freebsd-nq/sys/net/if_vlan_var.h
Andre Oppermann 78ba57b9e1 Move ethernet VLAN tags from mtags to its own mbuf packet header field
m_pkthdr.ether_vlan.  The presence of the M_VLANTAG flag on the mbuf
signifies the presence and validity of its content.

Drivers that support hardware VLAN tag stripping fill in the received
VLAN tag (containing both vlan and priority information) into the
ether_vtag mbuf packet header field:

	m->m_pkthdr.ether_vtag = vlan_id;	/* ntohs()? */
	m->m_flags |= M_VLANTAG;

to mark the packet m with the specified VLAN tag.

On output the driver should check the mbuf for the M_VLANTAG flag to
see if a VLAN tag is present and valid:

	if (m->m_flags & M_VLANTAG) {
		... = m->m_pkthdr.ether_vtag;	/* htons()? */
		... pass tag to hardware ...
	}

VLAN tags are stored in host byte order.  Byte swapping may be necessary.

(Note: This driver conversion was mechanic and did not add or remove any
byte swapping in the drivers.)

Remove zone_mtag_vlan UMA zone and MTAG_VLAN definition.  No more tag
memory allocation have to be done.

Reviewed by:	thompsa, yar
Sponsored by:	TCP/IP Optimization Fundraise 2005
2006-09-17 13:33:30 +00:00

107 lines
3.6 KiB
C

/*-
* Copyright 1998 Massachusetts Institute of Technology
*
* Permission to use, copy, modify, and distribute this software and
* its documentation for any purpose and without fee is hereby
* granted, provided that both the above copyright notice and this
* permission notice appear in all copies, that both the above
* copyright notice and this permission notice appear in all
* supporting documentation, and that the name of M.I.T. not be used
* in advertising or publicity pertaining to distribution of the
* software without specific, written prior permission. M.I.T. makes
* no representations about the suitability of this software for any
* purpose. It is provided "as is" without express or implied
* warranty.
*
* THIS SOFTWARE IS PROVIDED BY M.I.T. ``AS IS''. M.I.T. DISCLAIMS
* ALL EXPRESS OR IMPLIED WARRANTIES WITH REGARD TO THIS SOFTWARE,
* INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
* MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT
* SHALL M.I.T. BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
* LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF
* USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND
* ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
* OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT
* OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
* $FreeBSD$
*/
#ifndef _NET_IF_VLAN_VAR_H_
#define _NET_IF_VLAN_VAR_H_ 1
struct ether_vlan_header {
u_char evl_dhost[ETHER_ADDR_LEN];
u_char evl_shost[ETHER_ADDR_LEN];
u_int16_t evl_encap_proto;
u_int16_t evl_tag;
u_int16_t evl_proto;
};
#define EVL_VLID_MASK 0x0FFF
#define EVL_VLANOFTAG(tag) ((tag) & EVL_VLID_MASK)
#define EVL_PRIOFTAG(tag) (((tag) >> 13) & 7)
/* sysctl(3) tags, for compatibility purposes */
#define VLANCTL_PROTO 1
#define VLANCTL_MAX 2
/*
* Configuration structure for SIOCSETVLAN and SIOCGETVLAN ioctls.
*/
struct vlanreq {
char vlr_parent[IFNAMSIZ];
u_short vlr_tag;
};
#define SIOCSETVLAN SIOCSIFGENERIC
#define SIOCGETVLAN SIOCGIFGENERIC
#ifdef _KERNEL
/*
* Drivers that are capable of adding and removing the VLAN header
* in hardware indicate they support this by marking IFCAP_VLAN_HWTAGGING
* in if_capabilities. Drivers for hardware that is capable
* of handling larger MTU's that may include a software-appended
* VLAN header w/o lowering the normal MTU should mark IFCAP_VLAN_MTU
* in if_capabilities; this notifies the VLAN code it can leave the
* MTU on the vlan interface at the normal setting.
*/
/*
* VLAN tags are stored in host byte order. Byte swapping may be
* necessary.
*
* Drivers that support hardware VLAN tag stripping fill in the
* received VLAN tag (containing both vlan and priority information)
* into the ether_vtag mbuf packet header field:
*
* m->m_pkthdr.ether_vtag = vlan_id; // ntohs()?
* m->m_flags |= M_VLANTAG;
*
* to mark the packet m with the specified VLAN tag.
*
* On output the driver should check the mbuf for the M_VLANTAG
* flag to see if a VLAN tag is present and valid:
*
* if (m->m_flags & M_VLANTAG) {
* ... = m->m_pkthdr.ether_vtag; // htons()?
* ... pass tag to hardware ...
* }
*
* Note that a driver must indicate it supports hardware VLAN
* stripping/insertion by marking IFCAP_VLAN_HWTAGGING in
* if_capabilities.
*/
#define VLAN_CAPABILITIES(_ifp) do { \
if ((_ifp)->if_vlantrunk != NULL) \
(*vlan_trunk_cap_p)(_ifp); \
} while (0)
extern void (*vlan_trunk_cap_p)(struct ifnet *);
#endif /* _KERNEL */
#endif /* _NET_IF_VLAN_VAR_H_ */