* Copyright (c) 2005 Chris Jones
|
|
* All rights reserved.
|
|
*
|
|
* This software was developed for the FreeBSD Project by Chris Jones
|
|
* thanks to the support of Google's Summer of Code program and
|
|
* mentoring by Lukas Ertl.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
|
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
* ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
|
|
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
* SUCH DAMAGE.
|
|
*
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
#include <sys/param.h>
|
|
#include <sys/libkern.h>
|
|
#include <sys/kernel.h>
|
|
#include <sys/malloc.h>
|
|
|
|
#include <geom/geom.h>
|
|
#include <geom/vinum/geom_vinum_var.h>
|
|
#include <geom/vinum/geom_vinum.h>
|
|
#include <geom/vinum/geom_vinum_share.h>
|
|
|
|
static int gv_rename_drive(struct gv_softc *, struct gctl_req *,
|
|
struct gv_drive *, char *, int);
|
|
static int gv_rename_plex(struct gv_softc *, struct gctl_req *,
|
|
struct gv_plex *, char *, int);
|
|
static int gv_rename_sd(struct gv_softc *, struct gctl_req *,
|
|
struct gv_sd *, char *, int);
|
|
static int gv_rename_vol(struct gv_softc *, struct gctl_req *,
|
|
struct gv_volume *, char *, int);
|
|
|
|
void
|
|
gv_rename(struct g_geom *gp, struct gctl_req *req)
|
|
{
|
|
struct gv_softc *sc;
|
|
struct gv_volume *v;
|
|
struct gv_plex *p;
|
|
struct gv_sd *s;
|
|
struct gv_drive *d;
|
|
char *newname, *object;
|
|
int err, *flags, type;
|
|
|
|
sc = gp->softc;
|
|
|
|
flags = gctl_get_paraml(req, "flags", sizeof(*flags));
|
|
|
|
newname = gctl_get_param(req, "newname", NULL);
|
|
if (newname == NULL) {
|
|
gctl_error(req, "no new name given");
|
|
return;
|
|
}
|
|
|
|
object = gctl_get_param(req, "object", NULL);
|
|
if (object == NULL) {
|
|
gctl_error(req, "no object given");
|
|
return;
|
|
}
|
|
|
|
type = gv_object_type(sc, object);
|
|
switch (type) {
|
|
case GV_TYPE_VOL:
|
|
v = gv_find_vol(sc, object);
|
|
if (v == NULL) {
|
|
gctl_error(req, "unknown volume '%s'", object);
|
|
return;
|
|
}
|
|
err = gv_rename_vol(sc, req, v, newname, *flags);
|
|
if (err)
|
|
return;
|
|
break;
|
|
case GV_TYPE_PLEX:
|
|
p = gv_find_plex(sc, object);
|
|
if (p == NULL) {
|
|
gctl_error(req, "unknown plex '%s'", object);
|
|
return;
|
|
}
|
|
err = gv_rename_plex(sc, req, p, newname, *flags);
|
|
if (err)
|
|
return;
|
|
break;
|
|
case GV_TYPE_SD:
|
|
s = gv_find_sd(sc, object);
|
|
if (s == NULL) {
|
|
gctl_error(req, "unknown subdisk '%s'", object);
|
|
return;
|
|
}
|
|
err = gv_rename_sd(sc, req, s, newname, *flags);
|
|
if (err)
|
|
return;
|
|
break;
|
|
case GV_TYPE_DRIVE:
|
|
d = gv_find_drive(sc, object);
|
|
if (d == NULL) {
|
|
gctl_error(req, "unknown drive '%s'", object);
|
|
return;
|
|
}
|
|
err = gv_rename_drive(sc, req, d, newname, *flags);
|
|
if (err)
|
|
return;
|
|
break;
|
|
default:
|
|
gctl_error(req, "unknown object '%s'", object);
|
|
return;
|
|
}
|
|
|
|
gv_save_config_all(sc);
|
|
}
|
|
|
|
static int
|
|
gv_rename_drive(struct gv_softc *sc, struct gctl_req *req, struct gv_drive *d, char *newname, int flags)
