Change usb devd events from fake attach to a notify. The ugen device is not a proper device_t so it faked the devctl event to appear like one, this is now a notify which allows more information to be passed. We notify for both the device attach/detach and for each usb interface. A devd rule can now match on the interface properties, including composite devices which may have a uvideo interface and also usound and possibly uhid too. An example to match a umass device with a scsi subclass and BBB protocol would be notify 100 { match "system" "USB"; match "subsystem" "INTERFACE"; match "type" "ATTACH"; match "intclass" "0x08"; match "intsubclass" "0x06"; match "intprotocol" "0x50"; action ... }; The old attach devctl event has been retained for the moment to make merging to 8.1 easier. This was never compatible with 7.x or earlier due to the ugen regex change needed. Document the new USB notification types.
543 lines
14 KiB
Groff
543 lines
14 KiB
Groff
.\"
|
|
.\" Copyright (c) 2002 M. Warner Losh
|
|
.\" All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. The name of the author may not be used to endorse or promote products
|
|
.\" derived from this software without specific prior written permission.
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
|
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
.\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
|
|
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
.\" SUCH DAMAGE.
|
|
.\"
|
|
.\" $FreeBSD$
|
|
.\"
|
|
.\" The section on comments was taken from named.conf.5, which has the
|
|
.\" following copyright:
|
|
.\" Copyright (c) 1999-2000 by Internet Software Consortium
|
|
.\"
|
|
.\" Permission to use, copy, modify, and distribute this software for any
|
|
.\" purpose with or without fee is hereby granted, provided that the above
|
|
.\" copyright notice and this permission notice appear in all copies.
|
|
.\"
|
|
.\" THE SOFTWARE IS PROVIDED "AS IS" AND INTERNET SOFTWARE CONSORTIUM DISCLAIMS
|
|
.\" ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES
|
|
.\" OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL INTERNET SOFTWARE
|
|
.\" CONSORTIUM BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL
|
|
.\" DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR
|
|
.\" PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS
|
|
.\" ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS
|
|
.\" SOFTWARE.
|
|
.\"
|
|
.Dd March 8, 2009
|
|
.Dt DEVD.CONF 5
|
|
.Os
|
|
.Sh NAME
|
|
.Nm devd.conf
|
|
.Nd configuration file for
|
|
.Xr devd 8
|
|
.Sh DESCRIPTION
|
|
.Ss General Syntax
|
|
A
|
|
.Xr devd 8
|
|
configuration consists of two general features, statements
|
|
and comments.
|
|
All statements end with a semicolon.
|
|
Many statements can contain substatements, which are also
|
|
terminated with a semicolon.
|
|
.Pp
|
|
The following statements are supported:
|
|
.Bl -tag -width ".Ic options"
|
|
.It Ic attach
|
|
Specifies various matching criteria and actions to perform when
|
|
a newly attached device matches said criteria.
|
|
.It Ic detach
|
|
Specifies various matching criteria and actions to perform when
|
|
a newly detached device matches said criteria.
|
|
.It Ic nomatch
|
|
Specifies various matching criteria and actions to perform when
|
|
no device driver currently loaded in the kernel claims a (new)
|
|
device.
|
|
.It Ic notify
|
|
Specifies various matching criteria and actions to perform when the kernel
|
|
sends an event notification to userland.
|
|
.It Ic options
|
|
Specifies various options and parameters for the operation of
|
|
.Xr devd 8 .
|
|
.El
|
|
.Pp
|
|
Statements may occur in any order in the configuration file, and may be
|
|
repeated as often as required.
|
|
Further details on the syntax and meaning of each statement and their
|
|
substatements are explained below.
|
|
.Pp
|
|
Each statement, except
|
|
.Ic options
|
|
has a priority (an arbitrary number) associated with it, where
|
|
.Ql 0
|
|
is defined as the lowest priority.
|
|
If two statements match the same event, only the action of the statement with
|
|
highest priority will be executed.
