the ongoing re-alignment of ordering that is necessary as a result of
including local scripts in the base rcorder. [1]
Accomplish this by removing the BEFORE's, and using REQUIRE instead.
This makes the dependencies more obvious, and less susceptible to turning
circular and/or nonsensical when seemingly innocent changes are made
in one place and not another.
Requested by: delphij [1]
and not under machdep as the behaviour is controlled by the process.
When PSR.ac is set the process expects to receive a SIGBUS. Otherwise
the processor or the kernel will emulate the misaligned memory access.
MFC after: 3 days
1. Remove a now-spurious NetBSD CVS Id, as we are no longer synching work
2. Remove a now-spurious BEFORE, since ntpdate now REQUIRE's named
3. Replace the call to set rcvar with what that function would output,
and generally reduce indirection ($name -> named) since it's highly
unlikely the name of the named process or service will change any time soon.
4. Resort the order the variables at the top of the file to a more
traditional format, and remove a spurious required_dirs from the top, as it
works better after load_rc_config.
5. We do not want the default reload method with named, so define a simple
but appropriate substitute using rndc. If I were writing this script for
the first time I would not include this at all, since it's preferable to
control a running daemon with rndc to start with, but given that this is
already here, let's do it right. I hope that future generations will
however resist the tempation to add reconfig to extra_commands.
6. By the same token, we want to use rndc to shut down named, but given
that by defining a stop function we lose the "find the process by its
pid file in an emergency" goodness of rc.subr, try to do something useful
in the event that rndc is not available, and keep the user informed.
7. Replace some "test -f" with "test -r" to handle the unlikely event
that the relevant file exists, but is unreadable.
8. Twiddle whitespace in a few areas, remove a spurious blank line,
a bogus double space, and try to do better indenting.
9. Improve generation of the rndc.key file significantly
a. If for some reason a user has an rndc.conf file, assume that they
did that on purpose, and hence know what they are doing, so leave them alone.
b. Introduce a named_uid configuration variable so that the user which owns
the rndc.key file and the user named runs as always match, and is more
easily configurable. This should dramatically reduce problems with rndc.
c. Also test that the rndc.key file size is greater than zero, rather than
simply that the file exists. I have seen at least one user report this exact
problem, and although neither of us is sure where the empty file came from,
the fix is simple, so include it.
d. Rather than try to create an rndc.key file in both /etc/namedb and the
chroot'ed /etc/namedb, assume that they are be the same (which they should
be), and only create the file in the chroot'ed version of the directory.
This partially addresses the problem described in conf/73929, but I have
not yet finished thinking about the PREFIX issue that PR also raises.
As a result of introducing the named_uid knob, the default named_flags
are now empty.
Update defaults/rc.conf and rc.conf(5) to reflect these changes.
64.15.205.248 address, change host to "foobar". This won't be
resolvable in most cases, so administrator will need to change it.
Also do not send our trap messages to 64.15.205.248, use localhost
as default traphost.
RSC (Remote System Control) connected via uart2 as console working out
of the box. On machines that use uart2 to connect a keyboard and thus
the ttyu2 node doesn't exist this will trigger a warning from getty(8)
but cause no real harm.
MFC after: 1 week
Allow user to decide if SAD and SPD entries should be flushed on 'reload'.
With this change flush/spdflush is not done automatically (it could still
be done from ipsec.conf).
supported and that users of REFUSE directives should update their
entire ports tree before asking for help on the mailing lists.
Requested by: kris
MFC after: 3 days
RELENG_6 this will be a noop, however as we introduce local
startup scripts to the base rcorder, we'll see more cases
where the previous status quo will need to be made explicit
to avoid having it disrupted when random local scripts are
added to the mix.
were now sticky. This script was deleting /boot/nextkernel on boot, but
there is no code in the tree that creates that file since revision 1.15
of src/sbin/reboot/reboot.c.
nextboot(8) creates /boot/nextboot.conf, so remove that instead.
Approved by: jhb (proxy mentor)
MFC after: 1 week
ldconfig. Build the cache in a temporary directory and only install it
if it's actually different that the installed one.
Also, use "cat tmp > real" to install the temporary file in the real
location to allow the real location to be a symlink to a writable
directory such as /var/run (where the file actually belongs).
MFC After: 5 days