still exists as a zombie. The 'kill -0' test in this function can
therefore return true even if the process isn't actually running.
This could lead to wait_for_pids() printing an endless string of the
pid number until the zombie finally exits.
Solve this problem by moving the sleep up to after the 'kill -0' test, but
only after we've run through the function once already. In the common case
(only one pid in the list) this will always do the right thing. On the rare
occasion that there is more than one pid in the list this will sleep 1
second per zombie process which will allow that process, and any other
in the list a chance to exit.
While I'm here, local'ize the variables that this function uses.
This waits for the requested process(es) to terminate, rather than polling
with an interval of 2 seconds.
If pwait is not available, the old method is used.
PR: conf/132766
Reviewed by: dougb
employ a more generic solution, and use it in the individual rc.d scripts
that also have an $rc_quiet test:
1. Add check_startmsgs() to rc.subr.
2. In the rc.d scripts that use rc_quiet (and rc.subr) substitute
variations of [ -z "$rc_quiet" ] with check_startmsgs
3. In savecore add a trailing '.' to the end of the message to make it
more consistent with other scripts.
4. In newsyslog remove a : before the terminal '.' since we do not expect
there to be anything printed out in between to make it more consistent.
5. In the following scripts change "quotes" to 'quotes' where no variables
exist in the message: savecore pf newsyslog
6. In the following scripts substitute if/then/fi for the simpler (and
more consistent) check_startmsgs &&: faith stf
7. In the following scripts separate the "Starting foo:" from the terminal
'.' to make them more consistent: moused hostname pf
8. In nfsclient move the message to its own line to avoid a style bug
9. In pf rc_quiet does not apply to the _stop method, so remove the
test there.
10. In motd add 'quotes' around the terminal '.' for consistency
and $desc.
The set_rcvar_obsolete() is for displaying an obsolete variable
and the new one. More specifically, a warning is displayed when
a variable is removed or changed in the source tree and the user
still defines the old one.
$router* and $ipv6_router* are replaced with $routed_* and
$route6d_* for consistency. The old variables still work but
can be removed in the future.
MFC after: 3 days
service behind $rc_quiet. Instead, output a warning if the pre-command
routine or the command itself failed. Arguably, it's more useful to know when
a command failed to start than it is to have an endless list of
"Starting ...." lines[1].
[1] - This change actually helped me to discover a bug in rc.d/{lockd,statd}
(fixed in r179941) that used to fail silently before.
out because the rc.conf(5) variable was not enabled. Display a
message that the command wasn't run and offer suggestions on
what the user can do.
Implement a quiet prefix, which will disable some diagnostics. The
fast prefix also implies quiet. During boot we use either fast or
quiet. For shutdown we already use 'faststop'. So, this informational
message should only appear during interactive use.
An additional benefit of having a quiet prefix is that we can start
putting some of our diagnostic messages behind this knob and start
"de-cluttering" the console during boot and shutdown.
during boot and shutdown. I think I'll hide it behind autoboot or
maybe take brooks@ suggestion and implement a different command
prefix for booting/shutdown purposes, but in any case it needs more
thought and attention.
Noticed by: ceri
Pointyhat to: mtm
for pre-5.0 variable names.
Remove two dhcp compatibility variables added after the 5.1-RELEASE.
Remove the now-unused support for these shims.
Approved by: re (kensmith)
when figuring out what the real interpreter is for an
interpreted command. That is, check whether we can read
the script file in the first place and, if so, make sure
we got a valid shebang line from it.
scripts in rc.d to stop rc(8) from booting into multi-user mode when
a critical or severe error condition is encountered.
o Modify scripts in etc/rc.d that already implemented this functionality
independently.
o Document it.
[1] - This subroutine was implemented in FreeBSD in rc.d/fsck. I moved it
to rc.subr(8). Our version differs slightly in that it takes an
optional argument to stop the boot even if "autoboot" is not set.
Obtained from: NetBSD
MFC after: 2 weeks
insert a slash between ${_chroot} and the pathname if and only if
${_chroot} is set to a non-empty string. Now the pathname is very
likely to be absolute, but we shouldn't take that for granted.
interpreted $command. Some "portable" sofware packages use such a
line to skip the task of figuring out the absolute pathname of the
interpreter at install time, e.g.:
#!/usr/bin/env python
It is insecure, but a popular book on Python seems to have advised
it to a wide audience. Hence a number of such scripts in the ports,
mostly written in Python.
