Don't try to re-initialize already preseted regulator.

Don't set initial voltage for regulators having their voltage already
in allowed range. As side effect of this change, we don't try to set
initial voltage for fixed voltage regulators - these don't have impemented
voltage set  method so their initialization has always failed.

MFC after:	3 weeks
This commit is contained in:
Michal Meloun 2020-04-29 13:45:21 +00:00
parent 4c291cb857
commit 726122cfda

View File

@ -105,6 +105,7 @@ struct rk805_softc {
static int rk805_regnode_status(struct regnode *regnode, int *status);
static int rk805_regnode_set_voltage(struct regnode *regnode, int min_uvolt,
int max_uvolt, int *udelay);
static int rk805_regnode_get_voltage(struct regnode *regnode, int *uvolt);
static struct rk805_regdef rk805_regdefs[] = {
{
@ -366,13 +367,21 @@ rk805_regnode_init(struct regnode *regnode)
{
struct rk805_reg_sc *sc;
struct regnode_std_param *param;
int rv, udelay, status;
int rv, udelay, uvolt, status;
sc = regnode_get_softc(regnode);
dprintf(sc, "Regulator %s init called\n", sc->def->name);
param = regnode_get_stdparam(regnode);
if (param->min_uvolt == 0)
return (0);
/* Check that the regulator is preset to the correct voltage */
rv = rk805_regnode_get_voltage(regnode, &uvolt);
if (rv != 0)
return(rv);
if (uvolt >= param->min_uvolt && uvolt <= param->max_uvolt)
return(0);
/*
* Set the regulator at the correct voltage if it is not enabled.
* Do not enable it, this is will be done either by a