ePWM is controlled by sysctl nodes dev.am335x_pwm.N.period,
dev.am335x_pwm.N.dutyA and dev.am335x_pwm.N.dutyB that controls
PWM period and duty cycles for channels A and B respectively.
Period and duty cycle are measured in clock ticks. Default
clock frequency for AM335x PWM subsystem is 100MHz