PR: bin/100287
MFC after: 1 week
Implement the checks for required_* objects as two functions, one
to be run before precmd and the other after it. They get the current
rc command as an argument so they can choose what requirement tests
to perform. As of now, only "start" needs such tests.
Implement a new requirement variable, required_modules. It can
list kernel modules that need to be loaded after start_precmd
indicated success. Each name in the list can be just "file", or
"file:module", or "file~regex". This will allow us to remove a lot
of duplicated code from rc.d scripts.
Perform the checks not only for the default start method, but for
any method. This allows for more flexibility and fixes a few rc.d
scripts (namely newsyslog, pf, sendmail) that rely on a required_*
variable while providing a non-default start method.
To be able to call the new check_required* functions naturally,
remove lots of crufty duplicated code pieces from run_rc_command
and replace each of them by a call to the helper function providing
a single corrected instance of the respective code snippet. Now
run_rc_command isn't as scary as it used to be, and it even appears
to have quite a nice logic that was obscured by the old crufty code.
In the default handler for restart, run start from a subshell to
protect global varibles, e.g., _postcmd, from modification by the
start handler. This enables using restart_postcmd. [x]
PR: conf/98734 [x]
Submitted by: Rick van der Zwet <rick@wzoeterwoude.net> [x]
Reviewed by: freebsd-rc (silence for an older version)
MFC after: 1 month
There's no dollar use in variable assignment in sh.
Assuming this is can be expected behavior for some
people, this change won't be MFC'ed to RELENG_6.
Discussed with: yar on -rc
certain conditions. I haven't been able to find a better solution yet:
- Set a two read-only variables (${prefix} and ${etcdir}). This is
especially useful when using /etc/rc.d scripts with third-party
software installed from ports.
- Fix rc.d/sshd to work with openssh from ports using ${etcdir}
instead of hardcoded /etc.
- Reflect prefix/etcdir changes in rc.subr.8.
src/etc/rc.d/sshd: rev 1.9 -> 1.10
src/etc/rc.subr: rev 1.51 -> 1.52
src/share/man/man8/rc.subr.8: rev 1.11 -> 1.12
Approved by: cperciva (mentor)
it limits the width of its output to the value of $COLUMNS, or
what TIOCGWINSZ reports, or 79 columns. We should specify -ww
to ps(1) so that it removes the limit and prints lines in full.
Otherwise very long command pathnames could be mishandled, e.g.,
by _find_processes().
MFC after: 1 week
The order in _doit must be "nice su", not "su nice", for that.
In addition, don't ignore the exit status from "cd $foo_chdir".
Reviewed by: freebsd-rc (silence)
MFC after: 1 week
of them do that conditionally depending on kldstat. The code is
duplicated all over, but bugs can be uniqie.
To make the things more consistent, introduce a new rc.subr function,
load_kld, which takes care of loading a kernel module conditionally.
(Found this lying for a while in my p4 branch for various hacks.)
scripts. These scripts handle vnode backed md(4) devices.
Old ramdisk{,-own} scripts will stay a bit in CVS to allow some time for
migration since variable names have changed (ramdisk_* -> mdconfig_*).
Two new variables have been introduced to be able to populate the md(4)
device once it has been mounted (mdconfig_*_files and mdconfig_*_cmd).
Use should be as easy as:
mdconfig_md0="-t malloc -s 10m"
mdconfig_md1="-t vnode -f /var/foo.img"
See rc.conf(5) for more information and description of the additional
variables.
Approved by: cperciva
- Sync with latest version from NetBSD.
'In order to handle some perl scripts running as daemons, add a
pattern which also matches "`basename $interpreter`: $command" in the
ps listing.'
Approved by: cperciva (mentor)
Obtained from: NetBSD
MFC after: 1 week
especially useful when using /etc/rc.d scripts with third-party
software installed from ports.
- Fix rc.d/sshd to work with openssh from ports using ${etcdir}
instead of hardcoded /etc.
Reviewed by: brooks
Approved by: cperciva (mentor)
MFC after: 1 week