Ryan Libby 64e0efab39 db show thread: avoid overflow in tick conversion
The previous calculations for displaying the time since last switch
easily overflowed, after less than 36 min for hz=1000.  Now overflow
takes 2000 times longer (as long as ticks takes to wrap).

Reviewed by:	cem, markj
Sponsored by:	Dell EMC Isilon
Differential revision:	https://reviews.freebsd.org/D20273
2019-05-16 05:29:54 +00:00
..
2017-11-30 15:58:38 +00:00
2018-10-20 20:45:49 +00:00
2018-05-10 03:59:48 +00:00
2018-01-08 21:27:41 +00:00
2018-10-20 20:45:49 +00:00
2018-05-10 03:59:48 +00:00