freebsd-nq/sys/dev/em
Robert Watson 13b203d0d7 Modify device drivers supporting multicast addresses to lock if_addr_mtx
over iteration of their multicast address lists when synchronizing the
hardware address filter with the network stack-maintained list.

Problem reported by:	Ed Maste (emaste at phaedrus dot sandvine dot ca>
MFC after:		1 week
2005-08-03 00:18:35 +00:00
..
if_em_hw.c Changes to update driver with latest Intel driver version 2.1.7 2005-05-26 23:32:02 +00:00
if_em_hw.h Changes to update driver with latest Intel driver version 2.1.7 2005-05-26 23:32:02 +00:00
if_em_osdep.h Changes to update driver with latest Intel driver version 2.1.7 2005-05-26 23:32:02 +00:00
if_em.c Modify device drivers supporting multicast addresses to lock if_addr_mtx 2005-08-03 00:18:35 +00:00
if_em.h Stop embedding struct ifnet at the top of driver softcs. Instead the 2005-06-10 16:49:24 +00:00
LICENSE Start each of the license/copyright comments with /*-, minor shuffle of lines 2005-01-06 01:43:34 +00:00
README Correct a minor typo. 2005-07-11 02:33:25 +00:00

$FreeBSD$
FreeBSD* Driver for the Intel(R) PRO/1000 Family of Adapters
============================================================

March 18, 2005


Contents
========

- Overview
- Identifying Your Adapter
- Building and Installation
- Speed and Duplex Configuration
- Additional Configurations
- Known Limitations
- Support
- License


Overview
========

This file describes the FreeBSD* driver, version 2.1.x, for the Intel(R)
PRO/1000 Family of Adapters. This driver has been developed for use with
FreeBSD, version 5.x.

For questions related to hardware requirements, refer to the documentation
supplied with your Intel PRO/1000 adapter. All hardware requirements listed
apply to use with FreeBSD.


Identifying Your Adapter
========================

For information on how to identify your adapter, go to the Adapter &
Driver ID Guide at:

http://support.intel.com/support/network/adapter/pro100/21397.htm


For the latest Intel network drivers for FreeBSD, see:

http://appsr.intel.com/scripts-df/support_intel.asp


NOTE: Mobile adapters are not fully supported.


Building and Installation
=========================

NOTE: The driver can be installed as a dynamic loadable kernel module or
      compiled into the kernel. You must have kernel sources installed in
      order to compile the driver module.

In the instructions below, x.x.x is the driver version as indicated in the
name of the driver tar file.

1. Move the base driver tar file to the directory of your choice. For
   example, use /home/username/em or /usr/local/src/em.

2. Untar/unzip the archive:

        tar xvfz em-x.x.x.tar.gz

   This will create an em-x.x.x directory.

3. To create a loadable module, perform the following steps.
   NOTE: To compile the driver into the kernel, go directly to step 4.

        a. To compile the module

                  cd em-x.x.x
                  make

        b. To install the compiled module in system directory:

                  make install

        c. If you want the driver to load automatically when the system is booted:

              1. Edit /boot/loader.conf, and add the following line:

                  if_em_load="YES"

4. To compile the driver into the kernel:

        cd em-x.x.x/src

        cp if_em* /usr/src/sys/dev/em

        cp Makefile.kernel /usr/src/sys/modules/em/Makefile

   Edit the /usr/src/sys/conf/files.i386 file, and add the following lines only if
   they don't already exist:

        dev/em/if_em.c optional em

        dev/em/if_em_hw.c optional em

   Remove the following lines from the /usr/src/sys/conf/files.i386 file,
   if they exist:

        dev/em/if_em_fxhw.c optional em
        dev/em/if_em_phy.c optional em

   Edit the kernel configuration file (i.e., GENERIC or MYKERNEL) in
   /usr/src/sys/i386/conf, and ensure the following line is present:

        device em

   Compile and install the kernel. The system must be rebooted for the kernel
   updates to take effect. For additional information on compiling the
   kernel, consult the FreeBSD operating system documentation.

5. To assign an IP address to the interface, enter the following:

        ifconfig em<interface_num> <IP_address>

6. Verify that the interface works. Enter the following, where <IP_address>
   is the IP address for another machine on the same subnet as the interface
   that is being tested:

        ping <IP_address>

7. To configure the IP address to remain after reboot, edit /etc/rc.conf,
   and create the appropriate ifconfig_em<interface_num>entry:

        ifconfig_em<interface_num>="<ifconfig_settings>"

   Example usage:

        ifconfig_em0="inet 192.168.10.1 netmask 255.255.255.0"

   NOTE: For assistance, see the ifconfig man page.


Speed and Duplex Configuration
==============================

By default, the adapter auto-negotiates the speed and duplex of the
connection. If there is a specific need, the ifconfig utility can be used to
configure the speed and duplex settings on the adapter. Example usage:

        ifconfig em<interface_num> <IP_address> media 100baseTX mediaopt
            full-duplex

   NOTE: Only use mediaopt to set the driver to full-duplex. If mediaopt is
         not specified and you are not running at gigabit speed, the driver
         defaults to half-duplex.


