.\" .\" Copyright (c) 2008 Yahoo!, Inc. .\" All rights reserved. .\" Written by: John Baldwin .\" .\" Redistribution and use in source and binary forms, with or without .\" modification, are permitted provided that the following conditions .\" are met: .\" 1. Redistributions of source code must retain the above copyright .\" notice, this list of conditions and the following disclaimer. .\" 2. Redistributions in binary form must reproduce the above copyright .\" notice, this list of conditions and the following disclaimer in the .\" documentation and/or other materials provided with the distribution. .\" 3. Neither the name of the author nor the names of any co-contributors .\" may be used to endorse or promote products derived from this software .\" without specific prior written permission. .\" .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE .\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF .\" SUCH DAMAGE. .\" .\" $FreeBSD$ .\" .Dd August 16, 2009 .Dt MPTUTIL 8 .Os .Sh NAME .Nm mptutil .Nd Utility for managing LSI Fusion-MPT controllers .Sh SYNOPSIS .Nm .Cm version .Nm .Op Fl u Ar unit .Cm show adapter .Nm .Op Fl u Ar unit .Cm show config .Nm .Op Fl u Ar unit .Cm show drives .Nm .Op Fl u Ar unit .Cm show events .Nm .Op Fl u Ar unit .Cm show volumes .Nm .Op Fl u Ar unit .Cm fail Ar drive .Nm .Op Fl u Ar unit .Cm online Ar drive .Nm .Op Fl u Ar unit .Cm offline Ar drive .Nm .Op Fl u Ar unit .Cm name Ar volume Ar name .Nm .Op Fl u Ar unit .Cm volume status Ar volume .Nm .Op Fl u Ar unit .Cm volume cache Ar volume .Ar enable|disable .Nm .Op Fl u Ar unit .Cm clear .Nm .Op Fl u Ar unit .Cm create Ar type .Op Fl q .Op Fl v .Op Fl s Ar stripe_size .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..." .Nm .Op Fl u Ar unit .Cm delete Ar volume .Nm .Op Fl u Ar unit .Cm add Ar drive Op Ar volume .Nm .Op Fl u Ar unit .Cm remove Ar drive .Sh DESCRIPTION The .Nm utility can be used to display or modify various parameters on LSI Fusion-MPT controllers. Each invocation of .Nm consists of zero or more global options followed by a command. Commands may support additional optional or required arguments after the command. .Pp Currently one global option is supported: .Bl -tag -width indent .It Fl u Ar unit .Ar unit specifies the unit of the controller to work with. If no unit is specified, then unit 0 is used. .El .Pp Volumes may be specified in two forms. First, a volume may be identified by its location as .Sm off .Op Ar xx Ns \&: .Ar yy .Sm on where .Ar xx is the bus ID and .Ar yy is the target ID. If the bus ID is ommitted, the volume is assumed to be on bus 0. Second, on the volume may be specified by the corresponding .Em daX device, such as .Em da0 . .Pp The .Xr mpt 4 controller divides drives up into two categories. Configured drives belong to a RAID volume either as a member drive or as a hot spare. Each configured drive is assigned a unique device ID such as 0 or 1 that is show in .Cm show config , and in the first column of .Cm show drives . Any drive not associated with a RAID volume as either a member or a hot spare is a standalone drive. Standalone drives are visible to the operating system as SCSI disk devices. As a result, drives may be specified in three forms. First, a configured drive may be identified by its device ID. Second, any drive may be identified by its location as .Sm off .Ar xx Ns \&: .Ar yy .Sm on where .Ar xx is the bus ID and .Ar yy is the target ID for each drive as displayed in .Cm show drives . Note that unlike volumes, a drive location always requires the bus ID to avoid confusion with device IDs. Third, a standalone drive that is not part of a volume may be identified by its corresponding .Em daX device as displayed in .Cm show drives . .Pp The .Nm utility supports several different groups of commands. The first group of commands provide information about the controller, the volumes it manages, and the drives it controls. The second group of commands are used to manage the physical drives attached to the controller. The third group of commands are used to manage the logical volumes managed by the controller. The fourth group of commands are used to manage the drive configuration for the controller. .Pp The informational commands include: .Bl -tag -width indent .It Cm version Displays the version of .Nm . .It Cm show adapter Displays information about the RAID controller such as the model number. .It Cm show config Displays the volume and drive configuration for the controller. Each volume is listed along with the physical drives that the volume spans. If any hot spare drives are configured, then they are listed as well. .It Cm show drives Lists all of the physical drives attached to the controller. .It Cm show events Display all the entries from the controller's event log. Due to lack of documentation this command isn't very useful currently and just dumps