revision 1.106
date: 2001/11/09 15:01:57; author: augustss; state: Exp; lines: +73 -57
Fix a bug in xfer abort processing when the HC executes ahead of what
the driver aborts.
Don't block RHSC interrupts.
revision 1.103
date: 2001/09/11 07:00:19; author: augustss; state: Exp; lines: +4 -1
Don't go top mode OPERATIONAL (before reset) on startup even
if BIOS claims to have initialized the controller.
hw.syscons.saver.keybonly: used to specify that only input is to
interrupt the screensaver. This allows one to run a chatty console
app but still have the screen blank out until a key is pressed.
There should probably also be an ioctl for this, we'll do that later.
hw.syscons.saver.blanktime: exports the screensaver timeout via sysctl.
Submitted by: Olivier Houchard <doginou@cognet.ci0.org>
interface that is compatible with the LUCENT or HERMES firmware.
Instead, it is like the various No Wires Necessary products that were
produced a while ago and then sold to intersil. It will require a
different driver altogether. Remove it from the list of supported
cards.
The 3CRWE777A apperas to be a re-badged SMC 2602W card, so the driver
appears to support it. Add it to the list.
Thanks to Todd Miller for loaning me the card during tonight's FRUUG
meeting for testing against CU's wireless infrastructure.
Grumble. I've seen better documented architectures out of Redmond.
Redo fabric evaluation to not use GET ALL NEXT (GA_NXT). Switches seem
to be trying to wriggle out of supporting this well. Instead, use
GID_FT to get a list of Port IDs and then use GPN_ID/GNN_ID to find the
port and node wwn. This should make working on fabrics a bit cleaner and
more stable.
This also caused some cleanup of SNS subcommand canonicalization so that
we can actually check for FS_ACC and FS_RJT, and if we get an FS_RJT,
print out the reason and explanation codes.
We'll keep the old GA_NXT method around if people want to uncomment a
controlling definition in ispvar.h.
This also had us clean up ISPASYNC_FABRICDEV to use a local lportdb argument
and to have the caller explicitly say that a device is at the end of the
fabric list.
MFC after: 1 week
time-of-day clocks, ported from NetBSD. The front-ends are expected
to be at least partly machine-dependent; the sparc64 EBus and SBus
ones will be commited to MD directories for now (in a subsequent commit).
wi.c 1.64: Table driven IDs (ichiro)
1.59: Don't use magic numbers (ichiro)
Also, added Sony, Lucent Embedded Ids and fix minor bugs for lucent
cards (and submit those changes back to ichiro-san)
Obtained from: NetBSD
most cases NULL is passed, but in some cases such as network driver locks
(which use the MTX_NETWORK_LOCK macro) and UMA zone locks, a name is used.
Tested on: i386, alpha, sparc64