freebsd-nq/etc/gettytab
Ed Schouten 248389c80f Partially revert the change to the gettytab made in r198214.
By misinterpreting some data, I thought that getty wouldn't apply any
baud rate to the syscons devices, but it uses the default entry instead.
This means that the baud rate is set to 1200. This isn't too bad, except
when using canonical mode. Make it use 9600 baud by default.

MFC after:	1 week
2009-10-19 11:10:44 +00:00

234 lines
5.9 KiB
Plaintext

# $FreeBSD$
# from: @(#)gettytab 5.14 (Berkeley) 3/27/91
#
# Most of the table entries here are just copies of the old getty table,
# it is by no means certain, or even likely, that any of them are optimal
# for any purpose whatever. Nor is it likely that more than a couple are
# even correct.
#
# The default gettytab entry, used to set defaults for all other
# entries, and in cases where getty is called with no table name.
#
# cb, ce and ck are desirable on most crt's. The non-crt entries need to
# be changed to turn them off (:cb@:ce@:ck@:).
#
# lc should always be on; it's a remainder of some stone age when there
# have been terminals around not being able of handling lower-case
# characters. Those terminals aren't supported any longer, but getty is
# `smart' about them by default.
#
# Parity defaults to even, but the Pc entry and all the `std' entries
# specify no parity. The different parities are:
# (none): same as ep for getty. login will use terminal as is.
# ep: getty will use raw mode (cs8 -parenb) (unless rw is set) and
# fake parity. login will use even parity (cs7 parenb -parodd).
# op: same as ep except odd parity (cs7 parenb parodd) for login.
# getty will fake odd parity as well.
# ap: same as ep except -inpck instead of inpck for login.
# ap overrides op and ep.
# np: 1. don't fake parity in getty. The fake parity garbles
# characters on non-terminals (like pccons) that don't
# support parity. It would probably better for getty not to
# try to fake parity. It could just use cbreak mode so as
# not to force cs8 and let the hardware handle the parity.
# login has to be rely on the hardware anyway.
# 2. set cs8 -parenb -istrip -inpck.
# ep:op: same as ap.
#
default:\
:cb:ce:ck:lc:fd#1000:im=\r\n%s/%m (%h) (%t)\r\n\r\n:sp#1200:\
:if=/etc/issue:
#
# Fixed speed entries
#
# The "std.NNN" names are known to the special case
# portselector code in getty, however they can
# be assigned to any table desired.
# The "NNN-baud" names are known to the special case
# autobaud code in getty, and likewise can
# be assigned to any table desired (hopefully the same speed).
#
a|std.110|110-baud:\
:np:nd#1:cd#1:uc:sp#110:
b|std.134|134.5-baud:\
:np:nd#1:cd#2:ff#1:td#1:sp#134:ht:nl:
1|std.150|150-baud:\
:np:nd#1:cd#2:td#1:fd#1:sp#150:ht:nl:lm=\E\72\6\6\17login\72 :
c|std.300|300-baud:\
:np:nd#1:cd#1:sp#300:
d|std.600|600-baud:\
:np:nd#1:cd#1:sp#600:
f|std.1200|1200-baud:\
:np:fd#1:sp#1200:
6|std.2400|2400-baud:\
:np:sp#2400:
7|std.4800|4800-baud:\
:np:sp#4800:
2|std.9600|9600-baud:\
:np:sp#9600:
g|std.19200|19200-baud:\
:np:sp#19200:
std.38400|38400-baud:\
:np:sp#38400:
std.57600|57600-baud:\
:np:sp#57600:
std.115200|115200-baud:\
