- Use pci_get_device() and pci_get_vendor() when we only want one part
of the device id. - Use BAR2 rather than BAR0 for the Rocketport UPCI 8O card. I suspect that other UPCI cards might need to use BAR2 as well. Tested by: wsk at gddsn dot org dot cn MFC after: 1 week
This commit is contained in:
parent
379ba85322
commit
04f716a436
@ -67,6 +67,7 @@ __FBSDID("$FreeBSD$");
|
||||
#define RP_DEVICE_ID_4J 0x0007
|
||||
#define RP_DEVICE_ID_6M 0x000C
|
||||
#define RP_DEVICE_ID_4M 0x000D
|
||||
#define RP_DEVICE_ID_UPCI_8O 0x0805
|
||||
|
||||
/**************************************************************************
|
||||
MUDBAC remapped for PCI
|
||||
@ -129,7 +130,7 @@ rp_pciprobe(device_t dev)
|
||||
char *s;
|
||||
|
||||
s = NULL;
|
||||
if ((pci_get_devid(dev) & 0xffff) == RP_VENDOR_ID)
|
||||
if (pci_get_vendor(dev) == RP_VENDOR_ID)
|
||||
s = "RocketPort PCI";
|
||||
|
||||
if (s != NULL) {
|
||||
@ -177,7 +178,14 @@ rp_pciattach(device_t dev)
|
||||
|
||||
ctlp->bus_ctlp = NULL;
|
||||
|
||||
ctlp->io_rid[0] = 0x10;
|
||||
switch (pci_get_device(dev)) {
|
||||
case RP_DEVICE_ID_UPCI_8O:
|
||||
ctlp->io_rid[0] = PCIR_BAR(2);
|
||||
break;
|
||||
default:
|
||||
ctlp->io_rid[0] = PCIR_BAR(0);
|
||||
break;
|
||||
}
|
||||
ctlp->io[0] = bus_alloc_resource_any(dev, SYS_RES_IOPORT,
|
||||
&ctlp->io_rid[0], RF_ACTIVE);
|
||||
if(ctlp->io[0] == NULL) {
|
||||
@ -188,7 +196,7 @@ rp_pciattach(device_t dev)
|
||||
|
||||
num_aiops = sPCIInitController(ctlp,
|
||||
MAX_AIOPS_PER_BOARD, 0,
|
||||
FREQ_DIS, 0, (pci_get_devid(dev) >> 16) & 0xffff);
|
||||
FREQ_DIS, 0, pci_get_device(dev));
|
||||
|
||||
num_ports = 0;
|
||||
for(aiop=0; aiop < num_aiops; aiop++) {
|
||||
|
Loading…