usage for a subcommand, so no 'usage' function has to be implemented
in class library.
- Bump version number as it breaks ABI, but don't provide backward
compatibility, because there are probably no external consumers of this
geom(8).
This allows to print more precise usage for standard commands and simplify
class libraries a bit.
MFC after: 1 week
warning on 64-bit platforms. Explicitly cast these values to int
to work around this issue, as these values are tend to be small.
Spotted by: ia64 tinderbox
providers.
This prevents from listing geoms like <name>.sync which can be confusing.
It still allows to show details about it by giving its name when listing.
MFC after: 1 week
shared-last-sector problem.
After this change, even if there is more than one provider with the same
last sector, the proper one will be chosen based on its size.
It still doesn't fix the 'c' partition problem (when da0s1 can be confused
with da0s1c) and situation when 'a' partition starts at offset 0
(then da0s1a can be confused with da0s1 and da0s1c). One can use '-h'
option there, when creating device or avoid sharing last sector.
Actually, when providers share the same last sector and their size is equal,
they provide exactly the same data, so the name (da0s1, da0s1a, da0s1c)
isn't important at all.
- Provide backward compatibility.
- Update copyright's year.
MFC after: 1 week
the given providers. Without even one of the configured components there
should be no way to get the secret.
Supported by: WHEEL Sp. z o.o.
http://www.wheel.pl
After this change, when component is disconnected because of an I/O error,
it will not be connected and synchronized automatically, it will be logged
as broken and skipped. Autosynchronization can occur, when component is
disconnected (on orphan event) and connected again - there were no I/O
error, so there is no need to not connected the component, but when there were
writes while it wasn't connected, it will be synchronized.
This fix cases, when component is disconnected because of I/O error and can be
connected again and again.
- Bump version number.
- Implement backward compatibility mechanism. After this change when metadata in
old version is detected, it is automatically upgraded to the new (current)
version.
After this change, when component is disconnected because of an I/O error,
it will not be connected and synchronized automatically, it will be logged
as broken and skipped. Autosynchronization can occur, when component is
disconnected (on orphan event) and connected again - there were no I/O
error, so there is no need to not connected the component, but when there were
writes while it wasn't connected, it will be synchronized.
This fix cases, when component is disconnected because of I/O error and can be
connected again and again.
- Bump version number.
- Add version change history.
- Implement backward compatibility mechanism. After this change when metadata in
old version is detected, it is automatically upgraded to the new (current)
version.