Normalize the diagnostics list.
This commit is contained in:
parent
e9d412af6b
commit
367022ebe2
@ -65,54 +65,43 @@ Physical devices which are not claimed by a logical
|
||||
device are presented on SCSI channels which match the physical channels
|
||||
on the controller.
|
||||
.Sh DIAGNOSTICS
|
||||
Controller initialisation phase:
|
||||
.Ss Controller initialisation phase
|
||||
.Bl -diag
|
||||
.It "mly%d: controller initialisation started"
|
||||
.It "mly%d: initialisation complete"
|
||||
.El
|
||||
.Pp
|
||||
The controller firmware has started initialisation.
|
||||
Normally this process is performed by the controller BIOS,
|
||||
but the driver may need
|
||||
to do this in cases where the BIOS has failed, or is not compatible
|
||||
(eg. on non-x86 systems).
|
||||
.Bl -diag
|
||||
.It "mly%d: drive spinup in progress"
|
||||
.El
|
||||
.Pp
|
||||
Drive startup is in progress; this may take several minutes.
|
||||
.Bl -diag
|
||||
.It "mly%d: mirror race recovery failed, one or more drives offline"
|
||||
.It "mly%d: mirror race recovery in progress"
|
||||
.It "mly%d: mirror race recovery on a critical drive"
|
||||
.El
|
||||
.Pp
|
||||
These error codes are undocumented.
|
||||
.Bl -diag
|
||||
.It "mly%d: FATAL MEMORY PARITY ERROR"
|
||||
.El
|
||||
.Pp
|
||||
Firmware detected a fatal memory error; the driver will not attempt to
|
||||
attach to this controller.
|
||||
.Bl -diag
|
||||
.It "mly%d: unknown initialisation code %x"
|
||||
.El
|
||||
.Pp
|
||||
An unknown error occurred during initialisation; it will be ignored.
|
||||
.Pp
|
||||
Driver initialisation/shutdown phase:
|
||||
.El
|
||||
.Ss Driver initialisation/shutdown phase
|
||||
.Bl -diag
|
||||
.It "mly%d: can't enable busmaster feature"
|
||||
.It "mly%d: memory window not available"
|
||||
.It "mly%d: can't allocate register window"
|
||||
.It "mly%d: can't allocate interrupt"
|
||||
.It "mly%d: can't set up interrupt"
|
||||
.El
|
||||
.Pp
|
||||
The system's PCI BIOS has not correctly configured the controller's
|
||||
PCI interface; initialisation has failed and the driver will not
|
||||
attach to this controller.
|
||||
.Bl -diag
|
||||
.It "mly%d: can't allocate parent DMA tag"
|
||||
.It "mly%d: can't allocate buffer DMA tag"
|
||||
.It "mly%d: can't allocate command packet DMA tag"
|
||||
@ -120,24 +109,19 @@ attach to this controller.
|
||||
.It "mly%d: can't allocate s/g table"
|
||||
.It "mly%d: can't allocate memory mailbox DMA tag"
|
||||
.It "mly%d: can't allocate memory mailbox"
|
||||
.El
|
||||
.Pp
|
||||
A resource allocation error occurred while initialising the driver;
|
||||
initialisation has failed and the driver will not attach to this
|
||||
controller.
|
||||
.Bl -diag
|
||||
.It "mly%d: BTL rescan result corrupted"
|
||||
.El
|
||||
.Pp
|
||||
The results of a scan for an attached device were corrupted.
|
||||
One or more devices may not be correctly reported.
|
||||
.Bl -diag
|
||||
.It "mly%d: flushing cache..."
|
||||
.El
|
||||
.Pp
|
||||
The controller cache is being flushed prior to detach or shutdown.
|
||||
.Pp
|
||||
Operational diagnostics:
|
||||
.El
|
||||
.Ss Operational diagnostics
|
||||
.Bl -diag
|
||||
.It "mly%d: physical device %d:%d online"
|
||||
.It "mly%d: physical device %d:%d standby"
|
||||
@ -189,11 +173,9 @@ Operational diagnostics:
|
||||
.It "mly%d: physical device %d:%d offline"
|
||||
.It "mly%d: sense key %d asc %02x ascq %02x"
|
||||
.It "mly%d: info %4D csi %4D"
|
||||
.El
|
||||
.Pp
|
||||
The reported event refers to the physical device at the given channel:target
|
||||
address.
|
||||
.Bl -diag
|
||||
.It "mly%d: logical device %d (%s) consistency check started"
|
||||
.It "mly%d: logical device %d (%s) consistency check completed"
|
||||
.It "mly%d: logical device %d (%s) consistency check cancelled"
|
||||
@ -225,11 +207,9 @@ address.
|
||||
.It "mly%d: logical device %d (%s) bad data block found"
|
||||
.It "mly%d: logical device %d (%s) read of data block in bdt"
|
||||
.It "mly%d: logical device %d (%s) write back data for disk block lost"
|
||||
.El
|
||||
.Pp
|
||||
The event report will include the name of the SCSI device which has
|
||||
attached to the device if possible.
|
||||
.Bl -diag
|
||||
.It "mly%d: enclosure %d fan %d failed"
|
||||
.It "mly%d: enclosure %d fan %d ok"
|
||||
.It "mly%d: enclosure %d fan %d not present"
|
||||
@ -243,11 +223,9 @@ attached to the device if possible.
|
||||
.It "mly%d: enclosure %d unit %d access critical"
|
||||
.It "mly%d: enclosure %d unit %d access ok"
|
||||
.It "mly%d: enclosure %d unit %d access offline"
|
||||
.El
|
||||
.Pp
|
||||
These events refer to external enclosures by number.
|
||||
The driver does not attempt to name the enclosures.
|
||||
.Bl -diag
|
||||
.It "mly%d: controller cache write back error"
|
||||
.It "mly%d: controller battery backup unit found"
|
||||
.It "mly%d: controller battery backup unit charge level low"
|
||||
@ -258,9 +236,9 @@ The driver does not attempt to name the enclosures.
|
||||
.It "mly%d: controller memory soft ecc error"
|
||||
.It "mly%d: controller memory hard ecc error"
|
||||
.It "mly%d: controller battery backup unit failed"
|
||||
.El
|
||||
.Pp
|
||||
These events report controller status changes.
|
||||
.El
|
||||
.Sh BUGS
|
||||
The driver does not yet provide an external management interface.
|
||||