:np:sp#115200:
std.230400|230400-baud:\
:np:sp#230400:
#
# Entry specifying explicit device settings. See termios(4) and
# /usr/include/termios.h, too. The entry forces the tty into
# CLOCAL mode (so no DCD is required), and uses Xon/Xoff flow control.
#
# cflags: CLOCAL | HUPCL | CREAD | CS8
# oflags: OPOST | ONLCR | OXTABS
# iflags: IXOFF | IXON | ICRNL | IGNPAR
# lflags: IEXTEN | ICANON | ISIG | ECHOCTL | ECHO | ECHOK | ECHOE | ECHOKE
#
# The `0' flags don't have input enabled. The `1' flags don't echo.
# (Echoing is done inside getty itself.)
#
local.9600|CLOCAL tty @ 9600 Bd:\
:c0#0x0000c300:c1#0x0000cb00:c2#0x0000cb00:\
:o0#0x00000007:o1#0x00000002:o2#0x00000007:\
:i0#0x00000704:i1#0x00000000:i2#0x00000704:\
:l0#0x000005cf:l1#0x00000000:l2#0x000005cf:\
:sp#9600:
#
# Dial in rotary tables, speed selection via 'break'
#
0|d300|Dial-300:\
:nx=d1200:cd#2:sp#300:
d1200|Dial-1200:\
:nx=d150:fd#1:sp#1200:
d150|Dial-150:\
:nx=d110:lm@:tc=150-baud:
d110|Dial-110:\
:nx=d300:tc=300-baud:
#
# Fast dialup terminals, 2400/1200/300 rotary (can start either way)
#
D2400|d2400|Fast-Dial-2400:\
:nx=D1200:tc=2400-baud:
3|D1200|Fast-Dial-1200:\
:nx=D300:tc=1200-baud:
5|D300|Fast-Dial-300:\
:nx=D2400:tc=300-baud:
#
#telebit (19200)
#
t19200:\
:nx=t2400:tc=19200-baud:
t2400:\
:nx=t1200:tc=2400-baud:
t1200:\
:nx=t19200:tc=1200-baud:
#
#telebit (9600)
#
t9600:\
:nx=t2400a:tc=9600-baud:
t2400a:\
:nx=t1200a:tc=2400-baud:
t1200a:\
:nx=t9600:tc=1200-baud:
#
# Odd special case terminals
#
-|tty33|asr33|Pity the poor user of this beast:\
:tc=110-baud:
4|Console|Console Decwriter II:\
:nd@:cd@:rw:tc=300-baud:
e|Console-1200|Console Decwriter III:\
:fd@:nd@:cd@:rw:tc=1200-baud:
i|Interdata console:\
:uc:sp#0:
l|lsi chess terminal:\
:sp#300:
X|Xwindow|X window system:\
:fd@:nd@:cd@:rw:sp#9600:
P|Pc|Pc console:\
:ht:np:sp#9600:
#
# Wierdo special case for fast crt's with hardcopy devices
#
8|T9600|CRT with hardcopy:\
:nx=T300:tc=9600-baud:
9|T300|CRT with hardcopy (300):\
:nx=T9600:tc=300-baud:
#
# Plugboard, and misc other terminals
#
plug-9600|Plugboard-9600:\
:pf#1:tc=9600-baud:
p|P9600|Plugboard-9600-rotary:\
:pf#1:nx=P300:tc=9600-baud:
q|P300|Plugboard-300:\
:pf#1:nx=P1200:tc=300-baud:
r|P1200|Plugboard-1200:\
:pf#1:nx=P9600:tc=1200-baud:
#
# XXXX Port selector
#
s|DSW|Port Selector:\
:ps:sp#2400:
#
# Auto-baud speed detect entry for Micom 600.
# Special code in getty will switch this out
# to one of the NNN-baud entries.
#
A|Auto-baud:\
:ab:sp#2400:f0#040:
#
# autologin - automatically log in as root
#
autologin|al.9600:\
:al=root:tc=std.9600:
al.19200:\
:al=root:tc=std.19200:
al.38400:\
:al=root:tc=std.38400:
al.57600:\
:al=root:tc=std.57600:
al.115200:\
:al=root:tc=std.115200:
al.230400:\
:al=root:tc=std.230400:
#
# Entries for 3-wire serial terminals. These don't supply carrier, so
# clocal needs to be set, and crtscts needs to be unset.
#
3wire.9600|9600-3wire:\
:np:nc:sp#9600:
3wire.19200|19200-3wire:\
:np:nc:sp#19200:
3wire.38400|38400-3wire:\
:np:nc:sp#38400:
3wire.57600|57600-3wire:\
:np:nc:sp#57600:
3wire.115200|115200-3wire:\
:np:nc:sp#115200:
3wire.230400|230400-3wire:\
:np:nc:sp#230400: