reject. For example:
Checking for rejected mail hosts:
48 getherbalnow.info (451... resolve)
46 absorb.com (451... resolve)
4 tgmart01.codns.com (553... exist)
3 kali.com.cn (451... resolve)
2 genie.com (451... resolve)
1 zv.qy (553... exist)
1 zd.hinet.hr (553... exist)
....
The bit in parenthesis is the reject code and the last word on the line -
enough to give the admin a better chance of seeing real problems (hopefully!).
While I'm here, remove the "<" at the start of rejects coming from "from"
addresses without a name@ part.
I had to rewrite the patch given by the submitter as this script has been
sed'ified (used to be perl) and I think the reject code is useful....
PR: 17377
Idea from: root at ns dot internet dot dk
MFC after: 7 days
- add udav(4)
In the scsi-controller-regex:
- correct an entry
- move another one to the right place
- add a bunch of missing drivers
Glanced at by: trhodes (scsi-controller-regex part)
MFC after: 3 days
1. Feature: for flexibility reasons and as a prerequisite to clean
shutdowns, allow the configuration of a stop/shutdown command
via rc.conf variable "jail_<name>_exec_stop" in addition to the
start/boot command (rc.conf variable "jail_<name>_exec_start"). For
backward compatibility reasons, rc.conf variable "jail_<name>_exec"
is still supported, too.
2. Debug: Add the used boot/shutdown commands to the debug output of
the /etc/rc.d/jail script, too.
3. Security: Run the Jail start/boot command in a cleaned environment
to not leak information from the host to the Jail during startup.
4. Feature: Run the Jail stop/shutdown command "jail_<name>_exec_stop" on
"/etc/rc.d/jail stop <name>" to allow a graceful shutdown of the Jail
before its processes are just killed.
5. Bugfix: When killing the remaining Jail processes give the processes
time to actually perform their termination sequence. Without this the
subsequent umount(8) operations usually fail because the resources
are still in use. Additionally, if after trying to TERM-inate the
processes there are still processes hanging around, finally just KILL
them.
6. Bugfix: In rc.shutdown, if running inside a Jail, skip the /etc/rc.d/*
scripts which are flagged with the KEYWORD "nojail" to allow the
correct operation of rc.shutdown under jail_<name>_exec_stop="/bin/sh
/etc/rc.shutdown". This is analogous to what /etc/rc does inside a Jail.
Now the following typical host-configuration for two Jails works as
expected and correctly boots and shutdowns the Jails:
-----------------------------------------------------------
# /etc/rc.conf:
jail_enable="YES"
jail_list="foo bar"
jail_foo_rootdir="/j/foo"
jail_foo_hostname="foo.example.com"
jail_foo_ip="192.168.0.1"
jail_foo_devfs_enable="YES"
jail_foo_mount_enable="YES"
jail_foo_exec_start="/bin/sh /etc/rc"
jail_foo_exec_stop="/bin/sh /etc/rc.shutdown"
jail_bar_rootdir="/j/bar"
jail_bar_hostname="bar.example.com"
jail_bar_ip="192.168.0.2"
jail_bar_devfs_enable="YES"
jail_bar_mount_enable="YES"
jail_bar_exec_start="/path/to/kjailer -v"
jail_bar_exec_stop="/bin/sh -c 'killall kjailer && sleep 60'"
-----------------------------------------------------------
# /etc/fstab.foo
/v/foo /j/foo/v/foo nullfs rw 0 0
-----------------------------------------------------------
# /etc/fstab.bar
/v/bar /j/bar/v/bar nullfs rw 0 0
-----------------------------------------------------------
Reviewed by: freebsd-hackers
MFC after: 2 weeks
rebadged Xircom REM56 RealPort card. Short MFC timeout to beat the 4.11
code freeze.
PR: 53027
Submitted by: John Merryweather Cooper <coop9211 at uidaho dot edu>
Approved by: imp (mentor)
MFC after: 2 days
ifnet_rename() to support situations where rc.conf's $network_interfaces
variable is set to an explicit list of network interfaces (instead of
the default "auto").
Using "list_network_interfaces all" resulted in using
$network_interfaces for both interface _renaming_ and interface
_configuration_ which obviously cannot work either before (if the
new name is in $network_interfaces) or after (if the old name is in
$network_interfaces) renaming the interface.
can't be removed as ofw_console(4) and zs(4) use them so one has to
live with some complaints about non-existent devices at boot time and
remove the respective entries locally for now.
adapters from usbd.conf to devd.conf. USB ethernet devices were
already handled in devd.conf so this just removes their usbd.conf
entry.
PR: conf/73799
packet counts by pf(4).
This adds a ``daily_status_security_pfdenied_enable'' variable to
periodic.conf, which defaults to ``YES'' as the matching IPF(W) versions.
The output will look like this (line wrapped):
pf denied packets:
> block drop log on rl0 proto tcp all [ Evaluations: 504986 Packets: 0
Bytes: 0 States: 0 ]
> block drop log on rl0 all [ Evaluations: 18559 Packets: 427 Bytes: 140578
States: 0 ]
Submitted by: clive (thanks a lot!)
MFC after: 2 weeks
this feature for a jail named foo :
jail_foo_mount_enable="YES"
jail_foo_fstab="/etc/fstab.foo"
The second line is actually useless, since the code defaults to
using "/etc/fstab.$jailname" as the fstab file if none is specified.