each log entry in hex. .It Cm show volumes Lists all of the logical volumes managed by the controller. .El .Pp The physical drive management commands include: .Bl -tag -width indent .It Cm fail Ar drive Mark .Ar drive as .Dq failed requested . Note that this state is different from the .Dq failed state that is used when the firmware fails a drive. .Ar Drive must be a configured drive. .It Cm online Ar drive Mark .Ar drive as an online drive. .Ar Drive must be part a configured drive in either the .Dq offline or .Dq failed requested states. .It Cm offline Ar drive Mark .Ar drive as offline. .Ar Drive must be a configured, online drive. .El .Pp The logical volume management commands include: .Bl -tag -width indent .It Cm name Ar volume Ar name Sets the name of .Ar volume to .Ar name . .It Cm volume cache Ar volume Ar enable|disable Enables or disables the drive write cache for the member drives of .Ar volume . .It Cm volume status Ar volume Display more detailed status about a single volume including the current progress of a rebuild operation if one is being performed. .El .Pp The configuration commands include: .Bl -tag -width indent .It Cm clear Delete the entire configuration including all volumes and spares. All drives will become standalone drives. .It Xo Cm create Ar type .Op Fl q .Op Fl v .Op Fl s Ar stripe_size .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..." .Xc Create a new volume. The .Ar type specifies the type of volume to create. Currently supported types include: .Bl -tag -width indent .It Cm raid0 Creates one RAID0 volume spanning the drives listed in the single drive list. .It Cm raid1 Creates one RAID1 volume spanning the drives listed in the single drive list. .It Cm raid1e Creates one RAID1E volume spanning the drives listed in the single drive list. .El .Pp .Sy Note: Not all volume types are supported by all controllers. .Pp If the .Fl q flag is specified after .Ar type , then a .Dq quick initialization of the volume will be done. This is useful when the drives do not contain any existing data that need to be preserved. .Pp If the .Fl v flag is specified after .Ar type , then more verbose output will be enabled. Currently this just provides notification as drives are added to volumes when building the configuration. .Pp The .Fl s .Ar stripe_size parameter allows the stripe size of the array to be set. By default a stripe size of 64K is used. The list of valid values for a given .Ar type are listed in the output of .Cm show adapter . .It Cm delete Ar volume Delete the volume .Ar volume . Member drives will become standalone drives. .It Cm add Ar drive Op Ar volume Mark .Ar drive as a hot spare. .Ar Drive must not be a member of a volume. If .Ar volume is specified, then the hot spare will be dedicated to that volume. Otherwise, .Ar drive will be used as a global hot spare backing all volumes for this controller. Note that .Ar drive must be as large as the smallest drive in all of the volumes it is going to back. .It Cm remove Ar drive Remove the hot spare .Ar drive from service. It will become a standalone drive. .El .Sh EXAMPLES Mark the drive at bus 0 target 4 as offline: .Pp .Dl Nm Cm offline 0:4 .Pp Create a RAID1 array from the two standalone drives .Va da1 and .Va da2 : .Pp .Dl Nm Cm create raid1 da1,da2 .Pp Mark standalone drive .Va da3 as a global hot spare: .Pp .Dl Nm Cm add da3 .Sh SEE ALSO .Xr mpt 4 .Sh HISTORY The .Nm utility first appeared in .Fx 8.0 . .Sh BUGS .Pp The handling of spare drives appears to be unreliable. The .Xr mpt 4 firmware manages spares via spare drive .Dq pools . There are eight pools numbered 0 through 7. Each spare drive can only be assigned to a single pool. Each volume can be backed by any combination of zero or more spare pools. The .Nm utility attempts to use the following algorithm for managing spares. Global spares are always assigned to pool 0, and all volumes are always backed by pool 0. For dedicated spares, .Nm assigns one of the remaining 7 pools to each volume and assigns dedicated drives to that pool. In practice however, it seems that assigning a drive as a spare does not take effect until the box has been rebooted. Also, the firmware renumbers the spare pool assignments after a reboot which undoes the effects of the algorithm above. Simple cases such as assigning global spares seem to work ok .Pq albeit requiring a reboot to take effect but more .Dq exotic configurations may not work reliably. .Pp Drive configuration commands result in an excessive flood of messages on the console. .Pp The mpt version 1 API that is used by .Nm and .Xr mpt 4 doesn't support volumes above two terabytes. This is a limitation of the API. If you are using this adapter with volumes larger than two terabytes, use the adapter in JBOD mode. Utilize .Xr geom 8 , .Xr zfs 8 , or another software volume manager to work around this limitation.