.\" .\" Copyright (c) 1997, 1999 Hellmuth Michaelis. All rights reserved. .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE .\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF .\" SUCH DAMAGE. .\" .\" $Id: isdnd.8,v 1.25 1999/05/20 13:30:36 hm Exp $ .\" .\" last edit-date: [Thu May 20 14:37:42 1999] .\" .Dd February 23, 1999 .Dt isdnd 8 .Sh NAME .Nm isdnd .Nd isdn4bsd ISDN connection management daemon .Sh SYNOPSIS .Nm isdnd .Op Fl c Ar configfile .Op Fl d Ar debuglevel .Op Fl f .Op Fl F .Op Fl l .Op Fl L Ar logfile .Op Fl P .Op Fl r Ar device .Op Fl s Ar facility .Op Fl t Ar terminaltype .Op Fl u Ar charging unit length .Op Fl m .Sh DESCRIPTION .Nm Isdnd is the isdn4bsd package demon which manages all ISDN related connection and disconnection of ISDN devices supported by the package. .Pp The options are as follows: .Bl -tag -width Ds .It Fl c Use .Ar configfile as the name of the runtime configuration filename for .Nm isdnd instead of the default file .Li /etc/isdn/isdnd.rc . .It Fl d If debugging support is compiled into .Nm isdnd this option is used to specify the debugging level, or better which kind of debugging messages are displayed. The debugging level is the sum of the following values: .Pp .Bl -tag -width Ds -compact -offset indent .It Ar 0x001 general debugging. .It Ar 0x002 rates calculation. .It Ar 0x004 timing calculations. .It Ar 0x008 state transitions. .It Ar 0x010 retry handling. .It Ar 0x020 dialing. .It Ar 0x040 process handling. .It Ar 0x080 isdn4bsd kernel i/o calls. .It Ar 0x100 controller and channel busy/free messages. .It Ar 0x200 isdnd.rc configuration file processing. .El .Pp The value can be specified in any number base supported by the .Xr sscanf 3 library routine. .Pp In addition, this option accepts also the character 'n' as an argument to disable displaying debug messages on the full-screen display. .Pp .It Fl f Specifying this option causes .Nm isdnd to enter the full-screen mode of operation. When operating in this mode, entering the control character .Em Control-L causes the display to be refreshed and entering .Em Carriage-Return or .Em Enter will pop-up a command window. Because the .Nm daemon will not listen to messages while the command window is active, this command window will disappear automatically after 5 seconds without any command key press. .Pp While the command window is active, .Em Tab or .Em Space advances to the next menu item. To execute a command, press .Em Return or .Em Enter for the highlighted menu item, or enter the number corresponding to the item to be executed or enter the capitalized character in the menu item description. .It Fl l If this option is set, logging is not done via the .Xr syslogd 8 facility but instead is appended to a file. .It Fl L Specifies the name of the logfile which is used when the option .Em -l is set. See also the keyword .Em rotatesuffix in the system section of .Xr isdnd.rc 5 . .It Fl P This option prints out the parsed and verified isdnd configuration in the same format as the isdnd.rc file. This output can be used as an isdnd.rc file. This feature is especially useful when debugging an isdnd.rc file to see, what the default settings of options are when they are not set in the isdnd.rc input file. .Pp The .Nm exits after the printout is done. .It Fl F This option prevents .Nm isdnd to detach from the controlling tty and become a daemon. .It Fl r In conjunction with the .Fl t option, .Ar device specifies a terminal device which becomes the controlling tty for .Nm isdnd and on which the full-screen mode output is displayed. .It Fl s This option may be used to specify the logging facility in case .Xr syslog 3 logging is configured and another facility than the default LOCAL0 facility shall be used. The facility is to be specified as an integer in the range 0-11 or 16-23 (see the file /usr/include/syslog.h). .It Fl t In conjunction with the .Fl f and .Fl r options, .Ar terminaltype specifies a terminal type or termcap entry name (such as vt220) for the device used for .Nm isdnd full-screen output. This is useful if an unused (no getty running) tty line is used for full-screen output for which no .Li TERM environment variable exists. .It Fl u Specifies the length of a charging unit in case the config file entry keyword .Em unitlenghtsrc is set to .Em cmdl . .It Fl m If the isdn daemon is compiled with local or remote monitoring support, this option disables all monitoring access. It overrides the config file option .Em monitor-allowed . .El .Pp .Sh INTERACTION WITH THE KERNEL .Nm Isdnd communicates with the kernel part of isdn4bsd by receiving status and event messages ( .Xr read 2 from device /dev/i4b ) and by transmitting commands and responses ( .Xr ioctl 2 from device /dev/i4b ). .Pp The messages and message parameters are documented in the include file .Em /usr/include/machine/i4b_ioctl.h . .Pp Supported command and response messages (ioctl's) to the kernel are: .Bl -tag -width Ds -compact -offset indent .It Ar I4B_CDID_REQ Request a unique Call Description IDentifier (cdid) which identifies uniquely a single interaction of the local D channel with the exchange. .It Ar I4B_CONNECT_REQ Actively request a call setup to a remote ISDN subscriber. .It Ar I4B_CONNECT_RESP Respond to an incoming call, either accept, reject or ignore it. .It Ar I4B_DISCONNECT_REQ Actively terminate a connection. .It Ar I4B_CTRL_INFO_REQ Request information about an installed ISDN controller card. .It Ar I4B_DIALOUT_RESP Give information about call setup to driver who requested dialing out. .It Ar I4B_TIMEOUT_UPD Update the kernels timeout value(s) in case of dynamically calculated shorthold mode timing changes. .It Ar I4B_UPDOWN_IND Inform