV */
|