Andrew Thompson c8a14b9124 EHCI Hardware BUG workaround
The EHCI HW can use the qtd_next field instead of qtd_altnext when a short
packet is received. This contradicts what is stated in the EHCI datasheet.
Also the total-bytes field in the status field of the following TD gets
corrupted upon reception of a short packet!  We work this around in software by
not queueing more than one job/TD at a time of up to 16Kbytes! The bug has been
seen on multiple INTEL based EHCI chips.  Other vendors have not been tested
yet.