|
|
{
|
|
struct gv_sd *s;
|
|
|
|
g_topology_assert();
|
|
KASSERT(d != NULL, ("gv_rename_drive: NULL d"));
|
|
|
|
if (gv_object_type(sc, newname) != -1) {
|
|
gctl_error(req, "drive name '%s' already in use", newname);
|
|
return (-1);
|
|
}
|
|
|
|
strncpy(d->name, newname, GV_MAXDRIVENAME);
|
|
strncpy(d->hdr->label.name, newname, GV_MAXDRIVENAME);
|
|
|
|
/* XXX can we rename providers here? */
|
|
|
|
LIST_FOREACH(s, &d->subdisks, from_drive)
|
|
strncpy(s->drive, d->name, GV_MAXDRIVENAME);
|
|
|
|
return (0);
|
|
}
|
|
|
|
static int
|
|
gv_rename_plex(struct gv_softc *sc, struct gctl_req *req, struct gv_plex *p, char *newname, int flags)
|
|
{
|
|
struct gv_sd *s;
|
|
char *plexnum, *plexnump, *oldplex, *oldplexp;
|
|
char *newsd, *oldsd, *oldsdp;
|
|
int err;
|
|
|
|
g_topology_assert();
|
|
KASSERT(p != NULL, ("gv_rename_plex: NULL p"));
|
|
|
|
err = 0;
|
|
|
|
if (gv_object_type(sc, newname) != -1) {
|
|
gctl_error(req, "plex name '%s' already in use", newname);
|
|
return (-1);
|
|
}
|
|
|
|
/* Needed for sanity checking. */
|
|
plexnum = g_malloc(GV_MAXPLEXNAME, M_WAITOK | M_ZERO);
|
|
strncpy(plexnum, newname, GV_MAXPLEXNAME);
|
|
plexnump = plexnum;
|
|
|
|
oldplex = g_malloc(GV_MAXPLEXNAME, M_WAITOK | M_ZERO);
|
|
strncpy(oldplex, p->name, GV_MAXPLEXNAME);
|
|
oldplexp = oldplex;
|
|
|
|
/*
|
|
* Locate the plex number part of the plex names.
|
|
*
|
|
* XXX: can we be sure that the current plex name has the format
|
|
* 'foo.pX'?
|
|
*/
|
|
strsep(&oldplexp, ".");
|
|
strsep(&plexnump, ".");
|
|
if (plexnump == NULL || *plexnump == '\0') {
|
|
gctl_error(req, "proposed plex name '%s' is not a valid plex "
|
|
"name", newname);
|
|
err = -1;
|
|
goto failure;
|
|
}
|
|
if (strcmp(oldplexp, plexnump)) {
|
|
gctl_error(req, "current and proposed plex numbers (%s, %s) "
|
|
"do not match", plexnump, oldplexp);
|
|
err = -1;
|
|
goto failure;
|
|
}
|
|
|
|
strncpy(p->name, newname, GV_MAXPLEXNAME);
|
|
|
|
/* XXX can we rename providers here? */
|
|
|
|
/* Fix up references and potentially rename subdisks. */
|
|
LIST_FOREACH(s, &p->subdisks, in_plex) {
|
|
strncpy(s->plex, p->name, GV_MAXPLEXNAME);
|
|
if (flags && GV_FLAG_R) {
|
|
newsd = g_malloc(GV_MAXSDNAME, M_WAITOK | M_ZERO);
|
|
oldsd = g_malloc(GV_MAXSDNAME, M_WAITOK | M_ZERO);
|
|
oldsdp = oldsd;
|
|
strncpy(oldsd, s->name, GV_MAXSDNAME);
|
|
/*
|
|
* XXX: can we be sure that the current sd name has the
|
|
* format 'foo.pX.sY'?
|
|
*/
|
|
strsep(&oldsdp, ".");
|
|
strsep(&oldsdp, ".");
|
|
snprintf(newsd, GV_MAXSDNAME, "%s.%s", p->name, oldsdp);
|
|
err = gv_rename_sd(sc, req, s, newsd, flags);
|
|
g_free(newsd);
|
|
g_free(oldsd);
|
|
if (err)
|
|
goto failure;
|
|
}
|
|
}
|
|
|
|
failure:
|
|
g_free(plexnum);
|
|
g_free(oldplex);
|
|
|
|
return (err);
|
|
}
|
|
|
|
/*
|
|
* gv_rename_sd: renames a subdisk. Note that the 'flags' argument is ignored,
|
|
* since there are no structures below a subdisk. Similarly, we don't have to
|
|
* clean up any references elsewhere to the subdisk's name.
