Marcel Moolenaar 3cf09dd123 Fix an unaligned I/O memory access in the event that a SCB times out.
The FXP_SCR_FLOWCONTROL registers is at offset 0x19, but 2 bytes wide.
It cannot be read as a word without causing a panic on architectures
that enforce strict alignment.

MFC after: 3 days