of the code in the kernel properly checks for read-onlyness before
writing into an mbuf data area. When that code is fixed, the m_dup()
can go back to being m_copypacket().
Requested by: nsayer
include:
* Mutual exclusion is used instead of spl*(). See mutex(9). (Note: The
alpha port is still in transition and currently uses both.)
* Per-CPU idle processes.
* Interrupts are run in their own separate kernel threads and can be
preempted (i386 only).
Partially contributed by: BSDi (BSD/OS)
Submissions by (at least): cp, dfr, dillon, grog, jake, jhb, sheldonh
control field compression. The ng_ppp(4) node correctly follows this
rule. However, PPPoE is an exception: when doing PPPoE *all* frames
are sent with address and control field compression.
Alter this node's behavior so that when an outgoing frame is received,
any leading address and control field bytes are removed. This makes
this node compatible with ng_ppp(4).
- It's worthwhile to use untimeout(9), even though we must still protect
against "false" timeouts, because most of the time it saves having to
handle a dummy timeout event.
- Slight tweaks to the delayed ACK algorithm paramters.
- Fix slowness when operating over fast connections, where the timeout(9)
granularity is on the same order of magnitude as the round trip time.
timeout(9) can happen up to 1 tick early, which was causing receive
ack timeouts to happen too early, causing bogus "lost" packets.
- Increase the local time counter to 64 bits to avoid roll-over.
- Keep statistics on memory allocation failures.
- Add a new option to always include the ack when sending data packets.
Might be useful in high packet loss situations. Might not.
otherwise, the ng_ether.ko KLD will never be unloadable after
all Ethernet interfaces are detached, as it should be, because
of the lingering extra reference.
Submitted by: "Yevmenkin, Maksim N, CSCIO" <myevmenkin@att.com>
netgraph. Eventually we may need to have a separate hook for packets
that already have a source AMC address but for now just drop it in.
Should fix PPPoE.
instead of bumping the recvAck counter by one, pretend that
all outstanding xmit packets are acknowleged, and restart
transmitting anew, with an empty (but halved) transmit window.
Put a lower bound on the adaptive timeout value.
This means 'options NETGRAPH' is no longer necessary in order to get
netgraph-enabled Ethernet interfaces. This supports loading/unloading
the ng_ether.ko and attaching/detaching the Ethernet interface in any
order.
Add two new hooks 'upper' and 'lower' to allow access to the protocol
demux engine and the raw device, respectively. This enables bridging
to be defined as a netgraph node, if so desired.
Reviewed by: freebsd-net@freebsd.org
world seems to interpret the spec this way
- Initialize transmit window to two instead of one; helps get things
going initially when the first packet may get dropped
- Really fix the shutdown + timeout race condition this time