This avoids the unit number from going up indefinitely when
diconnecting and connecting 2 devices alternately.
Noticed by: nsayer (quite a while ago)
And stop calling DEVICE_NOMATCH at probe repeatedly. This stops the
message on the PCI VGA board from being printed when loading a PCI driver.
platform we're running on so we know how many bits to reserve at the top
end for the 'hose' value. It turns out that there's *just* enough room
to support all possible hoses on TurboLaser.
Reviewed by: gallatin@freebsd.org, dfr@free3bsd.org
This makes it possible to handle the done queue even when the end of tail
TD has ended up on the done queue as well (the xfer in this case is NULL
but the next field is valid, so we simply skip that element.
Make sure we mark all the handled transfers as handled.
Stop using powerhooks. They are a NetBSD-ism.
the unwary if the code were called in slightly different ways.
1) In ufs_bmaparray() the code for calculating 'runb' will stop one block
short of the first entry in an indirect block. i.e. if an indirect block
contains N block numbers b[0]..b[N-1] then the code will never check if
b[0] and b[1] are sequential. For reference, compare with the equivalent
code that deals with direct blocks.
2) In ufs_lookup() there is an off-by-one error in the test that checks
if dp->i_diroff is outside the range of the the current directory size.
This is completely harmless, since the following while-loop condition
'dp->i_offset < endsearch' is never met, so the code immediately
does a second pass starting at dp->i_offset = 0.
3) Again in ufs_lookup(), the condition in a sanity check is wrong
for directories that are longer than one block. This bug means that
the sanity check is only effective for small directories.
Submitted by: Ian Dowse <iedowse@maths.tcd.ie>
necessary. Pass an absolute block number too, instead of receiving a
relative one in realstrategy(), as bcache_strategy() requires this.
The fix is sligthly different from the one in the PR.
PR: 17098
Submitted by: John Hood <jhood@sitaranetworks.com>
was the last unit number received. If it changes, it flushes the cache.
Add bcache_flash().
The actual fix is sligthly different from the one in the PR.
PR: 17098
Submitted by: John Hood <jhood@sitaranetworks.com>
flushed if the unit changes. Compute the absolute offset before
bcache_strategy() instead of after.
The actual fix is sligthly different for the one in the PR.
PR: 17098
Submitted by: John Hood <jhood@sitaranetworks.com>
to recycle full fsids after only 16 mount/unmount's. This is probably
too often for exported fsids. Now we recycle the full fsids only
after 2^16 mount/ umount's and only ensure uniqueness in the lower 16
bits if there have been <= 256 calls to vfs_getnewfsid() since the
system started.
Previously, it was being called whether it was needed or not and the
ASU flag was being set (as a side affect of calling 'suser()') in
cases where superuser privileges were not actually needed. This was
all pointed out to me by Bruce Evans.
Reviewed by: bde
- Make iface nodes removable on shutdown since FreeBSD now supports
removable interfaces
- Simplify supporting new protocols using family_enqueue(); add a
few new ones including IPv6
- Add support for configurable interface mode using new
NGM_IFACE_POINT2POINT and NGM_IFACE_BROADCAST control messages
- Remove NGM_IFACE_GET_IFADDRS control message; it just duplicates
the functionality of SIOCGIFCONF