MFC after: 3 days
Submitted by: Jeremie Le Hen <jeremie@le-hen.org>
These can be used to pass extra options to the mdmfs(8) utility,
to customize the finer details of the md file system creation
(i.e. to turn on/off softupdates, to specify a default owner for md
filesystem, etc).
Use these two new flags to mount tmpmfs and varmfs without
softupdates, since it doesn't make much sense to use SU on
malloc-backed file systems.
Reviewed by: mtm
Inspired by: J. D. Bronson, jbronson at wixb dot com
user (for creation of the zone journal file). This is separate from the
master/ directory for security. Give an example dynamic zone in the
sample named.conf.
Approved by: dougb
Noticed by: Eivind Olsen <eivind at aminor.no>
MFC after: 1 week
on the system.
To start/stop/check on a specific device give the device name as
the second argument to the script:
# /etc/rc.d/moused start ums0
To use different rc.conf(5) knobs with different mice use the device
name as part of the knob. For example, if the mouse device is ums0, then:
moused_ums0_enable=yes
moused_ums0_flags="-z 4"
moused_ums0_port="/dev/ums0"
Starting rc.d/moused without the device argument will use the standard
moused_* flags. So, this commit should not disrupt or change current usage.
To preserve current behaviour with respect to usb mice, which appear
automatically when inserted, there is a new knob, moused_nondefault_enable,
which will treat any devices without rc.conf knobs as enabled.
To minimize knobs in /etc/rc.conf, the device file and pid file are
auto-computed, so that in the typical case for a usb mouse you don't
need to add anything extra in /etc/rc.conf to get it working.
Additionally, this updates /etc/usbd.conf to use the rc.d/moused script so
people don't have to modify it to configure their usb mouse anymore.
MFC after: 1 month
unbreak /etc/rc.d/root for diskless systems that get their root
filesystem from a read-only NFS mount.
PR: conf/72927
Submitted by: Ralf Wenk <RZ-FreeBSD1004@fh-karlsruhe.de>
Reviewed by: brooks
do not have these device special files. Where this previously failed
quietly, it now emits annoying but complete messages at best and
incomprehensible prefixes on average. During all of October, this is
a string of 16 O's, as in:
:
Starting inetd.
Sun Oct 17 15:09:09 PDT 2004
OOOOOOOOOOOOOOOO
FreeBSD/ia64 (itanium.pn.xcllnt.net) (ttyu2)
login:
pointed out that /usr/local/etc/rc.d/000.pkgtools.sh installed
with the portupgrade does an equivalent thing, so I personally
would like to see the change reverted, but let David handle it.
/etc/namedb symlink is created.
2. Incorporate Brian's suggestion to make the link relative. This
is necessary to handle situations (such as mergemaster) where the
user is building a tree in a seperate environment. This will also
fix the problem with the way DESTDIR is set in 'make release'.
3. Add a new knob, NO_BIND_MTREE, as suggested by the folks who
already have stuff in /var/named that they don't want me to mess with.
4. Update make.conf(5) with the new stuff, and correct a few paths
that have changed since I last updated it.
device
device.bde
/dev/device
/dev/device.bde
- Fix stop routine:
+ There don't have to be file system mounted on gbde device,
so ignore errors from umount(8).
+ Only detach existing gbde devices.
I used ugly "/dev/${parent}" instead of "${parentdev}", because "/dev/"
prefix for devices listed in gbde_devices variable is optional.
Reported by: Sean McNeil <sean@mcneil.com>
install now complains about ttyu0/ttyu1 not existing at boot time.
Since users wanting the uart based devices as terminals will need
to do something special to get them anyway set it up so a default
config doesn't complain.
MFC after: 3 days
authoritative servers.
2. Add an IPv4 listen-on option for 127.0.0.1, which is appropriate
for the default use as a local resolver.
3. Add a commented out listen-on-v6 option.
so we'll use the more secure default till I have a chance to prove
myself wrong. :)
Add a /var/stats directory to be enabled in named.conf.
Submitted by: gshapiro
to NO of course). Provide a basic ruleset file, rc.bsdextended, but allow
the filename to be overridden through rc.conf.
Discussed with: rwatson (awhile ago)
1. Update text about later BINDs using a pseudo-random, unpriviliged
query port for UDP by default.
2. We are now running in a sandbox by default, with a dedicated dump
directory, so remove the stale comment.
3. The topology configuration is not for the faint of heart, so
remove the commented example.
4. Tighten up some language a bit.
5. s/secondary/slave/
6. No need for the example about a bind-owned directory for slave zones.
7. Change domain.com to example.com in the example, per RFC 2606.
8. Update the path for slave zones in the example.
- Thanks to Scot Hetzel <swhetzel@gmail.com>
There is more work to do here, but this is an improvement.
by default when named is enabled. Also, improve our default directory
layout by creating /var/named/etc/namedb/{master|slave} directories,
and use the former for the generated localhost* files.
Rather than using pax to copy device entries, mount devfs in the
chroot directory.
There may be some corner cases where things need to be adjusted,
but overall this structure has been well tested on a production
network, and should serve the needs of the vast majority of users.
UPDATING has instructions on how to do the conversion for those
with existing configurations.
NO_BIND_DNSSEC, NO_BIND_ETC, NO_BIND_NAMED, and NO_BIND_UTILS.
2. Make creation of directories in /usr/include that are only needed
in the WITH_BIND_LIBS case conditional.
Reviewed by: ru, des
chrooted the pid symlink code should not fire. Also, remove the quotes
around the chroot variable in the rndc-confgen invocation so that if
not chrooted the command will still succeed.
Pointed out by: Sean McNeil <sean@mcneil.com>