tc_counter_mask is an unsigned int and in the TSC timecounter is equal
to UINT_MAX, so the addition tc->tc_counter_mask + 1 can overflow to 0,
resulting in a hang during boot.
Fixes: c2705ceaeb
("x86: Speed up clock calibration")
Reviewed by: cperciva
Sponsored by: The FreeBSD Foundation
Differential Revision: https://reviews.freebsd.org/D33956
184 lines
6.3 KiB
C
184 lines
6.3 KiB
C
/*-
|
|
* Copyright (c) 2022 Colin Percival
|
|
* All rights reserved.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
|
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
|
|
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
* SUCH DAMAGE.
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
#include <sys/param.h>
|
|
#include <sys/systm.h>
|
|
#include <sys/timetc.h>
|
|
#include <sys/tslog.h>
|
|
#include <machine/cpu.h>
|
|
|
|
/**
|
|
* clockcalib(clk, clkname):
|
|
* Return the frequency of the provided timer, as calibrated against the
|
|
* current best-available timecounter.
|
|
*/
|
|
uint64_t
|
|
clockcalib(uint64_t (*clk)(void), const char *clkname)
|
|
{
|
|
struct timecounter *tc = atomic_load_ptr(&timecounter);
|
|
uint64_t clk0, clk1, clk_delay, n, passes = 0;
|
|
uint64_t t0, t1, tadj, tlast;
|
|
double mu_clk = 0;
|
|
double mu_t = 0;
|
|
double va_clk = 0;
|
|
double va_t = 0;
|
|
double cva = 0;
|
|
double d1, d2;
|
|
double inv_n;
|
|
uint64_t freq;
|
|
|
|
TSENTER();
|
|
/*-
|
|
* The idea here is to compute a best-fit linear regression between
|
|
* the clock we're calibrating and the reference clock; the slope of
|
|
* that line multiplied by the frequency of the reference clock gives
|
|
* us the frequency we're looking for.
|
|
*
|
|
* To do this, we calculate the
|
|
* (a) mean of the target clock measurements,
|
|
* (b) variance of the target clock measurements,
|
|
* (c) mean of the reference clock measurements,
|
|
* (d) variance of the reference clock measurements, and
|
|
* (e) covariance of the target clock and reference clock measurements
|
|
* on an ongoing basis, updating all five values after each new data
|
|
* point arrives, stopping when we're confident that we've accurately
|
|
* measured the target clock frequency.
|
|
*
|
|
* Given those five values, the important formulas to remember from
|
|
* introductory statistics are:
|
|
* 1. slope of regression line = covariance(x, y) / variance(x)
|
|
* 2. (relative uncertainty in slope)^2 =
|
|
* (variance(x) * variance(y) - covariance(x, y)^2)
|
|
* ------------------------------------------------
|
|
* covariance(x, y)^2 * (N - 2)
|
|
*
|
|
* We adjust the second formula slightly, adding a term to each of
|
|
* the variance values to reflect the measurement quantization.
|
|
*
|
|
* Finally, we need to determine when to stop gathering data. We
|
|
* can't simply stop as soon as the computed uncertainty estimate
|
|
* is below our threshold; this would make us overconfident since it
|
|
* would introduce a multiple-comparisons problem (cf. sequential
|
|
* analysis in clinical trials). Instead, we stop with N data points
|
|
* if the estimated uncertainty of the first k data points meets our
|
|
* target for all N/2 < k <= N; this is not theoretically optimal,
|
|
* but in practice works well enough.
|
|
*/
|
|
|
|
/*
|
|
* Initial values for clocks; we'll subtract these off from values
|
|
* we measure later in order to reduce floating-point rounding errors.
|
|
* We keep track of an adjustment for values read from the reference
|
|
* timecounter, since it can wrap.
|
|
*/
|
|
clk0 = clk();
|
|
t0 = tc->tc_get_timecount(tc) & tc->tc_counter_mask;
|
|
tadj = 0;
|
|
tlast = t0;
|
|
|
|
/* Loop until we give up or decide that we're calibrated. */
|
|
for (n = 1; ; n++) {
|
|
/* Get a new data point. */
|
|
clk1 = clk() - clk0;
|
|
t1 = tc->tc_get_timecount(tc) & tc->tc_counter_mask;
|
|
while (t1 + tadj < tlast)
|
|
tadj += (uint64_t)tc->tc_counter_mask + 1;
|
|
tlast = t1 + tadj;
|
|
t1 += tadj - t0;
|
|
|
|
/* If we spent too long, bail. */
|
|
if (t1 > tc->tc_frequency) {
|
|
printf("Statistical %s calibration failed! "
|
|
"Clocks might be ticking at variable rates.\n",
|
|
clkname);
|
|
printf("Falling back to slow %s calibration.\n",
|
|
clkname);
|
|
freq = (double)(tc->tc_frequency) * clk1 / t1;
|
|
break;
|
|
}
|
|
|
|
/* Precompute to save on divisions later. */
|
|
inv_n = 1.0 / n;
|
|
|
|
/* Update mean and variance of recorded TSC values. */
|
|
d1 = clk1 - mu_clk;
|
|
mu_clk += d1 * inv_n;
|
|
d2 = d1 * (clk1 - mu_clk);
|
|
va_clk += (d2 - va_clk) * inv_n;
|
|
|
|
/* Update mean and variance of recorded time values. */
|
|
d1 = t1 - mu_t;
|
|
mu_t += d1 * inv_n;
|
|
d2 = d1 * (t1 - mu_t);
|
|
va_t += (d2 - va_t) * inv_n;
|
|
|
|
/* Update covariance. */
|
|
d2 = d1 * (clk1 - mu_clk);
|
|
cva += (d2 - cva) * inv_n;
|
|
|
|
/*
|
|
* Count low-uncertainty iterations. This is a rearrangement
|
|
* of "relative uncertainty < 1 PPM" avoiding division.
|
|
*/
|
|
#define TSC_PPM_UNCERTAINTY 1
|
|
#define TSC_UNCERTAINTY TSC_PPM_UNCERTAINTY * 0.000001
|
|
#define TSC_UNCERTAINTY_SQR TSC_UNCERTAINTY * TSC_UNCERTAINTY
|
|
if (TSC_UNCERTAINTY_SQR * (n - 2) * cva * cva >
|
|
(va_t + 4) * (va_clk + 4) - cva * cva)
|
|
passes++;
|
|
else
|
|
passes = 0;
|
|
|
|
/* Break if we're consistently certain. */
|
|
if (passes * 2 > n) {
|
|
freq = (double)(tc->tc_frequency) * cva / va_t;
|
|
if (bootverbose)
|
|
printf("Statistical %s calibration took"
|
|
" %lu us and %lu data points\n",
|
|
clkname, (unsigned long)(t1 *
|
|
1000000.0 / tc->tc_frequency),
|
|
(unsigned long)n);
|
|
break;
|
|
}
|
|
|
|
/*
|
|
* Add variable delay to avoid theoretical risk of aliasing
|
|
* resulting from this loop synchronizing with the frequency
|
|
* of the reference clock. On the nth iteration, we spend
|
|
* O(1 / n) time here -- long enough to avoid aliasing, but
|
|
* short enough to be insignificant as n grows.
|
|
*/
|
|
clk_delay = clk() + (clk() - clk0) / (n * n);
|
|
while (clk() < clk_delay)
|
|
cpu_spinwait(); /* Do nothing. */
|
|
}
|
|
TSEXIT();
|
|