|
|
In this way generic statements can be overridden for devices or
|
|
notifications that require special attention.
|
|
.Pp
|
|
The general syntax of a statement is:
|
|
.Pp
|
|
.Bd -literal -offset indent
|
|
statement priority {
|
|
substatement "value";
|
|
...
|
|
substatement "value";
|
|
};
|
|
.Ed
|
|
.Ss Sub-statements
|
|
The following sub-statements are supported within the
|
|
.Ic options
|
|
statement.
|
|
.Bl -tag -width ".Ic directory"
|
|
.It Ic directory Qq Ar /some/path ;
|
|
Adds the given directory to the list of directories from which
|
|
.Xr devd 8
|
|
will read all files named "*.conf" as further
|
|
configuration files.
|
|
Any number of
|
|
.Ic directory
|
|
statements can be used.
|
|
.It Ic pid-file Qq Pa /var/run/devd.pid ;
|
|
Specifies PID file.
|
|
.It Ic set Ar regexp-name Qq Ar (some|regexp) ;
|
|
Creates a regular expression and assigns it to the variable
|
|
.Ar regexp-name .
|
|
The variable is available throughout the rest of
|
|
the configuration file.
|
|
All regular expressions have an implicit
|
|
.Ql ^$
|
|
around them.
|
|
.El
|
|
.Pp
|
|
The following sub-statements are supported within the
|
|
.Ic attach
|
|
and
|
|
.Ic detach
|
|
statements.
|
|
.Bl -tag -width ".Ic directory"
|
|
.It Ic action Qq Ar command ;
|
|
Command to execute upon a successful match.
|
|
Example
|
|
.Dq Li "/etc/pccard_ether $device-name start" .
|
|
.It Ic class Qq Ar string ;
|
|
This is shorthand for
|
|
.Dq Ic match Qo Li class Qc Qq Ar string .
|
|
.It Ic device-name Qq string ;
|
|
This is shorthand for
|
|
.Dq Ic match Qo Li device-name Qc Qq Ar string .
|
|
This matches a device named
|
|
.Ar string ,
|
|
which is allowed to be a regular expression or a variable previously created
|
|
containing a regular expression.
|
|
The
|
|
.Dq Li device-name
|
|
variable
|
|
is available for later use with the
|
|
.Ic action
|
|
statement.
|
|
.It Ic match Qo Ar variable Qc Qq Ar value ;
|
|
Matches the content of
|
|
.Ar value
|
|
against
|
|
.Ar variable ;
|
|
the content of
|
|
.Ar value
|
|
may be a regular expression.
|
|
Not required during
|
|
.Ic attach
|
|
nor
|
|
.Ic detach
|
|
events since the
|
|
.Ic device-name
|
|
statement takes care of all device matching.
|
|
For a partial list of variables, see below.
|
|
.It Ic media-type Qq Ar string ;
|
|
For network devices,
|
|
.Ic media-type
|
|
will match devices that have the given media type.
|
|
Valid media types are:
|
|
.Dq Li Ethernet ,
|
|
.Dq Li Tokenring ,
|
|
.Dq Li FDDI ,
|
|
.Dq Li 802.11 ,
|
|
.Dq Li ATM ,
|
|
and
|
|
.Dq Li CARP .
|
|
.It Ic subdevice Qq Ar string ;
|
|
This is shorthand for
|
|
.Dq Ic match Qo Li subdevice Qc Qq Ar string .
|
|
.El
|
|
.Pp
|
|
The following sub-statements are supported within the
|
|
.Ic nomatch
|
|
statement.
|
|
.Bl -tag -width ".Ic directory"
|
|
.It Ic action Qq Ar command ;
|
|
Same as above.
|
|
.It Ic match Qo Ar variable Qc Qq Ar value ;
|
|
Matches the content of
|
|
.Ar value
|
|
against
|
|
.Ar variable ;
|
|
the content of
|
|
.Ar value
|
|
may be a regular expression.
|
|
For a partial list of variables, see below.