|
|
*/
|
|
static int
|
|
gv_rename_sd(struct gv_softc *sc, struct gctl_req *req, struct gv_sd *s, char * newname, int flags)
|
|
{
|
|
char *new, *newp, *old, *oldp;
|
|
int err;
|
|
|
|
g_topology_assert();
|
|
KASSERT(s != NULL, ("gv_rename_sd: NULL s"));
|
|
|
|
err = 0;
|
|
|
|
if (gv_object_type(sc, newname) != -1) {
|
|
gctl_error(req, "subdisk name %s already in use", newname);
|
|
return (-1);
|
|
}
|
|
|
|
/* Needed for sanity checking. */
|
|
new = g_malloc(GV_MAXSDNAME, M_WAITOK | M_ZERO);
|
|
strncpy(new, newname, GV_MAXSDNAME);
|
|
newp = new;
|
|
|
|
old = g_malloc(GV_MAXSDNAME, M_WAITOK | M_ZERO);
|
|
strncpy(old, s->name, GV_MAXSDNAME);
|
|
oldp = old;
|
|
|
|
/*
|
|
* Locate the sd number part of the sd names.
|
|
*
|
|
* XXX: can we be sure that the current sd name has the format
|
|
* 'foo.pX.sY'?
|
|
*/
|
|
strsep(&oldp, ".");
|
|
strsep(&oldp, ".");
|
|
strsep(&newp, ".");
|
|
if (newp == NULL || *newp == '\0') {
|
|
gctl_error(req, "proposed sd name '%s' is not a valid sd name",
|
|
newname);
|
|
err = -1;
|
|
goto fail;
|
|
}
|
|
strsep(&newp, ".");
|
|
if (newp == NULL || *newp == '\0') {
|
|
gctl_error(req, "proposed sd name '%s' is not a valid sd name",
|
|
newname);
|
|
err = -1;
|
|
goto fail;
|
|
}
|
|
if (strcmp(newp, oldp)) {
|
|
gctl_error(req, "current and proposed sd numbers (%s, %s) do "
|
|
"not match", oldp, newp);
|
|
err = -1;
|
|
goto fail;
|
|
}
|
|
|
|
strncpy(s->name, newname, GV_MAXSDNAME);
|
|
|
|
/* XXX: can we rename providers here? */
|
|
|
|
fail:
|
|
g_free(new);
|
|
g_free(old);
|
|
|
|
return (err);
|
|
}
|
|
|
|
static int
|
|
gv_rename_vol(struct gv_softc *sc, struct gctl_req *req, struct gv_volume *v, char *newname, int flags)
|
|
{
|
|
struct gv_plex *p;
|
|
char *new, *old, *oldp;
|
|
int err;
|
|
|
|
g_topology_assert();
|
|
KASSERT(v != NULL, ("gv_rename_vol: NULL v"));
|
|
|
|
if (gv_object_type(sc, newname) != -1) {
|
|
gctl_error(req, "volume name %s already in use", newname);
|
|
return (-1);
|
|
}
|
|
|
|
/* Rename the volume. */
|
|
strncpy(v->name, newname, GV_MAXVOLNAME);
|
|
|
|
/* Fix up references and potentially rename plexes. */
|
|
LIST_FOREACH(p, &v->plexes, in_volume) {
|
|
strncpy(p->volume, v->name, GV_MAXVOLNAME);
|
|
if (flags && GV_FLAG_R) {
|
|
new = g_malloc(GV_MAXPLEXNAME, M_WAITOK | M_ZERO);
|
|
old = g_malloc(GV_MAXPLEXNAME, M_WAITOK | M_ZERO);
|
|
oldp = old;
|
|
strncpy(old, p->name, GV_MAXPLEXNAME);
|
|
/*
|
|
* XXX: can we be sure that the current plex name has
|
|
* the format 'foo.pX'?
|
|
*/
|
|
strsep(&oldp, ".");
|
|
snprintf(new, GV_MAXPLEXNAME, "%s.%s", v->name, oldp);
|
|
err = gv_rename_plex(sc, req, p, new, flags);
|
|
g_free(new);
|
|
g_free(old);
|
|
if (err)
|
|
return (err);
|
|
}
|
|
}
|
|
|
|