the kernel userland drivers about interface soft up/down status changes. .It Ar I4B_CTRL_DOWNLOAD Download firmware to active card(s). .It Ar I4B_ACTIVE_DIAGNOSTIC Return diagnostic information from active cards. .El .Pp .Pp Supported status and event messages from the kernel are: .Bl -tag -width Ds -compact -offset indent .It Ar MSG_CONNECT_IND An incoming call from a remote ISDN user is indicated. .It Ar MSG_CONNECT_ACTIVE_IND After an incoming call has been accepted locally or an outgoing call has been accepted by a remote, the exchange signaled an active connection and the corresponding B-channel is switched through. .It Ar MSG_DISCONNECT_IND A call was terminated. .It Ar MSG_DIALOUT_IND A userland interface driver requests the daemon to dial out (typically a network interface when a packet arrives in its send queue). .It Ar MSG_IDLE_TIMEOUT_IND A call was terminated by the isdn4bsd kernel driver because a B-channel idle timeout occurred. .It Ar MSG_ACCT_IND Accounting information from a network driver. .It Ar MSG_CHARGING_IND Charging information from the kernel. .El .Pp .Ss OUTGOING CALLS Currently the only possibility to trigger an outgoing call is that an isdn4bsd network driver .Em (ipr) sends a .Em MSG_DIALOUT_IND to the .Nm daemon. .Pp The daemon requests a new CDID from the kernel by using the .Em I4B_CDID_REQ ioctl message, this CDID is now used in all interactions with the kernel to identify this single call until a disconnect occurs. .Pp After getting the CDID, the daemon looks up several additional information in its entry section of the configuration corresponding to that connection and issues a .Em I4B_CONNECT_REQ ioctl message to the kernel. The kernel now dials the remote side and if the remote side accepts the call, the kernel sends a .Em MSG_CONNECT_ACTIVE_IND to the daemon. .Pp The call is terminated by either the local site timing out or the remote side hanging up the connection or the local side actively sending a .Em I4B_DISCONNECT_REQ ioctl message, both events are signaled to the .Nm by the kernel sending the .Em I4B_DISCONNECT_IND message and the CDID corresponding to the call is no longer valid. .Pp .Ss INCOMING CALLS Incoming calls are signaled to the .Nm by the kernel transmitting the .Em MSG_CONNECT_IND message to the daemon. .Pp With the information contained in this message, the .Nm searches the entry section of its configuration database and if a match is found, it accepts or rejects the call or, if no match is found, it ignores the call - all by issuing a .Em I4B_CONNECT_RESP ioctl message with the appropriate parameters to the kernel. .Pp In case the daemon decided to accept the call, the kernel signals this by sending a .Em MSG_CONNECT_ACTIVE_IND message to the daemon. .Pp The call is terminated by either the local site timing out or the remote side hanging up the connection or the local side actively sending a .Em I4B_DISCONNECT_REQ ioctl message, both events are signaled to the .Nm by the kernel sending the .Em I4B_DISCONNECT_IND message and the CDID corresponding to the call is no longer valid. .Pp .Sh SIGNALS Sending a HUP signal to .Nm causes all open connections to be terminated and the configuration file is reread. In case aliasfile handling was enabled, the aliasfile is also reread. Sending a USR1 signal to .Nm causes the accounting file and the logfile (if logging to a file is used instead of logging via the .Xr syslog 3 facility) to be closed and reopened to make logfile rotation possible. .Sh ENVIRONMENT The following environment variables affect the execution of .Nm isdnd : .Bl -tag -width Ds .It Ev TERM The terminal type when running in full-screen display mode. See .Xr environ 7 for more information. .El .Sh FILES .Bl -tag -width /etc/isdn/isdnd.rates -compact .It Pa /dev/i4b The device-file used to communicate with the kernel ISDN driver subsystem. .It Pa /var/log/messages A record of the actions in case of syslogd logging support. .It Pa /var/log/isdnd.acct The default accounting information filename (if accounting is configured). .It Pa /var/log/isdnd.log The default logging filename (if logging to a file is configured). .It Pa /var/run/isdnd.pid The process id of the isdn daemon (also known as "lockfile" to isdnd, preventing multiple invocations of it). .It Pa /usr/local/lib/isdn .It Pa /etc/isdn The directory where isdnd expects some supplementary data files and programs for telephone answering support. .It Pa /etc/isdn/isdnd.rc The default runtime configuration file. .It Pa /etc/isdn/isdnd.rates The default unit charging rates specification file. .It Pa /etc/isdn/isdntel.alias The default table (if aliasing is enabled) to convert phone number to caller's name. .El .Sh EXAMPLES For a first try, the following command should be used to start .Nm in foreground mode for better debugging the configuration setup: .Bd -literal -offset indent isdnd -d0xf9 -F .Ed .Pp This will start isdnd with reasonable debugging settings and produce output on the current terminal. .Nm Isdnd can then be terminated by entering Control-C. .Pp Another example, the command: .Bd -literal -offset indent isdnd -d0xf9 -f -r /dev/ttyv3 -t vt100 .Ed .Pp will start .Nm isdnd with reasonable debugging messages enabled, full-screen mode of operation, full-screen display redirected to /dev/ttyv03 and using a termcap entry for vt100 on this display. .Sh DIAGNOSTICS Exit status is 0 on success, 1 on error. .Pp .Sh SEE ALSO .Xr syslogd 8 , .Xr isdntrace 8 , .Xr isdntel 8 , .Xr isdnd.rc 5 , .Xr isdnd.rates 5 , .Xr i4bisppp 4 , .Xr i4bipr 4 .Sh BUGS Still one or more left. .Sh AUTHOR The .Nm daemon and this manual page were written by Hellmuth Michaelis. He can be contacted at hm@kts.org or hm@hcs.de.