|
|
.El
|
|
.Pp
|
|
The following sub-statements are supported within the
|
|
.Ic notify
|
|
statement.
|
|
The
|
|
.Dq Li notify
|
|
variable is available inside this statement and contains, a value, depending
|
|
on which system and subsystem that delivered the event.
|
|
.Bl -tag -width ".Ic directory"
|
|
.It Ic action Qq Ar command ;
|
|
Command to execute upon a successful match.
|
|
Example
|
|
.Dq Li "/etc/rc.d/power_profile $notify" .
|
|
.It Ic match Qo Ar system | subsystem | type | notify Qc Qq Ar value ;
|
|
Any number of
|
|
.Ic match
|
|
statements can exist within a
|
|
.Ic notify
|
|
statement;
|
|
.Ar value
|
|
can be either a fixed string or a regular expression.
|
|
Below is a list of available systems, subsystems, and types.
|
|
.It Ic media-type Qq Ar string ;
|
|
See above.
|
|
.El
|
|
.Ss Variables that can be used with the match statement
|
|
A partial list of variables and their possible values that can be used together
|
|
with the
|
|
.Ic match
|
|
statement.
|
|
.Pp
|
|
.Bl -tag -width ".Li manufacturer" -compact
|
|
.It Ic Variable
|
|
.Ic Description
|
|
.It Li bus
|
|
Device name of parent bus.
|
|
.It Li cdev
|
|
Device node path if one is created by the
|
|
.Xr devfs 5
|
|
filesystem.
|
|
.It Li cisproduct
|
|
CIS-product.
|
|
.It Li cisvendor
|
|
CIS-vendor.
|
|
.It Li class
|
|
Device class.
|
|
.It Li device
|
|
Device ID.
|
|
.It Li devclass
|
|
Device Class (USB)
|
|
.It Li devsubclass
|
|
Device Sub-class (USB)
|
|
.It Li device-name
|
|
Name of attached/detached device.
|
|
.It Li endpoints
|
|
Endpoint count (USB)
|
|
.It Li function
|
|
Card functions.
|
|
.It Li interface
|
|
Interface ID (USB)
|
|
.It Li intclass
|
|
Interface Class (USB)
|
|
.It Li intprotocol
|
|
Interface Protocol (USB)
|
|
.It Li intsubclass
|
|
Interface Sub-class (USB)
|
|
.It Li manufacturer
|
|
Manufacturer ID (pccard).
|
|
.It Li mode
|
|
Peripheral mode (USB)
|
|
.It Li notify
|
|
Match the value of the
|
|
.Dq Li notify
|
|
variable.
|
|
.It Li parent
|
|
Parent device
|
|
.It Li port
|
|
Hub port number (USB)
|
|
.It Li product
|
|
Product ID (pccard/USB).
|
|
.It Li release
|
|
Hardware revision (USB)
|
|
.It Li serial
|
|
Serial Number (USB).
|
|
.It Li slot
|
|
Card slot.
|
|
.It Li subvendor
|
|
Sub-vendor ID.
|
|
.It Li subdevice
|
|
Sub-device ID.
|
|
.It Li subsystem
|
|
Matches a subsystem of a system, see below.
|
|
.It Li system
|
|
Matches a system type, see below.
|
|
.It Li type
|
|
Type of notification, see below.
|
|
.It Li vendor
|
|
Vendor ID.
|
|
.El
|
|
.Ss Notify matching
|
|
A partial list of systems, subsystems, and types used within the
|
|
.Ic notify
|
|
mechanism.
|
|
.Pp
|
|
.Bl -tag -width ".Li coretemp" -compact
|
|
.It Sy System
|
|
.It Li ACPI
|
|
Events related to the ACPI subsystem.
|
|
.Bl -tag -width ".Sy Subsystem" -compact
|
|
.It Sy Subsystem
|
|
.It Li ACAD
|
|
AC line state ($notify=0x00 is offline, 0x01 is online).
|
|
.It Li Button
|
|
Button state ($notify=0x00 is power, 0x01 is sleep).