This driver supports the following media type options:

   autoselect      -  Enables auto-negotiation for speed and duplex.

   10baseT/UTP     -  Sets speed to 10 Mbps. Use the ifconfig mediaopt
                      option to select full-duplex mode.

   100baseTX       -  Sets speed to 100 Mbps. Use the ifconfig mediaopt
                      option to select full-duplex mode.

   1000baseTX      -  Sets speed to 1000 Mbps. In this case, the driver
                      supports only full-duplex mode.

   1000baseSX      -  Sets speed to 1000 Mbps. In this case, the driver
                      supports only full-duplex mode.

For more information on the ifconfig utility, see the ifconfig man page.


Additional Configurations
=========================

The driver supports Transmit/Receive Checksum Offload and Jumbo Frames on
all but the 82542-based adapters. For specific adapters, refer to the
Identifying Your Adapter section.

  Jumbo Frames
  ------------
  To enable Jumbo Frames, use the ifconfig utility to increase the MTU
  beyond 1500 bytes.

  NOTES: Only enable Jumbo Frames if your network infrastructure supports
         them.

         The Jumbo Frames setting on the switch must be set to at least
         22 bytes larger than that of the MTU.

         The Intel PRO/1000 PM Network Connection does not support jumbo
         frames.


  The Jumbo Frames MTU range for Intel Adapters is 1500 to 16114. The default
  MTU range is 1500. To modify the setting, enter the following:

        ifconfig em<interface_num> <hostname or IP address> mtu 9000

 To confirm the MTU used between two specific devices, use:

        route get <destination_IP_address>

  VLANs
  -----
  To create a new VLAN interface:

        ifconfig <vlan_name> create

  To associate the VLAN interface with a physical interface and
  assign a VLAN ID, IP address, and netmask:

        ifconfig <vlan_name> <ip_address> netmask <subnet_mask> vlan
           <vlan_id> vlandev <physical_interface>

  Example:

        ifconfig vlan10 10.0.0.1 netmask 255.255.255.0 vlan10 vlandev em0

  In this example, all packets will be marked on egress with  802.1Q VLAN
  tags, specifying a VLAN ID of 10.

  To remove a VLAN interface:

        ifconfig <vlan_name> destroy

  Polling
  -------
  NOTES: DEVICE POLLING is only valid for non-SMP kernels.

        The driver has to be compiled into the kernel for DEVICE POLLING to be
        enabled in the driver.

  To enable polling in the driver, add the following options to the kernel
  configuration, and then recompile the kernel:

        options DEVICE_POLLING
        options HZ=1000

  At runtime use:
        sysctl kern.polling.enable=1 to turn polling on
  Use:
        sysctl kern.polling.enable=0 to turn polling off

  Checksum Offload
  ----------------
  Checksum offloading is not supported on 82542 Gigabit adapters.

  Checksum offloading supports both TCP and UDP packets and is
  supported for both transmit and receive.

  Checksum offloading can be enabled or disabled using ifconfig.
  Both transmit and receive offloading will be either enabled or
  disabled together. You cannot enable/disable one without the other.

  To enable checksum offloading:

         ifconfig <interface_num> rxcsum

  To disable checksum offloading:

         ifconfig <interface_num> -rxcsum

  To confirm the current setting:

         ifconfig <interface_num>

  Look for the presence or absence of the following line:

         options=3 <RXCSUM,TXCSUM>

  See the ifconfig man page for further information.

Known Limitations
=================

  There are known performance issues with this driver when running UDP traffic
  with Jumbo Frames.

  There is a known compatibility issue where time to link is slow or link is not
  established between 82541/82547 controllers and some switches.  Known switches
  include:
        Planex FXG-08TE
        I-O Data ETG-SH8

  The driver can be compiled with the following changes:

  Edit ./em.x.x.x/src/if_em.h to uncomment the #define EM_MASTER_SLAVE
  from within the comments.  For example, change from:

      /* #define EM_MASTER_SLAVE  2 */
  to:
      #define EM_MASTER_SLAVE  2

  Use one of the following options:
      1 = Master mode
      2 = Slave mode
      3 = Auto master/slave
  Setting 2 is recommended.

  Recompile the module:
          a. To compile the module
                cd em-x.x.x
                make clean
                make

   b. To install the compiled module in system directory:
                make install


Support
=======

For general information and support, go to the Intel support website at:

        http://support.intel.com

If an issue is identified, support is through email only at:
freebsdnic@mailbox.intel.com

License
=======

This software program is released under the terms of a license agreement
between you ('Licensee') and Intel. Do not use or load this software or any
associated materials (collectively, the 'Software') until you have carefully
read the full terms and conditions of the LICENSE located in this software
package. By loading or using the Software, you agree to the terms of this
Agreement. If you do not agree with the terms of this Agreement, do not
install or use the Software.

* Other names and brands may be claimed as the property of others.