|
|
.It Li CMBAT
|
|
Battery events.
|
|
.It Li Lid
|
|
Lid state ($notify=0x00 is closed, 0x01 is open).
|
|
.It Li Thermal
|
|
Thermal zone events.
|
|
.El
|
|
.Pp
|
|
.It Li IFNET
|
|
Events related to the network subsystem.
|
|
.Bl -tag -width ".Sy Subsystem" -compact
|
|
.It Sy Subsystem
|
|
.It Ar interface
|
|
The
|
|
.Dq subsystem
|
|
is the actual name of the network interface on which the event
|
|
took place.
|
|
.Bl -tag -width ".Li LINK_DOWN" -compact
|
|
.It Sy Type
|
|
.It Li LINK_UP
|
|
Carrier status changed to UP.
|
|
.It Li LINK_DOWN
|
|
Carrier status changed to DOWN.
|
|
.It Li ATTACH
|
|
The network interface is attached to the system.
|
|
.It Li DETACH
|
|
The network interface is detached from the system.
|
|
.El
|
|
.El
|
|
.It Li DEVFS
|
|
Events related to the
|
|
.Xr devfs 5
|
|
filesystem.
|
|
.Bl -tag -width ".Sy Subsystem" -compact
|
|
.It Sy Subsystem
|
|
.It Li CDEV
|
|
.Bl -tag -width ".Li DESTROY" -compact
|
|
.It Sy Type
|
|
.It Li CREATE
|
|
The
|
|
.Xr devfs 5
|
|
node is created.
|
|
.It Li DESTROY
|
|
The
|
|
.Xr devfs 5
|
|
node is destroyed.
|
|
.El
|
|
.El
|
|
.It Li USB
|
|
Events related to the USB subsystem.
|
|
.Bl -tag -width ".Sy Subsystem" -compact
|
|
.It Sy Subsystem
|
|
.It Li DEVICE
|
|
.Bl -tag -width ".Li DETACH" -compact
|
|
.It Sy Type
|
|
.It Li ATTACH
|
|
USB device is attached to the system.
|
|
.It Li DETACH
|
|
USB device is detached from the system.
|
|
.El
|
|
.It Li INTERFACE
|
|
.Bl -tag -width ".Li DETACH" -compact
|
|
.It Sy Type
|
|
.It Li ATTACH
|
|
USB interface is attached from a device.
|
|
.It Li DETACH
|
|
USB interface is detached from a device.
|
|
.El
|
|
.El
|
|
.It Li coretemp
|
|
Events related to the
|
|
.Xr coretemp 4
|
|
device.
|
|
.Bl -tag -width ".Sy Subsystem" -compact
|
|
.It Sy Subsystem
|
|
.It Li Thermal
|
|
Notification that the CPU core has reached critical temperature.
|
|
.Bl -tag -width ".Ar temperature" -compact
|
|
.It Sy Type
|
|
.It Ar temperature
|
|
String containing the temperature of the core that has become too hot.
|
|
.El
|
|
.El
|
|
.It Li kern
|
|
Events related to the kernel.
|
|
.Bl -tag -width ".Sy Subsystem" -compact
|
|
.It Sy Subsystem
|
|
.It Li power
|
|
Information about the state of the system.
|
|
.Bl -tag -width ".li resume" -compact
|
|
.It Sy Type
|
|
.It Li resume
|
|
Notification that the system has woken from the suspended state.
|
|
.El
|
|
.El
|
|
.El
|
|
.Pp
|
|
A link state change to UP on the interface
|
|
.Dq Li fxp0
|
|
would result in the following notify event:
|
|
.Bd -literal -offset indent
|
|
system=IFNET, subsystem=fxp0, type=LINK_UP
|
|
.Ed
|
|
.Pp
|
|
An AC line state change to
|
|
.Dq offline
|
|
would result in the following event:
|
|
.Bd -literal -offset indent
|
|
system=ACPI, subsystem=ACAD, notify=0x00
|
|
.Ed
|
|
.Ss Comments
|
|
Comments may appear anywhere that whitespace may appear in a
|
|
configuration file.
|
|
To appeal to programmers of all kinds, they can
|
|
be written in C, C++, or shell/Perl constructs.
|
|
.Pp
|
|
C-style comments start with the two characters
|
|
.Ql /*
|
|
(slash, star) and end with
|
|
.Ql */
|
|
(star, slash).
|
|
Because they are completely delimited with these characters,
|
|
they can be used to comment only a portion of a line or to span
|
|
multiple lines.
|
|
.Pp
|
|
C-style comments cannot be nested.
|
|
For example, the following is
|
|
not valid because the entire comment ends with the first
|
|
.Ql */ :
|
|
.Bd -literal -offset indent
|
|
/* This is the start of a comment.
|
|
This is still part of the comment.
|
|
/* This is an incorrect attempt at nesting a comment. */
|
|
This is no longer in any comment. */
|
|
.Ed
|
|
.Pp
|
|
C++-style comments start with the two characters
|
|
.Ql //
|
|
(slash, slash) and continue to the end of the physical line.
|
|
They cannot be continued across multiple physical lines; to have
|
|
one logical comment span multiple lines, each line must use the
|
|
.Ql //
|
|
pair.
|
|
For example:
|
|
.Bd -literal -offset indent
|
|
// This is the start of a comment. The next line
|
|
// is a new comment, even though it is logically
|
|
// part of the previous comment.
|
|
.Ed
|
|
.Sh FILES
|
|
.Bl -tag -width ".Pa /etc/devd.conf" -compact
|
|
.It Pa /etc/devd.conf
|
|
The
|
|
.Xr devd 8
|
|
configuration file.
|
|
.El
|
|
.Sh EXAMPLES
|
|
.Bd -literal
|
|
#
|
|
# This will catch link down events on the interfaces fxp0 and ath0
|
|
#
|
|
notify 0 {
|
|
match "system" "IFNET";
|
|
match "subsystem" "(fxp0|ath0)";
|
|
match "type" "LINK_DOWN";
|
|
action "logger $subsystem is DOWN";
|
|
};
|
|
|
|
#
|
|
# Match lid open/close events
|
|
# These can be combined to a single event, by passing the
|
|
# value of $notify to the external script.
|
|
#
|
|
notify 0 {
|
|
match "system" "ACPI";
|
|
match "subsystem" "Lid";
|
|
match "notify" "0x00";
|
|
action "logger Lid closed, we can sleep now!";
|
|
};
|
|
|
|
notify 0 {
|
|
match "system" "ACPI";
|
|
match "subsystem" "Lid";
|
|
match "notify" "0x01";
|
|
action "logger Lid opened, the sleeper must awaken!";
|
|
};
|
|
|
|
#
|
|
# Match a USB device type
|
|
#
|
|
notify 0 {
|
|
match "system" "USB";
|
|
match "subsystem" "INTERFACE";
|
|
match "type" "ATTACH";
|
|
match "intclass" "0x0e";
|
|
action "logger USB video device attached";
|
|
};
|
|
|
|
#
|
|
# Try to configure ath and wi devices with pccard_ether
|
|
# as they are attached.
|
|
#
|
|
attach 0 {
|
|
device-name "(ath|wi)[0-9]+";
|
|
action "/etc/pccard_ether $device-name start";
|
|
};
|
|
|
|
#
|
|
# Stop ath and wi devices as they are detached from
|
|
# the system.
|
|
#
|
|
detach 0 {
|
|
device-name "(ath|wi)[0-9]+";
|
|
action "/etc/pccard_ether $device-name stop";
|
|
};
|
|
.Ed
|
|
.Pp
|
|
The installed
|
|
.Pa /etc/devd.conf
|
|
has many additional examples.
|
|
.Sh SEE ALSO
|
|
.Xr coretemp 4 ,
|
|
.Xr devfs 5 ,
|
|
.Xr devd 8
|